")}("width","220px",["/lib/bootstrap-select/css/bootstrap-select.min.css"],"rel=\u0022stylesheet\u0022 ");
The EMD 710 is a line of diesel engines built by Electro-Motive Diesel (EMD). Introduced in 1985, the 710 series replaced the earlier EMD 645 series. Since its introduction, EMD has continually upgraded the 710G diesel engine. Power output has increased from 3,800 horsepower on 1985's 16-710G3A to 4,500 horsepower on 2012's 16-710G3C-T2. Over the production span of certain locomotive models, upgraded engine models have been fitted when these became available. For example, an early 1994-built SD70MAC had a 16-710G3B, whereas a later 2003-built SD70MAC would have a 16-710G3C-T1.
In 2005 EMD was released a Tier 2 710 prime mover for thier upcoming SD70M-2 and SD70ACe models. The SD70M-2 is a DC traction version of the SD70ACe, and the two models are nearly identical in every other respect. Like the SD70ACe, the SD70M-2 models are equipped with the 16-710G3C-T2 prime mover which is rated at 4,300 horsepower. One of the main differences in the SD70M-2/SD70ACes from previous SD70s is the addition of Air Start. This loud burst of air in the start sequence is not present on most earlier EMD locomotives. All SD70M-2s and SD70ACes, except for the ones bought by CITX, are equipped with the Airchime model K5LLA air horn and an electronic bell. Due to this Air Start these locomotives have a period of High Idle just after start up to recharge the air and warm up the locomotive.
Locomotives:
SD70M-2, SD70ACe
Recorded from a EMD SD70ACE
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover to a "Low Idle" and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
SD70ACE/SD70M-2 Horn Pack
Horns (SoundCV9):
CV163=0 Nathan P5
CV163=1 Nathan K5LA
CV163=2 Nathan M3H
CV163=3 Leslie RS-2M
CV163=4 Nathan K3HA
CV163=5 Nathan K3L
CV163=6 Nathan K3H
CV163=7 Nathan K5H
CV163=8 Nathan P5A
CV163=9 Nathan P5 (Old Cast)
CV163=10 Nathan M3RT1
CV163=11 Leslie S3L
CV163=12 Leslie S5T
CV163=13 Nathan K5LR24
CV163=14 Leslie S5TRF
CV163=15 Nathan K5LLA #1
CV163=15 Nathan K5LLA #2
CV163=15 Nathan K5LLA #3
CV163=15 Nathan K5LLA #4
CV163=15 Nathan K5LLA #5
CV163=15 Nathan K5LLA #6 - Default
EMD 3rd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 049
CV164=1 EMD 8475495 Steel Bell 066
CV164=2 EMD 8475495 Steel Bell 068
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
3rd Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4 Hide description more…
The MPXpress line of locomotives were the first production passenger locomotives to meet EPA Tier 1 and Tier 2 emissions regulations, as well as FRA safety regulations regarding crashworthiness and fire safety. Numerous public transit agencies in Canada and the United States have ordered MPXpress locomotives for their commuter rail services. To date only GO Transit and Sounder Commuter Rail in Seattlehave MP40PH-3C in Service.
The prime mover used in the MP40PH-3C is a EMD 16-710GB. The Prototype has a seperate HEP unit for providing Power to the Passengers. This sound is also available in the in this file as a user dependant function that can turned on and off as needed. (Usually if 2 engines are used only the engine closest to the cars will have the HEP unit running)
These Locomotives are used Daily in "Push-Pull" service and are set up to do so as default in this decoder as well. Operating Front and rear red lights and Headlight/Ditchlights are set accordingly as default.
This project is an isolation switch based low idle version. It has a single turbo late (silenced) exhaust stack.
File also contains a "low Idle" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to go to "regular idle" and begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file has a Special feature providing the sounds and operation of the Head End Power unit. This is used on the prototype loco to provide electricity to the coaches as these locos are almost always used in passenger service.
