Bulletin: EMD 16-710G3C LATE EXH T

Manufacturer: ESU, Item number: S0525, Version: V4-R4

The EMD 710 is a line of diesel engines built by Electro-Motive Diesel (EMD). Introduced in 1985, the 710 series replaced the earlier EMD 645 series. Since its introduction, EMD has continually upgraded the 710G diesel engine. Power output has increased from 3,800 horsepower on 1985's 16-710G3A to 4,500 horsepower on 2012's 16-710G3C-T2. Over the production span of certain locomotive models, upgraded engine models have been fitted when these became available. For example, an early 1994-built SD70MAC had a 16-710G3B, whereas a later 2003-built SD70MAC would have a 16-710G3C-T1.

In 2005 EMD was released a Tier 2 710 prime mover for thier upcoming SD70M-2 and SD70ACe models. The SD70M-2 is a DC traction version of the SD70ACe, and the two models are nearly identical in every other respect. Like the SD70ACe, the SD70M-2 models are equipped with the 16-710G3C-T2 prime mover which is rated at 4,300 horsepower. One of the main differences in the SD70M-2/SD70ACes from previous SD70s is the addition of Air Start. This loud burst of air in the start sequence is not present on most earlier EMD locomotives. All SD70M-2s and SD70ACes, except for the ones bought by CITX, are equipped with the Airchime model K5LLA air horn and an electronic bell. Due to this Air Start these locomotives have a period of High Idle just after start up to recharge the air and warm up the locomotive.

Locomotives:

SD70M-2, SD70ACe

Recorded from a Tacoma Rail EMD SD70ACE

This project has a notch based low idle with automatic high idle. It has a single turbo late (silenced) exhaust stack.

File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.

Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.

This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.

This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.

You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.

This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.

Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.

Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume

This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.

Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 1 Minute Cycle Engine On & 1 Minute Cycle Engine Off
CV168=2 - 2 Minute Cylcle Engine On & 2 Minute Cycle Engine Off
CV168=3 - 3 Minute Cylcle Engine On & 3 Minute Cycle Engine Off
CV168=4 - 4 Minute Cylcle Engine On & 4 Minute Cycle Engine Off
Etc.....
CV168=255 - 255 Minute Cycle

SD70ACE-SD70M-2 Horn Pack 1
Horns (SoundCV9):
CV163=0 Nathan K-5LLA-R1L
CV163=1 Nathan K-5LLA-R1L (2nd Gen)
CV163=2 Nathan K-5LLA-R1L (3rd Gen)
CV163=3 Nathan K-5LLA-R1L Ed2
CV163=4 Nathan K-5LLA-R1L (2nd Gen) Ed2
CV163=5 Nathan K-5LLA-R1L (3rd Gen) Ed2
CV163=6 Nathan K-5LLA-R1L Ed3
CV163=7 Nathan K-5HL-R2 Ed2
CV163=8 Nathan K-5HL-R2 (3rd Gen)
CV163=9 Nathan K-5HL-R2 (2nd Gen)
CV163=10 Nathan K-5LA-R24

EMD 3rd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 049
CV164=1 EMD 8475495 Steel Bell 066
CV164=2 EMD 8475495 Steel Bell 068
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009

Auto Bell:

Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.

We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.

To turn the feature OFF - Auto Bell OFF:

1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4

2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0

To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12

2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1


Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...

3rd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2

EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4

S0525 - Release Notes
===================================================

V-4 R-4:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- new horn pack "SD70ACE/SD70M-2 Horn Pack 1"
- new smart start timer update

KeyFunctionsSound slotsVolume CVsVolume values
F0Headlights Front/Rear
F1Bell428335
F2Horn3, 4275, 283225, 35
F3Coupler529160
F4Dynamic Brake6299100
F5Emergency Lights
F6Aux1-Aux2 Front Ditchlights Flashing by default
F7Flange Squeal2343530
F8Prime Mover, Traction Motor, Starting Delay1, 19, 25, 26259, 403, 451, 459225, 10, 60, 60
F9Drive Hold
F10Independent Brake1133930
F11Radiator Fan831540
F12Dimmer
F13Aux4-Aux5 Rear Ditchlights Flashing by default
F14Hand Brake1436335
F15Isolation Switch2141910
F16Air Dryer On Shutdown
F17Brake Set/Release Automatic2948330
F18Sanding Valve133558
F19Short Air Let Off2444350
F20Compressor730720
F21Air Dryer1738750
F22Cab Door1537155
F23Engine Compartment Doors1637935
F24Reverser Center2041110
F25Shutters Open/Closed3250720
F26Manual Notching Up / Run 8
F27Manual Notching Down / Coast
F28Manual Notching Logic2746720
F29Load
F30Automatic Brake1033130
F31Soundfader

Make sure that index CV31 is set to 16 and index CV32 is set to 1 before changing a volume CV.