")}("width","220px",["/lib/bootstrap-select/css/bootstrap-select.min.css"],"rel=\u0022stylesheet\u0022 ");
In the Mid 1980s GE changed it's 16cyl FDL design to include a different exhaust silencer, a new electric compressor often known as the "Whoop compressor" and changed some of the electronics of their locomotives. These differences among a few other led to a distinct change in the sounds from the GE 16cyl FDL often found from the U25Bs on through the Dash-7 series of the Locomotives.
GE's AC series of locomotives were introducted in 1994. They share the same carbody design and many of the internal components as the Dash-9 series, except they are equipped with AC traction motors instead of the conventional DC versions. The cab air conditioner was moved from the left (conductor's) side walkway to a position under the cab floor to make space for the six traction inverters (one per axle) that supply the AC current to the traction motors.
The "Modern" GE 7FDL 16Cyl Prime mover can be found in the following Locos:
Dash 8-39B, Dash 8 40-B, Dash 8-40BW, Dash 8-39C, Dash 8-40C, Dash 8-40CM, Dash 8-40CW, Dash 8-41CW, Dash 8-44CW, Dash 9-40C, Dash 9-40CW, Dash 9-44CW, C38EMi, C38AChe, AC4400CW
Some AC6000CW were built with 7FDL-16cyls and were later converted to 7HDL-16cyl. Some were never converted. Please refer to the prototype for reference.
Passenger Locos including: P40DC, and P42DC were built slightly different and contained HEP.
Recorded from a GE AC4400CW
This project has an automatic low & high idle. It has a single late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
3rd Generation Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie RS-3L
CV163=1 Leslie RS-5T-RRO
CV163=2 Nathan K-2H
CV163=3 Nathan K-3HL
CV163=4 Nathan K-3L
CV163=5 Nathan K-3LA
CV163=6 Nathan K-5HL-R2
CV163=7 Nathan K-5H-R24
CV163=8 Nathan K-5L
CV163=9 Nathan K-5LA
CV163=10 Nathan K-5LA-R24
CV163=11 Nathan K-5LLA-R1L
CV163=12 Nathan K-5L-R24
CV163=13 Nathan P-3
CV163=14 Nathan P-5-R24
GE Modern Bell Template Pack 2
Bells (SoundCV10):
CV164=0 GE M 6731022A Steel Bell 031
CV164=1 GE M 6731022A Steel Bell 033
CV164=2 Graham-White E-Bell 001
CV164=3 Graham-White E-Bell 002
CV164=4 Graham-White E-Bell 008
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2
GE Modern Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 AC4400CW Air Dryer 1
CV166=1 AC4400CW Air Dryer 2
CV166=2 AC4400CW Air Dryer 3
CV166=3 E4C6T Air Dryer 1
S0540 - Release Notes
===================================================
V-5 R-5:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- new traction motor AC motor
V-6 R-6:
==============
- New Prime Mover Volume Mode
- Correct Dynamic Brake Using Normal Idle Instead Of High Idle Hide description more…
The ALCO 251 prime mover was the most popular and abundant prime mover ever made by the company. While it proved to be quite successful, it sadly outlived its original manufacturer, ALCO who closed their doors in 1969. The 251 prime mover is actually still available to purchase today from Fairbanks Morse for use in Marine, Generator, and locomotive uses.
The 1800 horsepower 12cyl version of the 251B could be found in the following locomotives:
RS-11, RSD-12, RS-18, RS-36, FPA-4, FPB-4, RSC-14, FD-6, FD-7, FD-9, RSD-16, DL-560, 44 Class, 930 Class
The 2000 Horsepower 12cyl 251C version was extremely close to 251B in the way that is sounded. While we have full intentions to record this in the very near future the 251B is a very suitable substitute. The 12cyl 251C can be found in the following Locomotives:
RS-32, C420, M420, M420B, M420R, M420TR, HR-412, M424, 45 Class, 442 Class, 600 Class, 700 Class, A-321
The 12cyl 251 was also used in many rebuilt locomotives including:
RS-3m, C424m and others...
