Bulletin: GE 16-7FDL16Y2 LATE EXH HEP

Manufacturer: ESU, Item number: S0582, Version: V4-R2

The GE "Genesis" series of Locomotives was developed to be the main locomotives for Amtrak. Amtraks EMD F40PH locomotives were aging fast and GE came to the rescue with a more powerful and more fuel efficient design. Some P42 Locomotives were built with a Dual Mode capability utilizing a 3rd Rail shoe for collecting electricity. These engines run on the North East Corridor on Amtrak and on Metro North. The ESU version is the DC model which is much more common. It can be used to represent the P42s used by Amtrak, Via, NJT and Conn DOT. It can also be used in the non-electrified Areas of Metro North.

The P42 has a Very Specific Sound set. No Generic GE sound is correct for it. We have gone out of our way to make sure the sound we provide is as accurate as possible. We’ve even had the opportunity to take a cab in a P42 and take note of exactly how the engine was operated so that we could produce a sound that is absolutely true to the prototype.

This project is a normal idle version. It has a single late (silenced) exhaust stack.

File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.

Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.

You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.

This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.

This file has a Special feature providing the sounds and operation of the Head End Power unit. This is used on the prototype loco to provide electricity to the coaches as these locos are almost always used in passenger service.

To engage HEP you must be stopped in Idle. Pressing F26 (Shift 2) will engage the HEP unit and allow the prime mover to run at a higher RPM.

When in stations often the engineer will go into Standby mode to preserve fuel and to allow the noise levels to come down a little. Pressing F27 on the throttle once HEP has already been engaged will allow the prime mover to come down a little. Again this can only be done while sitting still as on the prototype there is not enough RPM to provide power to the coaches and traction motors at the same time in Standy Mode.

3rd Gen Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie S-3L-R
CV163=1 Leslie S-5T-RRO-R
CV163=2 Nathan K-2H
CV163=3 Nathan K-3H-L
CV163=4 Nathan K-3L
CV163=5 Nathan K-3LA
CV163=6 Nathan K-5HL
CV163=7 Nathan K-5H-R24
CV163=8 Nathan K-5L
CV163=9 Nathan K-5LA
CV163=10 Nathan K-5LA-R24
CV163=11 Nathan K-5L-LA
CV163=12 Nathan K-5L-R24
CV163=13 Nathan P-3
CV163=14 Nathan P-5-R24

GE Modern Auto Bell On/Off Trigger Template Pack 2
Bells (SoundCV10):
CV164=0 GE M 6731022A Steel Bell 031
CV164=1 GE M 6731022A Steel Bell 033
CV164=2 Graham-White E-Bell 001
CV164=3 Graham-White E-Bell 002
CV164=4 Graham-White E-Bell 008

Auto Bell:

Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.

We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.

To turn the feature OFF - Auto Bell OFF:

1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4

2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0

To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12

2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1


Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...

3rd Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Composition Shoe #2

GE Modern Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 AC4400CW Air Dryer 1
CV166=1 AC4400CW Air Dryer 2
CV166=2 AC4400CW Air Dryer 3
CV166=3 E4C6T Air Dryer 1

KeyFunctionsSound slotsVolume CVsVolume values
F0Headlights Front/Rear
F1Bell428380
F2Horn3, 4275, 283128, 80
F3Coupler529180
F4Dynamic Brake629960
F5DPU Mode
F6AUX1 + AUX2 + AUX5 + AUX6 (Ditchlights)
F7Flange Squeal2343540
F8Prime Mover, Traction Motor, Starting Delay, Reverser, Numberboards/Walkway/Ground lights - Aux3 - Aux41, 19, 25, 26259, 403, 451, 459100, 60, 60, 60
F9Drive Hold
F10Independent Brake1133970
F11Radiator Fan831540
F12Dimmer
F13Class Lights
F14Hand Brake1436370
F15Isolation Switch2141940
F16Air Dryer On Shutdown
F17Brake Set/Release Automatic2948370
F18Sanding Valve1335560
F19Short Air Let Off2444380
F20Compressor7307100
F21Air Dryer1738780
F22Cab Door1537180
F23Horn Sequence4, 16283, 37980, 128
F24Reverser Center2041160
F25Shutters Open/Closed3250730
F26Manual Notching Up / HEP Mode - Can only be engaged when stopped in Idle
F27Manual Notching Down / Standby Mode - Can only be engaged when stopped and HEP is on
F28Manual Notching Logic2746720
F29Load
F30Automatic Brake1033170
F31Soundfader

Make sure that index CV31 is set to 16 and index CV32 is set to 1 before changing a volume CV.