The ALCO 251 prime mover was the most popular and abundant prime mover ever made by the company. While it proved to be quite successful, it sadly outlived its original manufacturer, ALCO who closed their doors in 1969. The 251 prime mover is actually still available to purchase today from Fairbanks Morse for use in Marine, Generator, and locomotive uses.
The 12cyl 251C can be found in the following Locomotives:
RS-32, C420, M420, M420B, M420R, M420TR, HR-412, M424, 45 Class, 442 Class, 600 Class, 700 Class, A-321
The 2000 Horsepower 12cyl 251C version was extremely close to 251B in the way that is sounded. The 1800 horsepower 12cyl version of the 251B could be found in the following locomotives:
RS-11, RSD-12, RS-18, RS-36, FPA-4, FPB-4, RSC-14, FD-6, FD-7, FD-9, RSD-16, DL-560, 44 Class, 930 Class
The 12cyl 251 was also used in many rebuilt locomotives including:
RS-3m, C424m, and others...
Recorded from a ALCO C-420
This project is a normal idle version. It has a single exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
1st Generation Horn Pack 2
Horns (SoundCV9):
CV163=0 Leslie S-3E
CV163=1 Leslie S-3K-R
CV163=2 Leslie S-3L-R
CV163=3 Leslie S-5T-F
CV163=4 Leslie S-5T-R
CV163=5 Leslie S-5T-RRO
CV163=6 Leslie SL-4T
CV163=7 Nathan K-5LA
CV163=8 Nathan M-3-HR2 (Temp Nathan M-3-H)
CV163=9 Nathan M-3-R1
CV163=10 Nathan M3RT1
CV163=11 Nathan M-5-R24 (Temp Nathan M-5)
CV163=12 Wabco A2
ALCO Bell Template Pack 1
Bells (SoundCV10):
CV164=0 ALCO Bronze Bell 003
CV164=1 ALCO Bronze Bell 005
CV164=2 ALCO Bronze Bell 006
CV164=3 ALCO Bronze Bell 010
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
1st Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Cast Iron Shoe #1
ALCO Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 S-1 Air Dryer 1
CV166=1 C-425 Air Dryer 1
CV166=2 RS-18 Air Dryer 1
CV166=3 RS-18 Air Dryer 2 Hide description more…
The GE B23-7 diesel locomotive was first offered in late 1977. Featuring a smaller 12 cylinder version of the FDL engine, it is the successor to GE's U23B produced from early 1968 to mid 1977, but at 62 ' 2" long, the B23-7 is exactly 2' 0" longer than the firms U23B. The B23-7 competed with the very successful EMD GP38-2. General Electric also produced a variant, the BQ23-7, for the Seaboard Coast Line. A total of 537 B23-7's were built for 9 U.S. customers and 2 Mexican customers.
This sound file is appropriate for the following locomotives:
B23-7, BQ23-7, B30-7A, C30-7A
Unlike our 75405 Early 12cyl 7FDL which is correct for The "U-Series" locomotives, this 12cyl 7FDL is more appropriate for the "Dash-7 Series" of GE locomotives.
While this prime mover is not completely accurate for the following locomotives it would also be an suitable alternative to break up the monotony on your railroad.
