Manufacturer: ESU, Item number: S0735, Version: V5-R5
Introduced in 2012, General Electric's Tier 4 GEVo Series represents the latest in diesel-electric locomotive technology. The GE Tier 4 GEVo is designed to meet increasingly stringent Environmental Protection Agency (EPA) emissions regulations.
The EPA “Tier” emissions standards are a series, or Tiers, of allowable emissions levels based upon a locomotives’ date of manufacture. The highest and most stringent tier level, Tier 4, sets maximum allowable NOx and hydrocarbon emissions levels for locomotives built for domestic use 2015 onward.
While similar in appearance to previous GE GEVo designs, the Tier 4 models featured a longer frame compared to their predecessors. This allows for a larger radiator “cab” (GE refers to the various sections of the long hood as “cabs”), and a "hump" over the engine cab for advanced exhaust treatment equipment.
Initially, a boxy housing filled the entire roofline on the blue-painted field test/demonstrator units. Due to changes in treatment equipment and clearance issues, the "hump" would decrease in size and shape into a boxy compartment around the exhaust on initial production units. This culminated in an angled compartment surrounding the exhaust manifold on the latest production versions (2016+).
Despite boxier engine cab rooflines and a radically styled radiator cab, the basic Tier 4 design shares a family appearance with GE safety cab-equipped units going back to the DASH-9s of the 1990s. It even includes the same 12-cylinder GEVo-12 series prime mover and 4,400hp as its predecessor model.
The Tier 4 units have proven to be popular with the major railroads including BNSF Railway, Canadian National, CSX Transportation, Norfolk Southern, and Union Pacific. While GE has settled on a basic carbody design to keep production costs down, there are notable variations and detail differences due to customer specifications.
With many units built for railroads across the US and in Canada, the Tier 4 GEVo can be seen operating nationwide in a variety of assignments.
Recorded from a GE E4C6T
This project has an automatic low & high idle. It has a single late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
Gevo Horn Pack 1
Horns (SoundCV9):
CV163=0 Nathan K-5HL-R2
CV163=1 Nathan K-5HL-R2 (2nd Gen)
CV163=2 Nathan K-5HL-R2 (3rd Gen)
CV163=3 Nathan K-3LL-CA
CV163=4 Nathan K-12 Ed2
CV163=5 Nathan K-5HL-R2 Ed2
CV163=6 Nathan K-5HL-R2 (3rd Gen) Ed2
CV163=7 Nathan K-3LL-CA Ed2
CV163=8 Nathan K-12 Ed3
CV163=9 Nathan K-5HL-R2 Ed3
CV163=10 Nathan K-3LL-CA - Nathan K-12 Ed2 Directional
CV163=11 Nathan K-3LL-CA Ed2 - Nathan K-12 Ed3 Directional
CV163=12 Nathan K-3HL
CV163=13 Nathan K-5LLA-R1L
CV163=14 Nathan K-5LA-R24 Ed2
GE Modern Bell Template Pack 2
Bells (SoundCV10):
CV164=0 GE M 6731022A Steel Bell 031
CV164=1 GE M 6731022A Steel Bell 033
CV164=2 Graham-White E-Bell 001
CV164=3 Graham-White E-Bell 002
CV164=4 Graham-White E-Bell 008
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2
GE Modern Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 AC4400CW Air Dryer 1
CV166=1 AC4400CW Air Dryer 2
CV166=2 AC4400CW Air Dryer 3
CV166=3 E4C6T Air Dryer 1
S0735 - Release Notes
===================================================
V-5 R-5:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- new horn pack "Gevo Horn Pack 1"
Key | Functions | Sound slots | Volume CVs | Volume values |
---|---|---|---|---|
F0 | Headlights Front/Rear | |||
F1 | Bell | 4 | 283 | 40 |
F2 | Horn | 3, 4 | 275, 283 | 225, 40 |
F3 | Coupler | 5 | 291 | 60 |
F4 | Dynamic Brake | 6 | 299 | 30 |
F5 | Emergency Lights | |||
F6 | Aux1-Aux2 Front Ditchlights Flashing by default | |||
F7 | Flange Squeal | 23 | 435 | 30 |
F8 | Prime Mover, Traction Motor, Starting Delay | 1, 19, 25, 26 | 259, 403, 451, 459 | 225, 20, 60, 60 |
F9 | Drive Hold | |||
F10 | Independent Brake | 11 | 339 | 30 |
F11 | Radiator Fan | 8 | 315 | 40 |
F12 | Dimmer | |||
F13 | Aux4-Aux5 Rear Ditchlights Flashing by default | |||
F14 | Hand Brake | 14 | 363 | 40 |
F15 | Isolation Switch | 21 | 419 | 10 |
F16 | Air Dryer On Shutdown | |||
F17 | Brake Set/Release Automatic | 29 | 483 | 30 |
F18 | Sanding Valve | 13 | 355 | 20 |
F19 | Short Air Let Off | 24 | 443 | 30 |
F20 | Compressor | 7 | 307 | 20 |
F21 | Air Dryer | 17 | 387 | 30 |
F22 | Cab Door | 15 | 371 | 30 |
F23 | Engine Compartment Doors | 16 | 379 | 30 |
F24 | Reverser Center | 20 | 411 | 20 |
F25 | Shutters Open/Closed | 32 | 507 | 20 |
F26 | Manual Notching Up / Run 8 | |||
F27 | Manual Notching Down / Coast | |||
F28 | Manual Notching Logic | 27 | 467 | 20 |
F29 | Load | |||
F30 | Automatic Brake | 10 | 331 | 30 |
F31 | Soundfader |
Make sure that index CV31 is set to 16 and index CV32 is set to 1 before changing a volume CV.