Recorded from a MLW RS-18U
This project is a normal idle version. It has a single exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
1st Generation Horn Pack 3
Horns (SoundCV9):
CV163=0 Leslie S-3K-R
CV163=1 Leslie S-3L-R
CV163=2 Leslie S-5T-RRO-R
CV163=3 Leslie SU-3L-R (Temp Leslie S-3L-R)
CV163=4 Nathan K-3H
CV163=5 Nathan K-3L
CV163=6 Nathan K-3LA
CV163=7 Nathan K-5H
CV163=8 Nathan K-5LA-R23
CV163=9 Nathan K-5LA-R24
CV163=10 Nathan P-2 (Temp Nathan P-3)
CV163=11 Nathan P-3
CV163=12 Nathan P-5
CV163=13 Nathan P-5A
CV163=14 Nathan P-5-R24
ALCO Bell Template Pack 2
Bells (SoundCV10):
CV164=0 ALCO Bronze Bell 001
CV164=1 ALCO Bronze Bell 002
CV164=2 ALCO Bronze Bell 008
CV164=3 ALCO Bronze Bell 011
CV164=4 Transtronic E-Bell 001
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
Switcher Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Cast Iron Shoe #1
ALCO Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 S-1 Air Dryer 1
CV166=1 C-425 Air Dryer 1
CV166=2 RS-18 Air Dryer 1
CV166=3 RS-18 Air Dryer 2 Hide description more…
The EMD 645 family of diesel engines were designed and manufactured by the Electro-Motive Division of General Motors. The 645 series was an evolution of the earlier 567 series and a precursor to the later 710 series. The 645 series engines entered production in 1965. All 645 engines utilize forced induction, with either a Roots blower or a turbocharger. The 645 series has a maximum engine speed of between 900 and 950 revolutions per minute (rpm), an increase over the 800 to 900 rpm maximum speed for the 567 series.
Our 12cyl 645E variation is appropriate for the following locomotives:
GP15-1, GP15AC, SW-1500, SW-1504, MP15AC, MP15DC
Recorded from a EMD GP15-1
This project is a normal idle version. It has 2 exhaust stacks.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
2nd Gen Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie S-3K-R
CV163=1 Leslie S-3L-R
CV163=2 Leslie S-5T-F
CV163=3 Leslie S-5T-R
CV163=4 Nathan K-3H
CV163=5 Nathan K-3L
CV163=6 Nathan K-3LA
CV163=7 Nathan K-5H
CV163=8 Nathan K-5LA
CV163=9 Nathan K-5LA-R24
CV163=10 Nathan M-3
CV163=11 Nathan M-3H
CV163=12 Nathan P-3
CV163=13 Nathan P-5-R24
EMD 2nd Generation Bell Template Pack 3
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 057
CV164=1 EMD 8004156 Bronze Bell 005
CV164=2 EMD 8004156 Bronze Bell 039
CV164=3 EMD 8475495 Steel Bell 059
CV164=4 EMD 8004156 Bronze Bell 045
CV164=5 UKM B443 Steel Bell 004
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV166=1 Cast Iron Shoe
EMD 2nd Generation Air Dryer Template Pack 7
Air Dryer (SoundCV12)
CV166=0 GP15-1 Air Dryer 1
CV166=1 GP15-1 Air Dryer 2
CV166=2 GP15-1 Air Dryer 3
CV166=3 GP15-1 Air Dryer 4 Hide description more…
The GE 44-ton switcher is a 4-axle diesel-electric locomotive built by General Electric between 1940 and 1956. The locomotives were available with a choice of prime movers. Most were built with a pair of Caterpillar Inc.'s D17000 V8 180 horsepower (134 kW) engines. It was designed for industrial and light switching duties, often replacing steam locomotives that had previously been assigned these chores. This locomotive's specific 44-short ton weight was directly related to one of the efficiencies the new diesel locomotives offered compared to their steam counterparts: reduced labour intensity. In the 1940s, the steam to diesel transition was in its infancy in North America, and railroad unions were trying to protect the locomotive fireman jobs that were redundant with diesel units. One measure taken to this end was a stipulation that locomotives weighing 90,000 pounds (41,000 kg) or more required a fireman in addition to an engineer. The 44-ton locomotive was born to skirt this requirement. Other manufacturers also built 44-ton switchers of center-cab configuration. 348 examples of this locomotive were built for North American railroads. Many remain, in service and in museums.