U18D, U20C, U23B, U23C, U26C, Dash 8-32B (B32-8), Dash 8-32C (C32-8)
Recorded from a GE B23-7
This project is a normal idle version. It has a single late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
2nd Gen Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie S-3K-R
CV163=1 Leslie S-3L-R
CV163=2 Leslie S-5T-F
CV163=3 Leslie S-5T-R
CV163=4 Nathan K-3H
CV163=5 Nathan K-3L
CV163=6 Nathan K-3LA
CV163=7 Nathan K-5H
CV163=8 Nathan K-5LA
CV163=9 Nathan K-5LA-R24
CV163=10 Nathan M-3
CV163=11 Nathan M-3H
CV163=12 Nathan P-3
CV163=13 Nathan P-5-R24
GE Dash 7 Bell Template Pack 2
Bells (SoundCV10):
CV164=0 GE M 6731022A Steel Bell 011
CV164=1 GE M 6731022A Steel Bell 014
CV164=2 GE M 6731022A Steel Bell 023
CV164=3 GE M 6731022A Steel Bell 024
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV166=1 Cast Iron Shoe
GE Dash 7 Air Dryer Template Pack 2
Air Dryer (SoundCV12)
CV166=0 B23-7 Air Dryer 1
CV166=1 B23-7 Air Dryer 2
CV166=2 B23-7 Air Dryer 3
CV166=3 B23-7 Air Dryer 4 Hide description more…
The EMD 645 series was an evolution of the earlier 567 series and a precursor to the later 710 series. When the 645 prime mover entered production in 1965, a large series of new locomotive models was introduced. The turbocharged version was used in EMD's 40 Series (GP40, SD40 and SD45) in 3,000 horsepower (2,200 kW), sixteen-cylinder form and in 3,600 horsepower (2,700 kW), twenty-cylinder form. EMD also introduced the Roots-blown 38 Series (GP38, SD38) and turbocharged, twelve-cylinder 39 Series (GP39, SD39). All of these locomotive models extensively share common components and subsystems, thereby significantly reducing cost and increasing interchangeability. The GP38-2 and SD40-2 became the most popular models of the series and among the most popular locomotive models ever built.
This 16cyl 645E3 with Turbo sound file would be appropriate for the following locomotives:
GP40, GP40P, GP40P-2, GP40-2, GP40X, SD40X, SD40A, SD45T-2, SD40-2, SD40-2W, SD40-2S, F40C, F40PH, F40PH-2, F40PH-2M, SDP40F, SD40-2F
Export locomotives:
GT26MC, GT26CW, GT26CW-1, GT26CW-2, GT26CU-2
Recorded from a GMD SD40-2
This project is a normal idle version. It has a single turbo early exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
2nd Generation Horn Pack 4
Horns (SoundCV9):
CV163=0 Leslie S-3K-R
CV163=1 Leslie S-3L-R
CV163=2 Leslie S-5T-RRO-R
CV163=3 Nathan K-3L
CV163=4 Nathan K-3L-R2 (temp K-3L)
CV163=5 Nathan K-5H-R24
CV163=6 Nathan K-5L
CV163=7 Nathan K-5L-R24
CV163=8 Nathan M-3H
CV163=9 Nathan M-3H-R2 (temp M-3H)
CV163=10 Nathan M-3-RT1
CV163=11 Nathan M-5
CV163=12 Nathan P-3-R2 (temp P-3)
CV163=13 Nathan P-5-R24
CV163=14 Prime PM-990
GMD 2nd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8004156 Bronze Bell 018
CV164=1 EMD 8004156 Bronze Bell 019
CV164=2 EMD 8475495 Steel Bell 020
CV164=3 EMD 8475495 Steel Bell 021
CV164=4 EMD 8475495 Steel Bell 023
CV164=5 EMD 8475495 Steel Bell 069
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV166=1 Cast Iron Shoe
EMD 2nd Generation Air Dryer Template Pack 2
Air Dryer (SoundCV12)
CV166=0 SD40-2 Air Dryer 5
CV166=1 SD40-2 Air Dryer 6
CV166=2 SD40-2 Air Dryer 7
CV166=3 SD40-2 Air Dryer 8 Hide description more…
The EMD 645 series was an evolution of the earlier 567 series and a precursor to the later 710 series. When the 645 prime mover entered production in 1965, a large series of new locomotive models was introduced. The turbocharged version was used in EMD's 40 Series (GP40, SD40 and SD45) in 3,000 horsepower (2,200 kW), sixteen-cylinder form and in 3,600 horsepower (2,700 kW), twenty-cylinder form. EMD also introduced the Roots-blown 38 Series (GP38, SD38) and turbocharged, twelve-cylinder 39 Series (GP39, SD39). All of these locomotive models extensively share common components and subsystems, thereby significantly reducing cost and increasing interchangeability. The GP38-2 and SD40-2 became the most popular models of the series and among the most popular locomotive models ever built.