To engage HEP you must be stopped in Idle. Pressing F7 (Shift 2) will engage the HEP unit and allow the prime mover to run at a higher RPM.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
The GO Transit MPI MP40PH-3C were delivered with Nathan K5LA airhorns. In Jan 2008 a Canadian Transport mandate required all passenger
locomotives (or any trains that go above 65mph) use a new horn type and pitches. Nathan Airchime created the K5-CA-LS - THREE CHIME SOFT (NORMAL) AND FIVE CHIME LOUD (EMERGENCY). This is a split manifold horn capable of playing only 3 lower pitched bells in normal use and all 5 for emergencies. These horns intentionally sound "bad" to alert people of the train. We have also included the Kockum Sonics Tyfon MKTH 75-5 Chime CA which sounds VERY MUCH like the emergency horn of the Nathan K5-CA-LS
3rd Gen Horn Pack 1
Horns (SoundCV9):
CV163=0 Nathan K-5LA AMTK ALC-42 Full Air *
CV163=1 Kockum Sonics Tyfon MKTH 75-5 Chime CA *
CV163=2 Nathan K-5LA AMTK ALC-42 Ed2 Full Air *
CV163=3 Kockum Sonics Tyfon MKTH 75-5 Chime CA *
CV163=4 Nathan K-5LA*
CV163=5 Nathan K-5LA-R24*
CV163=6 Nathan K-5L-LA *
CV163=7 Nathan K-5LA Amtrak*
CV163=8 Nathan K5-CA-LS Horn - GO Emergency *
CV163=9 Nathan K5-CA-LS Half Air Horn *
Cv163=10 Nathan K5-CA-LS Half Air Horn Ed2 *
EMD 3rd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 049
CV164=1 EMD 8475495 Steel Bell 066
CV164=2 EMD 8475495 Steel Bell 068
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4 Hide description more…
The EMD 710 is a line of diesel engines built by Electro-Motive Diesel (EMD). Introduced in 1985, the 710 series replaced the earlier EMD 645 series. Since its introduction, EMD has continually upgraded the 710G diesel engine. Power output has increased from 3,800 horsepower on 1985's 16-710G3A to 4,500 horsepower on 2012's 16-710G3C-T2. Over the production span of certain locomotive models, upgraded engine models have been fitted when these became available. For example, an early 1994-built SD70MAC had a 16-710G3B, whereas a later 2003-built SD70MAC would have a 16-710G3C-T1.
Locomotives:
GP60, GP60M, GP60B, SD60, SD60M, SD60I, SD60F, Austrailian National AN Class
Although recorderd from a GP60, this file would be a close match for the following locomotives:
SD50AF, SD70, SD70MAC, SD90MAC, SD50X
Recorded from a EMD GP60
This project has a notch based low idle with automatic high idle. It has a single turbo late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
3rd Generation Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie RS-3L
CV163=1 Leslie RS-5T-RRO
CV163=2 Nathan K-2H
CV163=3 Nathan K-3HL
CV163=4 Nathan K-3L
CV163=5 Nathan K-3LA
CV163=6 Nathan K-5HL-R2
CV163=7 Nathan K-5H-R24
CV163=8 Nathan K-5L
CV163=9 Nathan K-5LA
CV163=10 Nathan K-5LA-R24
CV163=11 Nathan K-5LLA-R1L
CV163=12 Nathan K-5L-R24
CV163=13 Nathan P-3
CV163=14 Nathan P-5-R24
EMD 3rd Generation Bell Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 037
CV164=1 EMD 8475495 Steel Bell 046
CV164=2 EMD 8475495 Steel Bell 056
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1 (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1 (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4
S0531 - Release Notes
===================================================
V-7 R-7:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
V-8 R-8:
===================================================
- Prime mover volume selection mode Hide description more…
The EMD GP59 is a 4-axle diesel road switcher locomotive model built by General Motors Electro-Motive Division between 1985 and 1989. Power was provided by a 12-cylinder EMD 710G3A diesel engine, which could produce 3,000 horsepower (2,200 kW). This locomotive shared the same common frame with the EMD GP60, giving it an overall length of 59 feet 9 inches (18.21 m). It featured a 3,700-US-gallon (14,000 l; 3,100 imp gal) fuel tank. 36 examples of this locomotive were built including three demonstrators. Norfolk Southern placed the only order for the GP59 and also acquired the three demonstrators which featured an aerodynamic cab.