Recorded from a GE 44-Tonner
This project is a normal idle version. It is an air throttle version. It has a single exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
1st Generation Switcher Horn Pack 1
Horns (SoundCV9):
CV163=0 Handcock 4700 Whistle (Temp No Loop)
CV163=1 Leslie A-125
CV163=2 Leslie A-200
CV163=3 Leslie S-25 (Temp Leslie S-2M)
CV163=4 Leslie S-2M
CV163=5 Leslie S-3K
CV163=6 Leslie S-3L
CV163=7 Nathan M-3
CV163=8 Nathan M-5
CV163=9 Nathan P-2 (Temp Nathan P-3-OC)
CV163=10 Nathan P-3-OC
CV163=11 Nathan P-5-OC
CV163=12 Wabco A2
CV163=13 Wabco AA-2 (Temp Wabco A2)
CV163=14 Wabco E-2
GE Switcher Auto Bell On/Off Trigger Template Pack 1
Bells (SoundCV10):
CV164=0 GE 45-Tonner Air Bell
CV164=1 GE M 6731022A Steel Bell 017
CV164=2 GE M 6731022A Steel Bell 027
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
Switcher Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Cast Iron Shoe #1
ALCO Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 S-1 Air Dryer 1
CV166=1 C-425 Air Dryer 1
CV166=2 RS-18 Air Dryer 1
CV166=3 RS-18 Air Dryer 2 Hide description more…
Baldwin 606SC and 606A Prime Movers were used in quite a few Baldwin prototypes.
DS-4-4-1000, RS-12, S-12, DRS-6-4-1000, DRS-4-4-1000, DR-6-2-1000, DT-6-6-2000, RT-624, DR-6-4-2000, DR-6-2-1000.
Though not quite correct the 606SC/606A Prime Mover sounds very similar to the 608SC/608A Prime movers This would be appropriate for:
DRS-6-4-1500, DRS-4-4-1500, DRS-6-6-1500, AS-416, AS-16, AS-616, DR-6-4-1500, DR-4-4-1500 and the RF-16(Sharknose).
Recorded from a BLW DS-4-4-1000-SC
This project is a normal idle version. It is an air throttle version. It has a single exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
1st Gen Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie A-125
CV163=1 Leslie A-200
CV163=2 Leslie S-2M
CV163=3 Leslie S-3K
CV163=4 Leslie S-3L
CV163=5 Leslie S-5T
CV163=6 Nathan M3
CV163=7 Nathan M3H
CV163=8 Nathan M5
CV163=9 Nathan P5 (Old Cast)
CV163=10 Nathan P5R24 (Old Cast)
CV163=11 Nathan P3 (Old Cast)
CV163=12 Nathan P3-R4 (Old Cast)
CV163=13 Nathan P5A (Old Cast)
CV163=14 Wabco E-2
Baldwin Bell Template Pack 1
Bells (SoundCV10):
CV164=0 Baldwin Brass Bell 001
CV164=1 UKM B443 Steel Bell 005
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
Switcher Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Cast Iron Shoe #1
ALCO Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 S-1 Air Dryer 1
CV166=1 C-425 Air Dryer 1
CV166=2 RS-18 Air Dryer 1
CV166=3 RS-18 Air Dryer 2 Hide description more…
The SD50 was produced in response to increasingly tough competition from GE Transportation Systems, whose Dash 7 line was proving quite successful with railroads. While EMD's SD40-2 was a reliable and trusted product, GE's line included locomotives up to 3,600 hp (2,685 kW) with more modern technology, as well as very competitive finance and maintenance deals. EMD responded throughout the SD50 program by offering discounts on large orders.
GM-EMD had previously produced 3,600 hp (2,685 kW) locomotives, the SD45 and later SD45-2, but these used huge, 20-cylinder engines with high fuel consumption, and had reliability problems when first introduced. Demand for the 45 series dropped sharply after the 1970s fuel crisis. The SD50 used an updated version of the V16 645 used in the SD40-2, uprated to 3,500 hp (2,600 kW)- and later 3,600 hp (2,685 kW) - at 950 rpm from 3,000 hp (2,240 kW) at 900 rpm. This proved to be a step too far; the 50 series models were plagued by engine and electrical system problems which harmed both sales and the reputation of EMD.
While Recorded from an SD50, the EMD 16cyl 645F3B prime mover would also work for:
SD50, GP50, SD50S, SD50F
and it would be close to the 12cyl version of the 645F used the GP49.
