")}("width","220px",["/lib/bootstrap-select/css/bootstrap-select.min.css"],"rel=\u0022stylesheet\u0022 ");
This file is custom mapped for the Athearn SD70ACU Locomotives using a 58429 ESU LokSound 21MTC decoder and the factory Athearn Motherboards.
As there are 2 different startups on the SD70ACU, Air Start for NS and Electric Start for CP, we have created a file for each version:
12493.1 Canadian Pacific Electric Start Version with Nathan K3L Horn
12493.2 Norfolk Southern Air Start Version with Nathan K5LA Horn
In some cases the railroads varied on horns. Please use the list below to set the appropriate horn and bell for your roadname using CV163 and CV164.
The EMD SD70ACU is a 6-axle 4,300 hp (3,200 kW) diesel-electric locomotive originally built by General Motors Electro-Motive Division as an SD9043MAC, and rebuilt by Norfolk Southern and Progress Rail. They are operated by two railroads, Norfolk Southern railway and Canadian Pacific.
The SD70ACU began under Norfolk Southern, who rebuilt its EMD SD90MACs to this configuration at its shops in Altoona, Pennsylvania. The first locomotive entered the rebuilding process in September 2015, which was number 7299. As of 2019, all 110 units have been released into active service.
All of the SD70ACUs will be rebuilt with the latest EMD cab which meets current FRA crashworthiness standards. The Siemens electronics will be replaced with Mitsubishi electronics. The rebuild also includes the installation of Ultra Cab II, locomotive speed limiter (LSL), and cab signals. The trucks will be rebuilt only as needed and they are not getting traction motors swapped out.
In 2018, Canadian Pacific started a similar rebuild program with its long dormant SD90MAC fleet. Unlike NS, the work on these rebuilds was not be done in-house, but by Progress Rail at its Mayfield, Kentucky and Muncie, Indiana facilities.
In early 2021 CP bought 40 more SD90MACs from Union Pacific to continue the SD70ACU rebuild program. Some CP-patched, ex-Union Pacific SD90MACs have already been seen heading to Canada prior to rebuilding.
While not directly recorded from a SD70ACU we believe this to be an accurate representation using very similar recordings.
This project is a special notch based low idle with an automatic high idle version. It has a single turbo late (silenced) exhaust stack.
This ESU Sound file will operate like the prototype in terms of throttle notching. You will notice there is low and high idle, and once above notch 3 and back to Idle the prime mover will stay up in high idle for a period of time. Once in low idle throttling up to notch 1 or notch 2 and return to idle will stay in low idle.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover to a "Low Idle" and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cycle
CV168=3 - 9 Minute Cycle
CV168=4 - 12 Minute Cycle
Etc.....
CV168=255 - 765 Minute Cycle
3rd Gen Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie S-3L-R
CV163=1 Leslie S-5T-RRO-R
CV163=2 Nathan K-2H
CV163=3 Nathan K-3H-L
CV163=4 Nathan K-3L
CV163=5 Nathan K-3LA
CV163=6 Nathan K-5HL
CV163=7 Nathan K-5H-R24
CV163=8 Nathan K-5L
CV163=9 Nathan K-5LA
CV163=10 Nathan K-5LA-R24
CV163=11 Nathan K-5L-LA
CV163=12 Nathan K-5L-R24
CV163=13 Nathan P-3
CV163=14 Nathan P-5-R24
EMD 3rd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 049
CV164=1 EMD 8475495 Steel Bell 066
CV164=2 EMD 8475495 Steel Bell 068
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4 Hide description more…
The EMD SD90MAC is a model of 6,000 hp (4,470 kW)[1] C-C diesel-electric locomotive produced by General Motors Electro-Motive Division. It is, with the SD80MAC, one of the largest single-engined locomotives produced by EMD, surpassed only by the dual-engined DDA40X.
The SD9043MAC is the 4,300 hp (3,210 kW) variant, using a 16-cylinder 710G engine instead of the H-engine, which was originally intended as a temporary alternative while EMD tried to solve the H-engine's issues. However, the accompanying upgrade program was never utilized by its customers.
The SD90MAC's features include radial steering trucks with AC traction motors and an isolated safety cab which is mounted on shock absorbers to lessen vibrations in the cab. The SD90MAC, like the SD80MAC, SD70ACe, and SD70M-2, has a wide radiator section, nearly the entire width of the locomotive, which along with their size makes them easy to spot.
As of 2019, some SD90MACs are still in service on the Union Pacific. Norfolk Southern had rostered 110 SD90MAC locomotives purchased or traded from Union Pacific or the CIT Group respectively, that have now all been rebuilt as EMD SD70ACU locomotives. Canadian Pacific has also opted to convert their small fleet of long-stored SD90MACs into SD70ACUs as well.
This would be correct for the following locomotives:
SD70, SD70M, SD90/43MAC, SD70I,
Though recorded from an SD79043MAC it would be very close to the following locomotives:
SD50AF, GP60, GP60M, GP60B, SD60, SD60M, SD60I, SD60F, SD75M, SD75I, Austrailian National AN Class, SD70MAC, SD50X, GT46C, SD60E (upgraded to 710G3B from 710G3A)and others...
Recorded from a EMD SD9043MAC
This project is an isolation switch based low idle version. It has a single turbo late (silenced) exhaust stack.
File also contains a "low Idle" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to go to "regular idle" and begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
3rd Generation Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie RS-3L
CV163=1 Leslie RS-5T-RRO
CV163=2 Nathan K-2H
CV163=3 Nathan K-3HL
CV163=4 Nathan K-3L
CV163=5 Nathan K-3LA
CV163=6 Nathan K-5HL-R2
CV163=7 Nathan K-5H-R24
CV163=8 Nathan K-5L
CV163=9 Nathan K-5LA
CV163=10 Nathan K-5LA-R24
CV163=11 Nathan K-5LLA-R1L
CV163=12 Nathan K-5L-R24
CV163=13 Nathan P-3
CV163=14 Nathan P-5-R24
EMD 3rd Generation Bell Template Pack 3
Bells (SoundCV10):
CV164=0 Ekyrail E-Bell 001
CV164=1 UKM B443 Steel Bell 001
CV164=2 EMD 8475495 Steel Bell 068
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4
S0844 - Release Notes
===================================================
V-4 R-4:
===================================================
- New Prime Mover Volume Mode Hide description more…
If you download the designated file, you agree to be legally bound by the license given above.