This 16cyl 645E3 with Turbo sound file would be appropriate for the following locomotives:
GP40, GP40P, GP40P-2, GP40-2, GP40X, SD40X, SD40A, SD45T-2, SD40-2, SD40-2W, SD40-2S, F40C, F40PH, F40PH-2, F40PH-2M, SDP40F, SD40-2F
Export locomotives:
GT26MC, GT26CW, GT26CW-1, GT26CW-2, GT26CU-2
Recorded from a GMD SD40-2W
This project is a normal idle version. It has a single turbo early exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
2nd Generation Horn Pack 4
Horns (SoundCV9):
CV163=0 Leslie RS-3L
CV163=1 Leslie RS-5T-RRO
CV163=2 Leslie S-3K-R
CV163=3 Nathan K-3L
CV163=4 Nathan K-3L-R2
CV163=5 Nathan K-5H-R24
CV163=6 Nathan K-5L
CV163=7 Nathan K-5L-R24
CV163=8 Nathan M-3H
CV163=9 Nathan M-3H-R2
CV163=10 Nathan M-3-RT1
CV163=11 Nathan M-5
CV163=12 Nathan P-3-R2
CV163=13 Nathan P-5-R24
CV163=14 Prime PM-990
GMD 2nd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8004156 Bronze Bell 018
CV164=1 EMD 8004156 Bronze Bell 019
CV164=2 EMD 8475495 Steel Bell 020
CV164=3 EMD 8475495 Steel Bell 021
CV164=4 EMD 8475495 Steel Bell 023
CV164=5 EMD 8475495 Steel Bell 069
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV165=1 Cast Iron Shoe
EMD 2nd Generation Air Dryer Template Pack 2
Air Dryer (SoundCV12)
CV166=0 SD40-2 Air Dryer 5
CV166=1 SD40-2 Air Dryer 6
CV166=2 SD40-2 Air Dryer 7
CV166=3 SD40-2 Air Dryer 8
S0732 - Release Notes
===================================================
V-3 R-3:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- updated prime mover comment Hide description more…
The EMD 645 family of diesel engines were designed and manufactured by the Electro-Motive Division of General Motors. The 645 series was an evolution of the earlier 567 series and a precursor to the later 710 series. The 645 series engines entered production in 1965. All 645 engines utilize forced induction, with either a Roots blower or a turbocharger. The 645 series has a maximum engine speed of between 900 and 950 revolutions per minute (rpm), an increase over the 800 to 900 rpm maximum speed for the 567 series.
Our 12cyl 645E variation is appropriate for the following locomotives:
GP15-1, GP15AC, SW-1500, SW-1504, MP15AC, MP15DC
Recorded from a EMD SW1500
This project is a normal idle version. It has switcher type exhaust with 2 exhaust stacks.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
2nd Generation Switcher Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie A-125
CV163=1 Leslie S-25
CV163=2 Leslie S-3K-R
CV163=3 Leslie S-3L-R
CV163=4 Leslie S-5T-R
CV163=5 Nathan K-3L
CV163=6 Nathan K-3LA
CV163=7 Nathan K-5LA
CV163=8 Nathan M-3H
CV163=9 Nathan P-3
CV163=10 Nathan P-5
CV163=11 Prime PM-920
CV163=12 Prime PM-990
EMD 2nd Generation Switcher Bell Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 008
CV164=1 EMD 8004156 Bronze Bell 006
CV164=2 EMD 8004156 Bronze Bell 033
CV164=3 EMD 8004156 Bronze Bell 036
CV164=4 Graham-White E-Bell 007
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
Switcher Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV166=1 Cast Iron Shoe
EMD 2nd Generation Switcher Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 SW1500 Air Dryer 1
CV166=1 SW1500 Air Dryer 2
CV166=2 SW1500 Air Dryer 3
CV166=3 MP15DC Air Dryer 4 Hide description more…
In October 1956 the NSWGR took delivery of 4301, the first unit of an order for six locomotives to be built by A Goninan and Co at their Broadmeadow plant in suburban Newcastle. In June 1957 the last of the class, 4306, entered service. They were fitted with an Alco 244 engine and were rated at 1600hp (1193kW) for traction.