Recorded from an SD50M
This project has a notch based low idle. It has a single late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
2nd Generation Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie S-3K-R
CV163=1 Leslie RS-3L-R
CV163=2 Leslie S-5T-F
CV163=3 Leslie S-5T-R
CV163=4 Nathan K-3H
CV163=5 Nathan K-3L
CV163=6 Nathan K-3LA
CV163=7 Nathan K-5H
CV163=8 Nathan K-5LA
CV163=9 Nathan K-5LA-R24
CV163=10 Nathan M-3
CV163=11 Nathan M-3H
CV163=12 Nathan P-3
CV163=13 Nathan P-5-R24
EMD 2nd Generation Bell Template Pack 3
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 057
CV164=1 EMD 8004156 Bronze Bell 005
CV164=2 EMD 8004156 Bronze Bell 039
CV164=3 EMD 8475495 Steel Bell 059
CV164=4 EMD 8004156 Bronze Bell 045
CV164=5 UKM B443 Steel Bell 004
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV165=1 Cast Iron Shoe
EMD 2nd Generation Air Dryer Template Pack 6
Air Dryer (SoundCV12)
CV166=0 SD50M Air Dryer 1
CV166=1 SD50M Air Dryer 2
CV166=2 SD50 Air Dryer 1
CV166=3 GP50 Air Dryer 1
S0550 - Release Notes
===================================================
V-5 R-5:
===================================================
- Prime mover volume selection mode
Hide description more…
The EMD SW7 was a diesel switcher locomotive built by General Motors Electro-Motive Division between October 1949 and January 1951. It was powered by a 1,200 horsepower 12-567A engine. The SW7 replaced the earlier 1,000 horsepower NW2 switcher in EMD's catalog. A total of 489 SW7 locomotives were produced. The majority of the SW7s were built by EMD Plant #3 in Cleveland, Ohio. In addition, 15 TR4 cow-calf paired sets were produced.
SW7 production was discontinued in 1951 in favor of the new SW9.
Even though the SW7 was originally fitted with a 12-567A prime mover, this engine had the orignal prime mover replaced with a 12-567C. This happened to some SW7's over the years, as others types were rebuilt into 12-567AC's.
Recorded from a EMD SW7
This project is a normal idle version. It is an air throttle version. It has switcher type exhaust with 2 exhaust stacks.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
1st Generation Switcher Horn Pack 2
Horns (SoundCV9):
CV163=0 Leslie S-25
CV163=1 Leslie S-31
CV163=2 Leslie A-75
CV163=3 Leslie A-125
CV163=4 Leslie A-200
CV163=5 Leslie RS-25
CV163=6 Leslie RS-31
CV163=7 Wabco E-2
CV163=8 Wabco A-2
CV163=9 Wabco AA-2
CV163=10 Leslie A-75 Ed2
CV163=11 Leslie A-125 Ed2
CV163=12 Leslie A-200 Ed2
CV163=13 Wabco E-2 Ed2
CV163=14 Leslie S-2M Ed2
CV163=15 Leslie S-2B
EMD 1st Generation Switcher Bell Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8004156 Bronze Bell 007
CV164=1 EMD 8475495 Steel Bell 011
CV164=2 EMD 8004156 Bronze Bell 008
CV164=3 EMD 8475495 Steel Bell 034
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
Switcher Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Cast Iron Shoe #1
EMD 1st Generation Switcher Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 NW2 Air Dryer 1
CV166=1 NW5 Air Dryer 1
CV166=2 SW7 Air Dryer 1
CV166=3 SW10 Air Dryer 1
S0560 - Release Notes
===================================================
V-2 R-2:
===================================================
- New Prime Mover Volume Mode Hide description more…
The 567 prime mover is a line of medium-speed diesel engines manufactured by GM Electro-Motive Division. They were used in many EMD locomotives from 1938-1966 when it was replaced by the EMD 645. The 567 proved to be exceptionally successful in passenger, switching, freight, marine and stationary services. The 16 cylinder 567D3 variation was used in the following...
Locomotives:
GP30, SD24
Although the following locomotives do not have a 567D3, they are in the 567D family and this sound file would be very close for the following...
GP20, GP35, SD35, SDP35
Recorded from a EMD SD24
This project is a normal idle version. It has a single turbo early exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
1st Gen Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie A-125
CV163=1 Leslie A-200
CV163=2 Leslie S-2M
CV163=3 Leslie S-3K
CV163=4 Leslie S-3L
CV163=5 Leslie S-5T
CV163=6 Nathan M3
CV163=7 Nathan M3H
CV163=8 Nathan M5
CV163=9 Nathan P5 (Old Cast)
CV163=10 Nathan P5R24 (Old Cast)
CV163=11 Nathan P3 (Old Cast)
CV163=12 Nathan P3-R4 (Old Cast)
CV163=13 Nathan P5A (Old Cast)
CV163=14 Wabco E-2
EMD 1st Generation Bell Template Pack 3
Bells (SoundCV10):
CV164=0 EMD 8004156 Bronze Bell 014
CV164=1 EMD 8475495 Steel Bell 013
CV164=2 EMD 8004156 Bronze Bell 015
CV164=3 EMD 8475495 Steel Bell 024
CV164=4 EMD 8475495 Steel Bell 028
CV164=5 Graham-White E-Bell 005
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
1st Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV166=1 Cast Iron Shoe
EMD 1st Generation Air Dryer Template Pack 3
Air Dryer (SoundCV12)
CV166=0 GP30 Air Dryer 1
CV166=1 GP30M Air Dryer 2
CV166=1 GP30M Air Dryer 1
CV166=1 SD24 Air Dryer 1 Hide description more…
First made in the late 1930's the EMD 12cyl 567 Prime Movers were the power houses in many of EMD's Switchers. At the same time EMD found they could put 2 of these Prime movers together in one carbody to create a more powerful locomotive. Often geared for passenger service the E Units were created.