In 2011 Norfolk Southern began a program to upgrade their fleet of GP59s, the only GP59s operating anywhere. The first one was not released until March 2013 as NS 4650 GP59E. The GP59E features a new EM2000 microprocessor, an all-new electrical cabinet with SmartStart auto start/stop, rebuilt 12-710G3C-BC prime-mover with EMDEC EUI system, NS-designed split cooling, the NS Admiral cab with cab signals, LSL, and CCB26 electronic brake valve. The GP59E is set up to operate with NS class RP-M4C road slugs.
While the only Road Switcher in the US to use the 12cyl EMD 710 prime mover, other locomotives did use it around the world.
This 12cyl 710 with Turbo sound file would be appropriate for the following locomotives:
GP59, F59PH - HEP Equipped - Use ESU file Number S0573, F59PHI - HEP Equipped - Use ESU file Number S0573, Australian National DL class, New South Wales 82 Class, SD32ECO, British Rail Class 66 , British Rail Class 67, Irish Rail 201 Class, RENFE Class 334, EMD DE/DM30AC, Euro 3000, WAGR S class (diesel) , Downer EDI Rail GT42CU AC, Downer EDI Rail JT42C-D
Recorded from a EMD GP59
This project is a normal idle version. It has a single turbo late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
3rd Generation Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie RS-3L
CV163=1 Leslie RS-5T-RRO
CV163=2 Nathan K-2H
CV163=3 Nathan K-3HL
CV163=4 Nathan K-3L
CV163=5 Nathan K-3LA
CV163=6 Nathan K-5HL-R2
CV163=7 Nathan K-5H-R24
CV163=8 Nathan K-5L
CV163=9 Nathan K-5LA
CV163=10 Nathan K-5LA-R24
CV163=11 Nathan K-5LLA-R1L
CV163=12 Nathan K-5L-R24
CV163=13 Nathan P-3
CV163=14 Nathan P-5-R24
EMD 3rd Generation Bell Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 037
CV164=1 EMD 8475495 Steel Bell 046
CV164=2 EMD 8475495 Steel Bell 056
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4
S0572 - Release Notes
===================================================
V-8 R-7:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- updated prime mover comment
V-9 R-8:
===================================================
- Prime mover volume selection mode
Hide description more…
The EMD F59PHI is a common diesel-electric locomotive on passenger trains in North America, built originally by General Motors Electro-Motive Division (EMD), now built by the successor company, Electro-Motive Diesel, which is owned by Progress Rail Services, itself a division of Caterpillar.
First built in 1994, the locomotive is a 3,200 hp (2.4 MW) B-B diesel-electric locomotive intended for service on North American mainlines. This locomotive is equipped with a turbocharged EMD 12-710G3C-EC, a 12-cylinder, 2 stroke diesel engine (prime mover). The main (traction) alternator converts mechanical energy from the prime mover into electrical energy that is distributed through a high voltage cabinet to direct current traction motors. Each of the four traction motors is directly geared to a pair of driving wheels. The gear ratio of the traction motors (model D87BTR) to wheel axle determines the maximum operating speed of the locomotive; a standard F59PHI has a gear ratio of 56:21 which provides a top speed of 110 mph (180 km/h).
The F59PHI has a fully enclosed carbody which provides protected walkways for easy access to the engine room and trailing units. This arrangement allows routine maintenance while the locomotive is in service. The noteworthy aspect of this locomotive's exterior is the use of composites to present a streamlined appearance.
To supply electrical power for passenger service, the F59PHI is equipped with a secondary electrical generator referred to as the Head End Power (HEP) unit. The head-end generator generates AC power at 480 V, 60 Hz AC, and can be rated between 500 and 750 kW (670 and 1,010 hp) to provide power to the passenger carriages for lighting, electric heating, and air conditioning. The head-end generator is powered by a second diesel engine dedicated to it. With this arrangement, the prime mover is not burdened by head-end power generation and consequently is used solely for supplying tractive effort.
When it debuted for Caltrans in late 1994, the F59PHI was the first locomotive in the United States which met California's stringent emission standards.
This file has a Special feature providing the sounds and operation of the Head End Power unit. This is used on the prototype loco to provide electricity to the coaches as these locos are almost always used in passenger service.