While recorded from a 43 Class this 12cyl 244 prime mover sound file would also work in the following locomotives.
RS-2, RSC-2, RS-3, RSC-3, RS-10, RSC-2, RSC-3, RSD-4, RSD-5, MRS-1, RSC-24, FCA-3, DL-500, And others!
Although there are slight differences, this sound file could also be used in the following locomotives:
FA-1, FB-1, FA-2, FB-2, FPA-2, FPB-2
As there are no 16cyl 244 equipped locos remaining, the 12cyl 244 would be a close stand in for the following Locomotives:
PA-1, PB-1, PA-2, PB-2, RSD-7
Recorded from 4306 at the Rail Transport Museum at Thirlmere.
This project is a normal idle version. It has a single exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Australia Horn Pack 1
Horns (SoundCV9):
CV163=0 Australian Leslie S-2M (Leslie S-2M)
CV163=1 Australian Leslie S-3K-R (Leslie S-3K-R)
CV163=2 Australian Nathan K5H (Nathan K-5H)
CV163=3 Australian Nathan M3 (Nathan M-3)
CV163=4 Australian Nathan M3H (Nathan M-3H)
CV163=5 Australian Nathan M5 (Nathan M-5)
CV163=6 Australian Nathan P5( Nathan P5)
CV163=7 Australian Nathan P5 (Old Cast) (Nathan P-5-OC)
CV163=8 Directional RVB Hurricane 5-Chime (RVB Hurricane 5-Chime)
CV163=9 RVB Hurricane 3 Chime (RVB Hurricane 5-Chime)
CV163=10 RVB Hurricane 5-Chime
CV163=11 RVB Hurricane 5-Chime V2 (RVB Hurricane 5-Chime)
CV163=12 Twin RVB Hurricane 5-Chime (RVB Hurricane 5-Chime)
CV163=13 Wabco AABB #1
CV163=14 Wabco AABB #2
CV163=15 Westinghouse Single A-B (Wabco AABB #2)
CV163=16 Kockum Sonics 5 Chime
CV163=17 Nathan Airchime K2
CV163=18 Nathan K5UL-AU-LS
Australia Bell Template Pack 1
Bells (SoundCV10):
CV164=0 ALCO Bronze Bell 010
CV164=1 GE M 6731022A Steel Bell 001
CV164=2 EMD 8004156 Bronze Bell 001
CV164=3 EMD 8004156 Bronze Bell 009
CV164=4 EMD 8475495 Steel Bell 002
CV164=4 EMD 8475495 Steel Bell 010
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
1st Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Cast Iron Shoe #1
ALCO Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 S-1 Air Dryer 1
CV166=1 C-425 Air Dryer 1
CV166=2 RS-18 Air Dryer 1
CV166=3 RS-18 Air Dryer 2 Hide description more…
As the EMD 567s got worn, Many Railroads underwent rebuild programs to prolong the life of their locomotives. One Program in particular was the Uceta GP-16 program on the SCL. Starting in 1979 they took many of their GP7s, GP9s, and GP18s and replaced the existing 567 prime movers with 16cyl 645C Power Assemblies. This combination resulted in a unique sound never before released in the Model Railroad Market.
There were a number of these rebuild programs by many railroads. CN Had GP9RMs, The DM&IR had SD-Ms rebuilt from SD9's and SD18's and others.
16cyl 567s were not the only ones to be rebuilt many 12cyls also recieved this upgrade. This file represents a 12cyl upgrade to 645 Assemblies.