Locomotives:
E3
E4
E5
E6
E7
E8
E9
1st Generation Horn Template Pack 1
Horns (SoundCV9):
CV163=0 Leslie A-125
CV163=1 Leslie A-200
CV163=2 Leslie S-2M
CV163=3 Leslie S-3K
CV163=4 Leslie S-3L
CV163=5 Leslie S-5T
CV163=6 Nathan M3
CV163=7 Nathan M3H
CV163=8 Nathan M5
CV163=9 Nathan P5 (Old Cast)
CV163=10 Nathan P5R24 (Old Cast)
CV163=11 Nathan P3 (Old Cast)
CV163=12 Nathan P3-R4 (Old Cast)
CV163=13 Nathan P5A (Old Cast)
CV163=14 Wabco E-2
EMD 1st Generation Bell Template Pack 3
Bells (SoundCV10):
CV164=0 EMD 8004156 Bronze Bell 014
CV164=1 EMD 8475495 Steel Bell 013
CV164=2 EMD 8004156 Bronze Bell 015
CV164=3 EMD 8475495 Steel Bell 024
CV164=4 EMD 8475495 Steel Bell 028
CV164=5 Graham-White E-Bell 005
1st Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV166=1 Cast Iron Shoe
FULL THROTTLE features:
Drive Hold: Sound Slot 2 Mapped to F9
Independent Brake: Sound Slot 11 Mapped to F10
Run 8: Sound Slot 20 (not Mapped)
Coast: Sound Slot 21 (not Mapped) Hide description more…
Budd RDC
Detroit Diesel Dual 6cyl Prime Movers
The Budd Rail Diesel Car, RDC or Buddliner is a self-propelled diesel multiple unit (DMU) railcar. Between 1949 and 1962, 398 RDCs were built by the Budd Company of Philadelphia, Pennsylvania, United States. The cars were primarily adopted for passenger service in rural areas with low traffic density or in short-haul commuter service, and were less expensive to operate in this context than a traditional diesel locomotive-drawn train with coaches. The cars could be used singly or coupled together in train sets and controlled from the cab of the front unit. The RDC was one of the few DMU trains to achieve commercial success in North America. RDC trains were an early example of self-contained diesel multiple unit trains, an arrangement now in common use by railways all over the world.
Budd RDCs were sold to operators in North America, South America, Asia, and Australia. They saw extensive use in the Northeast United States, both on branch lines and in commuter service. As passenger service declined in the United States the RDC was often the last surviving conveyor of passengers on a particular route. Most RDCs were retired by the 1980s. In Canada, RDCs have remained in continuous use since their introduction in the 1950s.
Recorded from Reading and Northern RDC 9168
This project is a normal idle version. It has single exhaust stacks per motor.
"Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
1st Gen Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie A-125
CV163=1 Leslie A-200
CV163=2 Leslie S-2M
CV163=3 Leslie S-3K
CV163=4 Leslie S-3L
CV163=5 Leslie S-5T
CV163=6 Nathan M3
CV163=7 Nathan M3H
CV163=8 Nathan M5
CV163=9 Nathan P5 (Old Cast)
CV163=10 Nathan P5R24 (Old Cast)
CV163=11 Nathan P3 (Old Cast)
CV163=12 Nathan P3-R4 (Old Cast)
CV163=13 Nathan P5A (Old Cast)
CV163=14 Wabco E-2
CV163=15 Nathan K3HA
CV163=16 Nathan K3L
CV163=17 Nathan K3H
CV163=18 Nathan K5H
EMD 1st Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8004156 Bronze Bell 011
CV164=1 EMD 8475495 Steel Bell 007
CV164=2 EMD 8004156 Bronze Bell 012
CV164=3 EMD 8475495 Steel Bell 009
CV164=4 EMD 8004156 Bronze Bell 013
CV164=5 EMD 8475495 Steel Bell 010
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
1st Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV166=1 Cast Iron Shoe
EMD 1st Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 F7A Air Dryer 1
CV166=1 GP7 Air Dryer 1
CV166=1 GP7U Air Dryer 1
CV166=1 GP7U Air Dryer 2 Hide description more…
If you download the designated file, you agree to be legally bound by the license given above.