To engage HEP you must be stopped in Idle. Pressing F26 (Shift 2) will engage the HEP unit and allow the prime mover to run at a higher RPM.
When in stations often the engineer will go into Standby mode to preserve fuel and to allow the noise levels to come down a little. Pressing F27 on the throttle once HEP has already been engaged will allow the prime mover to come down a little. Again this can only be done while sitting still as on the prototype there is not enough RPM to provide power to the coaches and traction motors at the same time in Standy Mode.
This EMD 12-cyl 710G3A-HEP file would be appropriate for the following locomotives:
F59PH, F59PHI, And others...
This project is a normal idle version. It has a single turbo late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file has a Special feature providing the sounds and operation of the Head End Power unit. This is used on the prototype loco to provide electricity to the coaches as these locos are almost always used in passenger service.
To engage HEP you must be stopped in Idle. Pressing F26 (Shift 2) will engage the HEP unit and allow the prime mover to run at a higher RPM.
When in stations often the engineer will go into Standby mode to preserve fuel and to allow the noise levels to come down a little. Pressing F27 on the throttle once HEP has already been engaged will allow the prime mover to come down a little. Again this can only be done while sitting still as on the prototype there is not enough RPM to provide power to the coaches and traction motors at the same time in Standy Mode.
Passenger Horn Pack 1
Horns (SoundCV9):
CV163=0 Nathan K-5LA Ed2
CV163=1 Nathan P-5A-OC
CV163=2 Nathan P01235-OC
CV163=3 Leslie SL-4T
CV163=4 IEC-Holden K-3L
CV163=5 Nathan K-5L
CV163=6 Nathan K-5LA
CV163=7 Nathan P-5A
CV163=8 Nathan P01235
CV163=9 Leslie S-4T
CV163=10 Nathan K-3L
CV163=11 Nathan P-2
CV163=12 Nathan K-3H
CV163=13 Leslie RS-5T-RRO Ed2
CV163=14 Nathan K-5LA (NJT)
CV163=15 Nathan K-5LA (Metra)
EMD 3rd Generation Bell Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 037
CV164=1 EMD 8475495 Steel Bell 046
CV164=2 EMD 8475495 Steel Bell 056
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4
S0573 - Release Notes
===================================================
V-8 R-7:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- updated prime mover comment
- new horn template pack "Passenger Horn Pack 1" Hide description more…
The ALP-45DP is a “dual mode” locomotive, capable of drawing power from either overhead electrical wires or its own pair of 12-cylinder Caterpillar diesel engines. These flexible locomotives were designed to provide a one-seat commute from NJ TRANSIT’s various diesel-only lines into the electrified territory that leads to New York City’s Penn Station. This fulfills the requirement of not operating diesels through the North River Tunnels and within the subterranean Penn Station complex. Produced by Bombardier Transportation in Kassel, Germany, the first ALP-45DP locomotive entered service on NJ TRANSIT on May 30, 2012.
NJ TRANSIT’s 35 ALP-45DP locomotives are commonly seen on commuter trains traversing the Morristown Line, Montclair-Boonton Line, Raritan Valley Line, and North Jersey Coast Line. These lines do not have overhead electrical wires for their entire length, necessitating a change of power source somewhere en-route. Previously, locomotives or entire trainsets would have to be changed, inconveniencing riders. The ALP-45DP alleviates this need, performing the switch from diesel to electric power (or vice versa) in just under two minutes during a routine station stop.
