The EMD 645 family of diesel engines were designed and manufactured by the Electro-Motive Division of General Motors. The 645 series was an evolution of the earlier 567 series and a precursor to the later 710 series. The 645 series engines entered production in 1965. All 645 engines utilize forced induction, with either a Roots blower or a turbocharger. The 645 series has a maximum engine speed of between 900 and 950 revolutions per minute (rpm), an increase over the 800 to 900 rpm maximum speed for the 567 series.
Our 8cyl 645E variation is appropriate for the following locomotives:
SW1000, SW1001, G18, GA18, GL18M, GL18B, G18AR, GT22C-3M, G22, GL22C-2, JL18, 1550 Class, 1502 CLass, 2400 Class, and others...
Recorded from a EMD SW1000
This project is a normal idle version. It has switcher type exhaust with a single exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
2nd Generation Switcher Horn Pack 2
Horns (SoundCV9):
CV163=0 Leslie S-25
CV163=1 Leslie S-31
CV163=2 Leslie S-2M Ed2
CV163=3 Leslie S-3K
CV163=4 Leslie S-3L
CV163=5 Leslie RS-25
CV163=6 Leslie RS-31
CV163=7 Leslie RS-3L
CV163=8 Nathan P-3
CV163=9 Nathan P-5 Ed2
CV163=10 Nathan K-3HA
CV163=11 Nathan K-3LA
CV163=12 Nathan M-3 Ed2
EMD 2nd Generation Switcher Bell Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 008
CV164=1 EMD 8004156 Bronze Bell 006
CV164=2 EMD 8004156 Bronze Bell 033
CV164=3 EMD 8004156 Bronze Bell 036
CV164=4 Graham-White E-Bell 007
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
Switcher Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV165=1 Cast Iron Shoe
EMD 2nd Generation Switcher Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 SW1500 Air Dryer 1
CV166=1 SW1500 Air Dryer 2
CV166=2 SW1500 Air Dryer 3
CV166=3 MP15DC Air Dryer 4
S0507 - Release Notes
===================================================
V-3 R-3:
===================================================
- description mispelling fix
- description brake squeal error fix
- remastered prime mover
- new horn pack "2nd Generation Switcher Horn Pack 2"
V-4 R-4:
===================================================
- Graham-White E-Bell 007 fix
V-5 R-5:
===================================================
- new prime mover volume mode Hide description more…