While there were different Exhuast configurations, This file will be very close to the following locomotives:
Rebuilt SW-1200RS
Rebuilt GMD-1
Rebuilt SW1200
and others
Recorded from a GMD-1
This project is a normal idle version. It has switcher type exhaust with 2 exhaust stacks.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
1st Generation Switcher Horn Pack 1
Horns (SoundCV9):
CV163=0 Handcock 4700 Whistle
CV163=1 Leslie A-125
CV163=2 Leslie A-200
CV163=3 Leslie S-25
CV163=4 Leslie S-2M
CV163=5 Leslie S-3K
CV163=6 Leslie S-3L
CV163=7 Nathan M-3
CV163=8 Nathan M-5
CV163=9 Nathan P-2
CV163=10 Nathan P-3-OC
CV163=11 Nathan P-5-OC
CV163=12 Wabco A-2
CV163=13 Wabco AA-2
CV163=14 Wabco E-2
CV163=15 Nathan K-3L
GMD Auto Bell On/Off Trigger Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8004156 Bronze Bell 009
CV164=1 EMD 8475495 Steel Bell 001
CV164=2 EMD 8004156 Bronze Bell 023
CV164=3 EMD 8475495 Steel Bell 002
CV164=4 Transtronic E-Bell 001
CV164=5 Graham-White E-Bell 004
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
Switcher Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Cast Iron Shoe #1
EMD 1st Generation Switcher Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 NW2 Air Dryer 1
CV166=1 NW5 Air Dryer 1
CV166=2 SW7 Air Dryer 1
CV166=3 SW10 Air Dryer 1
S0741 - Release Notes
===================================================
V-2 R-2:
===================================================
- remastered prime mover
- new air compressor
- new prime mover volume mode Hide description more…
The Uceta GP16s were the result of a Seaboard Coast Line rebuild program upgrading GP7, GP9 and GP18 EMD locomotives. Unlike the GP10 program which retained a 567 16cyl prime mover, GP16s recieved 645 power assemblies. A 4 stack exhaust was also applied in most cases. Most ex GP7's had a 16-645BC prime mover. While ex GP9's in many cases had a 16-645C. In some rare cases some GP16's had a new 16-645E prime mover. US Army GP16's had brand new 645E's in them. Check your prototype. Today, many smaller railroads still use GP16s and it was deemed a rather successful program.
Recorded from a EMD GP16
This project is a normal idle version. It has 4 exhaust stacks.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
1st Generation Horn Pack 3
Horns (SoundCV9):
CV163=0 Leslie S-3K-R
CV163=1 Leslie S-3L-R
CV163=2 Leslie S-5T-RRO-R
CV163=3 Leslie SU-3L-R (Temp Leslie S-3L-R)
CV163=4 Nathan K-3H
CV163=5 Nathan K-3L
CV163=6 Nathan K-3LA
CV163=7 Nathan K-5H
CV163=8 Nathan K-5LA-R23
CV163=9 Nathan K-5LA-R24
CV163=10 Nathan P-2 (Temp Nathan P-3)
CV163=11 Nathan P-3
CV163=12 Nathan P-5
CV163=13 Nathan P-5A
CV163=14 Nathan P-5-R24
EMD 1st Generation Bell Template Pack 3
Bells (SoundCV10):
CV164=0 EMD 8004156 Bronze Bell 014
CV164=1 EMD 8475495 Steel Bell 013
CV164=2 EMD 8004156 Bronze Bell 015
CV164=3 EMD 8475495 Steel Bell 024
CV164=4 EMD 8004156 Steel Bell 028
CV164=5 Graham-White E-Bell 005
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
1st Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV166=1 Cast Iron Shoe
EMD 1st Generation Air Dryer Template Pack 7
Air Dryer (SoundCV12)
CV166=0 GP16 Air Dryer 1
CV166=1 GP16 Air Dryer 2
CV166=1 GP16 Air Dryer 3
CV166=1 GP16 Air Dryer 4 Hide description more…
The American Locomotive Company's model 244 prime mover was developed during the mid-1940s to power its post-war diesel locomotives. Interestingly, while Alco helped pioneer diesel technology dating back to the 1920s it had difficulty truly competing against Electro-Motive-Division due to reliability issues with its diesel engines. Before Alco began implementing the 244 in its locomotives the builder had spent most of the 1930s developing an earlier model that was used in most of its early switchers. The new prime mover was supposed to usher in a new era for Alco but instead saw it slip further behind EMD in the marketplace. During the early 1950s the manufacturer replaced the engine with the more reliable 251 that powered its Century series. It would prove to be the company's last engine as it exited the market before 1970.