Recorded from a ALP-45DP
This project has a notch based low idle with automatic high idle. It has a single turbo late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
ALP-45DP Horn Pack 1
Horns (SoundCV9):
CV163=0 Nathan K-5H
CV163=1 Nathan K-5HL-R2
CV163=2 Nathan K-5HL-R2 (2nd Gen)
CV163=3 Nathan K-5L
CV163=4 Nathan K-5LA
CV163=5 Nathan K-5LA (NJT)
CV163=6 Nathan K-5LLA-R1L
CV163=7 Nathan K-5LA (AMTK ALC-42)
CV163=8 Nathan K-5LA (AMTK ALC-42) Ed2
CV163=9 Nathan K-5LA (MARC)
CV163=10 Nathan K-5LA (Metra)
ALC-42 Auto Bell On/Off Trigger Template Pack 1
Bells (SoundCV10):
CV164=0 Graham-White E-Bell 010
CV164=1 Graham-White E-Bell 001
CV164=2 Graham-White E-Bell 002
CV164=3 Graham-White E-Bell 003
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1 (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1 (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4
S0595 - Release Notes
===================================================
V-4 R-4:
===================================================
- Prime mover volume selection mode Hide description more…
The SD80MAC is a 5000 horsepower C-C diesel-electric locomotive. The SD80MAC uses a 20 cylinder version of EMD's 710G prime mover,formally known as the V-20 710G3B-ES and is the first diesel locomotive to use a 20-cylinder engine since the SD45/SD45-2. The SD80MAC introduced a wide radiator housing similar to GE locomotives and the placement of dynamic brakes at the rear of the locomotive. Key spotting difference between the SD80MAC and SD90MAC include: no external rear sandbox on the 90MAC, rear number boards, and the placement of the front numberboards (above the cab windows on the SD80MAC, on the nose on most SD90MACs). The SD80MAC also has recessed red marker lights in the nose, an identifying feature unique to Conrail locomotives, although NS has removed the lights on most of their former Conrail engines.
We've tried to be as prototypical as possible with this iconic locomotive. Because of this, the notching on this SD80MAC file may be slightly different from what you are used to. Like many modern EMDs there is a warm-up cycle when you initially turn on the prime mover. This will cause the prime mover to rise and hold for a short period of time. There is also a high and low idle dictated by the isolation switch. If the isolation switch is not activated Notch 1 and Notch 2 are the same as this is high idle. Activating the islolation switch will drop the sounds to low idle.
Recorded from a EMD SD80MAC
This project is an isolation switch based low idle version. It has a single turbo late (silenced) exhaust stack.
File also contains a "low Idle" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to go to "regular idle" and begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
3rd Generation Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie RS-3L
CV163=1 Leslie RS-5T-RRO
CV163=2 Nathan K-2H
CV163=3 Nathan K-3HL
CV163=4 Nathan K-3L
CV163=5 Nathan K-3LA
CV163=6 Nathan K-5HL-R2
CV163=7 Nathan K-5H-R24
CV163=8 Nathan K-5L
CV163=9 Nathan K-5LA
CV163=10 Nathan K-5LA-R24
CV163=11 Nathan K-5LLA-R1L
CV163=12 Nathan K-5L-R24
CV163=13 Nathan P-3
CV163=14 Nathan P-5-R24
EMD 3rd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 049
CV164=1 EMD 8475495 Steel Bell 066
CV164=2 EMD 8475495 Steel Bell 068
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4
S0596 - Release Notes
===================================================
V-4 R-4:
===================================================
- remastered prime mover
- new prime mover volume mode
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- updated prime mover comment Hide description more…
The EMD 710 is a line of diesel engines built by Electro-Motive Diesel (EMD). Introduced in 1985, the 710 series replaced the earlier EMD 645 series. Since its introduction, EMD has continually upgraded the 710G diesel engine. Power output has increased from 3,800 horsepower on 1985's 16-710G3A to 4,500 horsepower on 2012's 16-710G3C-T2. Over the production span of certain locomotive models, upgraded engine models have been fitted when these became available. For example, an early 1994-built SD70MAC had a 16-710G3B, whereas a later 2003-built SD70MAC would have a 16-710G3C-T1.
This prime mover was recorded from an SD70MAC with a 16cyl 710G3B.
This would be correct for the following locomotives:
SD70, SD70M, SD70MAC, SD70I, SD60E (upgraded to 710G3B from 710G3A)
Though recorded from an SD70MAC it would be very close to the following locomotives:
SD50AF, GP60, GP60M, GP60B, SD60, SD60M, SD60I, SD60F, SD75M, SD75I, Austrailian National AN Class, SD90/43MAC, SD50X, GT46C, and others...
Recorded from a EMD SD70MAC
This project is an isolation switch based low idle version. It has a single turbo late (silenced) exhaust stack.
File also contains a "low Idle" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to go to "regular idle" and begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
3rd Gen Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie S-3L-R
CV163=1 Leslie S-5T-RRO-R
CV163=2 Nathan K-2H
CV163=3 Nathan K-3H-L
CV163=4 Nathan K-3L
CV163=5 Nathan K-3LA
CV163=6 Nathan K-5HL
CV163=7 Nathan K-5H-R24
CV163=8 Nathan K-5L
CV163=9 Nathan K-5LA
CV163=10 Nathan K-5LA-R24
CV163=11 Nathan K-5L-LA
CV163=12 Nathan K-5L-R24
CV163=13 Nathan P-3
CV163=14 Nathan P-5-R24
EMD 3rd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 049
CV164=1 EMD 8475495 Steel Bell 066
CV164=2 EMD 8475495 Steel Bell 068
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4 Hide description more…
The SD60E program was designed to upgrade 1980's SD60s with current electronic controls and crash-worthiness upgrades in Norfolk Southern's Juniata shops in Altoona PA.
The rebuilds receive a Tier 0+ 16-710G3B prime mover rated at 4,000 hp, compared to the standard SD60's 3,800 hp. Along with the HP upgrade they also received all new wiring and EMD's EM2000 microprocessor controls. These new controls altered the notching slightly in these rebuilt locomotives.
This ESU Sound file will operate like the prototype in terms of throttle notching. You will notice there is low and high idle, and once above notch 3 and back to Idle the prime mover will stay up in high idle for a period of time. Once in low idle throttling up to notch 1 or notch 2 and return to idle will stay in low idle.
Recorded from a EMD SD60E
This project is a special notch based low idle with an automatic high idle version. It has a single turbo late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover to a "Low Idle" and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cycle
CV168=3 - 9 Minute Cycle
CV168=4 - 12 Minute Cycle
Etc.....
CV168=255 - 765 Minute Cycle
3rd Generation Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie RS-3L
CV163=1 Leslie RS-5T-RRO
CV163=2 Nathan K-2H
CV163=3 Nathan K-3HL
CV163=4 Nathan K-3L
CV163=5 Nathan K-3LA
CV163=6 Nathan K-5HL-R2
CV163=7 Nathan K-5H-R24
CV163=8 Nathan K-5L
CV163=9 Nathan K-5LA
CV163=10 Nathan K-5LA-R24
CV163=11 Nathan K-5LLA-R1L
CV163=12 Nathan K-5L-R24
CV163=13 Nathan P-3
CV163=14 Nathan P-5-R24
EMD 3rd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 049
CV164=1 EMD 8475495 Steel Bell 066
CV164=2 EMD 8475495 Steel Bell 068
CV164=3 Graham-White E-Bell 006 - Default
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4
S0757 - Release Notes
===================================================
V-5 R-5:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- updated prime mover comment Hide description more…
EMD SD90MAC-H Phase II or SD70ACe-T4?
The SD70ACe-T4 is the Tier 4 emissions standards-compliant version of the SD70ACe. The first locomotive, EMDX 1501, was built in summer 2015, and made its debut at the Railway Interchange Expo in Minneapolis, Minnesota during the weekend of October 3–4, 2015. It features a new 4-stroke engine called the EMD 12-1010 "J" series - a V12 with 1010 cu.in displacement for each cylinder. This new prime mover has a two-stage turbocharger system consisting of three turbos; one turbo (the primary/high pressure turbo) for low-mid RPM and two turbos (the secondary/low pressure turbos) for mid-high RPM. The results of this setup are higher power throughout a broader RPM range, better fuel efficiency, and lower emissions. An EGR system is applied as well, allowing the engine to achieve Tier 4 without the use of urea aftertreatment. Another new feature of this engine is the Double-Walled Fuel Injection System that increases safety and provides simplified maintenance works.