This sound file would be appropriate for the following locomotives:
RS-2, RS-3, RSC-2, RSC-3, RSD-4, RSD-5
Although there are slight differences, this sound file could also be used in the following locomotives:
FA-1, FB-1, FA-2, FB-2, FPA-2, FPB-2
Recorded from a ALCO RS-3
This project is a normal idle version. It has a single exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
1st Generation Switcher Horn Pack 1
Horns (SoundCV9):
CV163=0 Handcock 4700 Whistle (Temp No Loop)
CV163=1 Leslie A-125
CV163=2 Leslie A-200
CV163=3 Leslie S-25 (Temp Leslie S-2M)
CV163=4 Leslie S-2M
CV163=5 Leslie S-3K
CV163=6 Leslie S-3L
CV163=7 Nathan M-3
CV163=8 Nathan M-5
CV163=9 Nathan P-2 (Temp Nathan P-3-OC)
CV163=10 Nathan P-3-OC
CV163=11 Nathan P-5-OC
CV163=12 Wabco A2
CV163=13 Wabco AA-2 (Temp Wabco A2)
CV163=14 Wabco E-2
ALCO Bell Template Pack 3
Bells (SoundCV10):
CV164=0 ALCO Bronze Bell 004
CV164=1 ALCO Bronze Bell 007
CV164=2 ALCO Bronze Bell 009
CV164=3 ALCO Bronze Bell 012
CV164=4 ALCO Bronze Bell 013
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
Switcher Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Cast Iron Shoe #1
ALCO Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 S-1 Air Dryer 1
CV166=1 C-425 Air Dryer 1
CV166=2 RS-18 Air Dryer 1
CV166=3 RS-18 Air Dryer 2 Hide description more…
The ALCO 251 prime mover was the most popular and abundant prime mover ever made by the company. While it proved to be quite successful, it sadly outlived its original manufacturer, ALCO who closed their doors in 1969. The 251 prime mover is actually still available to purchase today from Fairbanks Morse for use in Marine, Generator, and locomotive uses.
The 12cyl 251C can be found in the following Locomotives:
RS-32, C420, M420, M420B, M420R, M420TR, HR-412, M424, 45 Class, 442 Class, 600 Class, 700 Class, A-321
The 2000 Horsepower 12cyl 251C version was extremely close to 251B in the way that is sounded. The 1800 horsepower 12cyl version of the 251B could be found in the following locomotives:
RS-11, RSD-12, RS-18, RS-36, FPA-4, FPB-4, RSC-14, FD-6, FD-7, FD-9, RSD-16, DL-560, 44 Class, 930 Class
The 12cyl 251 was also used in many rebuilt locomotives including:
RS-3m, C424m, and others...
Recorded from a ALCO C-420
This project is a normal idle version. It has a single exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
1st Generation Horn Pack 2
Horns (SoundCV9):
CV163=0 Leslie S-3J
CV163=1 Leslie S-3K-R
CV163=2 Leslie RS-3L
CV163=3 Leslie S-5T-F
CV163=4 Leslie S-5T-R
CV163=5 Leslie S-5T-RRO
CV163=6 Leslie SL-4T
CV163=7 Nathan K-5LA
CV163=8 Nathan M-3H-R2
CV163=9 Nathan M-3-R1
CV163=10 Nathan M-3-RT1
CV163=11 Nathan M-5-R24
CV163=12 Wabco A-2
ALCO Bell Template Pack 1
Bells (SoundCV10):
CV164=0 ALCO Bronze Bell 003
CV164=1 ALCO Bronze Bell 005
CV164=2 ALCO Bronze Bell 006
CV164=3 ALCO Bronze Bell 010
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
1st Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Cast Iron Shoe #1
ALCO Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 S-1 Air Dryer 1
CV166=1 C-425 Air Dryer 1
CV166=2 RS-18 Air Dryer 1
CV166=3 RS-18 Air Dryer 2
S0745 - Release Notes
===================================================
V-4 R-4:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- updated prime mover comment section Hide description more…
If you download the designated file, you agree to be legally bound by the license given above.