The EMD 12-1010 is capable of producing 4,600 hp, but only 4,400 tractive horsepower.[15] With a new computer software for the on-board computer and one inverter per axle (or "P6"; EMD named it "Individual Axle Control") - unlike most of previous EMD locomotives that use one inverter per truck, the SD70ACe-T4 is capable of generating 200,000 lbf. (889.64 kN.) of starting tractive effort, and 175,000 lbf. (778.75 kN.) of continuous tractive effort. Meanwhile, its dynamic braking effort is as much as 105,000 lbf. (467.25 kN.) The amount of starting tractive effort is equal to that of the 6,000 hp SD90MAC-H while, on the other hand, its continuous tractive effort is higher than that of the SD90MAC-H (175,000 lbf. vs. 165,000 lbf.). The units are also equipped with "radial bogies" which offer increased adhesion and better ride quality.
While it retains the basic SD70 designation, the locomotive has several major new features that set it apart from its successful ancestor such as a vibration-isolated powertrain, and alternator start capability. In addition, it features a newly redesigned cab reminiscent of the earlier SD70M, featuring the classic "teardrop" windshields first introduced on the FP45 in December 1967; new fabricated trucks; a longer frame (76 ft. 8 in / 23.37 m); longer radiators with three radiator fans instead of two; an additional step on the front and rear; and a smoother long hood roofline.
Fifteen SD70ACe-T4 demonstrators were built at Muncie, IN by November 2016. Union Pacific Railroad is the first customer to order SD70ACe-T4's. UP 3012-3014, the first production SD70ACe-T4's, were assigned to active service in early November 2016.
Union Pacific will acquire 100 SD70ACe-T4's: 12 former demonstrators will be rostered as UP 3000-3011, and 88 production units (3012-3099). 3012-3056 were built at Bombardier's Sahagun, Mexico plant. 3057-3099 will be built at Muncie, IN, following completion of the Tier 4 credit SD70ACe's UP 8997-9096. All UP SD70ACe-T4's are classified as SD70AHs.
EMDX 1501 will remain in Progress Rail Services ownership as a test bed.
SD70ACeP4-T4's EMDX 1603 and 1604 were built and painted as demonstrators for the BNSF Railway. These units have a B1-1B wheel arrangement akin to the SD70ACe-P4.
In August 2018, CSX Transportation ordered 10 SD70ACe-T4's, of which all have now been delivered. They are classified by CSX as ST70AH.
Norfolk Southern initially also ordered 10 SD70ACe-T4's, but later cancelled the order, instead opting for more SD70ACe Tier-4 credit locomotives.
Text is available under the Creative Commons Attribution-ShareAlike License
Locomotives:
EMD SD70ACE T4
SD70ACeP4-T4
EMD ST70AH
SD90MAC-H Phase II
While not exactly the same, The EMD 12-1010J prime mover sounds very much like the EMD GM16V265H used in the SD90MAC-H Phase II locomotives. While the prime mover has been discontinued and mostly scrapped in the US there are a few operating examples in China and Australia. Hopefully someday a true recording can be acquired but for now this is quite close!
As no models have been created for the SD70ACe T4 at the time of this file release we have set up the function mapping and horn and bell sounds to work with the Athearn SD90MAC-H Phase II locomotives.
Recorded from an EMD SD70ACE T4
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover to a "Low Idle" and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
SD70ACE/SD70M-2 Horn Pack
Horns (SoundCV9):
CV163=0 Nathan P5
CV163=1 Nathan K5LA
CV163=2 Nathan M3H
CV163=3 Leslie RS-2M
CV163=4 Nathan K3HA - Default
CV163=5 Nathan K3L
CV163=6 Nathan K3H
CV163=7 Nathan K5H
CV163=8 Nathan P5A
CV163=9 Nathan P5 (Old Cast)
CV163=10 Nathan M3RT1
CV163=11 Leslie S3L
CV163=12 Leslie S5T
CV163=13 Nathan K5LR24
CV163=14 Leslie S5TRF
CV163=15 Nathan K5LLA #1
CV163=15 Nathan K5LLA #2
CV163=15 Nathan K5LLA #3
CV163=15 Nathan K5LLA #4
CV163=15 Nathan K5LLA #5
CV163=15 Nathan K5LLA #6
EMD 3rd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 049
CV164=1 EMD 8475495 Steel Bell 066
CV164=2 EMD 8475495 Steel Bell 068
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
3rd Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4 Hide description more…
If you download the designated file, you agree to be legally bound by the license given above.