")}("width","220px",["/lib/bootstrap-select/css/bootstrap-select.min.css"],"rel=\u0022stylesheet\u0022 ");
GE Evolution 12cyl "GEVO" Locomotives have a 4 stoke diesel engine and have been designed to be more efficient and more emission friendly than previous models. Evolution Series locomotives are equipped with either AC or DC traction motors, depending on the customer's preference, though admittedly there is little sound difference if any between the two.
All early GEVOs were delivered with the Nathan Airchime K5HL air horn. Later GEVOs started to recieve a slightly different K5HLL horn. Most if not all have been delivered with a Graham-White 373 E-Bell. This E-Bell is tied to the horn circuit in the locomotive and will play automatically when the horn is played. The ESU version also has this new feature. The bell can be activated by either pressing F1 or by pressing the horn using F2. The "Auto-Bell" can be turned off by removing the the Auto-Bell sound slot from F2.
Another feature of the prototype is "Smart Start". For the sake of both emissions and fuel savings all GEVOs have been built with an auto shutdown/auto start feature. After the loco has been idle for a period time, the engine will shut down on its own. If the prime mover cools to a certain temperature the loco will automatically start again to keep from freezing.
Recorded from a GE ES44AC
This project has an automatic low & high idle. It has a single late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
Gevo Horn Pack 1
Horns (SoundCV9):
CV163=0 Nathan K-5HL-R2
CV163=1 Nathan K-5HL-R2 (2nd Gen)
CV163=2 Nathan K-5HL-R2 (3rd Gen)
CV163=3 Nathan K-3LL-CA
CV163=4 Nathan K-12 Ed2
CV163=5 Nathan K-5HL-R2 Ed2
CV163=6 Nathan K-5HL-R2 (3rd Gen) Ed2
CV163=7 Nathan K-3LL-CA Ed2
CV163=8 Nathan K-12 Ed3
CV163=9 Nathan K-5HL-R2 Ed3
CV163=10 Nathan K-3LL-CA - Nathan K-12 Ed2 Directional
CV163=11 Nathan K-3LL-CA Ed2 - Nathan K-12 Ed3 Directional
CV163=12 Nathan K-3HL
CV163=13 Nathan K-5LLA-R1L
CV163=14 Nathan K-5LA-R24 Ed2
GE Modern Bell Template Pack 1
Bells (SoundCV10):
CV164=0 GE M 6731022A Steel Bell 026
CV164=1 GE M 6731022A Steel Bell 028
CV164=2 GE M 6731022A Steel Bell 030
CV164=3 Graham-White E-Bell 001
CV164=4 Graham-White E-Bell 002
CV164=5 Graham-White E-Bell 008
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2
GE Modern Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 AC4400CW Air Dryer 1
CV166=1 AC4400CW Air Dryer 2
CV166=2 AC4400CW Air Dryer 3
CV166=3 E4C6T Air Dryer 1
Gevo Traction Motor Pack 1
Change the sound configuration of the traction motor sound slot
CV31 = 16, CV32 = 1
----------------------
CV455 = 0 AC4400CW GE GEB13 Traction Motor 1
Change the sound configuration of the traction motor sound slot
CV31 = 16, CV32 = 1
----------------------
CV455=1 ES40DC GE-752AH Traction Motor 1
S0523 - Release Notes
===================================================
V-4 R-3:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- new horn pack "Gevo Horn Pack 1"
- new traction motor pack with selectable AC and DC motors "Gevo Traction Motor Pack 1"
V-5 R-4:
===================================================
- New Prime Mover Volume Mode
- Correct Dynamic Brake Using Normal Idle Instead Of High Idle
V-6 R-5:
===================================================
- prime mover engine start volume increase Hide description more…
The ALCO 251 prime mover was the most popular and abundant prime mover ever made by the company. While it proved to be quite successful, it sadly outlived its original manufacturer, ALCO who closed their doors in 1969. The 251 prime mover is actually still available to purchase today from Fairbanks Morse for use in Marine, Generator, and locomotive uses.
The 2000 horsepower 12cyl version of the 251C could be found in the following locomotives:
M420W, M420B, M420R, M420TR, HR-412, M424, RS-32, C420, 45 Class, 442 Class, 600 Class, 700 Class, A-321
The 2000 Horsepower 12cyl 251B version was extremely close to 251C in the way that is sounded. The 12cyl 251B can be found in the following Locomotives:
RS-11, RSD-12, RS-18, RS-36, FPA-4, FPB-4, RSC-14, FD-6, FD-7, FD-9, RSD-16, DL-560, 44 Class, 930 Class
The 12cyl 251 was also used in many rebuilt locomotives including:
RS-3m, C424m, and others...
Recorded from a ALCO M-420W
This project is a normal idle version. It has a single exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
1st Generation Horn Pack 7
Horns (SoundCV9):
CV163=0 IEC-Holden K-3L
CV163=1 IEC-Holden K-3L-R3
CV163=2 Nathan M-3H
CV163=3 Nathan M-3H Ed2
CV163=4 Nathan M-3H-R2
CV163=5 Nathan M-3-RT1
CV163=6 Nathan K-3H
CV163=7 Nathan K-3H-R1
CV163=8 Nathan K-5L
CV163=9 Nathan K-5H Ed2
CV163=10 Nathan K-3L-R2
CV163=11 Nathan K-3L-R3
CV163=12 Nathan P-3 Ed2
CV163=13 Prime PM-990
ALCO Bell Template Pack 2
Bells (SoundCV10):
CV164=0 ALCO Bronze Bell 001
CV164=1 ALCO Bronze Bell 002
CV164=2 ALCO Bronze Bell 008
CV164=3 ALCO Bronze Bell 011
CV164=4 Transtronic E-Bell 001
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
1st Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Cast Iron Shoe #1
ALCO Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 RS-18 Air Dryer 3
CV166=1 RS-18Air Dryer 4
CV166=2 RS-18 Air Dryer 5
CV166=3 C-425 Air Dryer 2
S0714 - Release Notes
===================================================
V-2 R-2:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- new horn pack "1st Generation Pack 7" Hide description more…
The EMD GP22ECO is a 2,150 hp (1,600 kW) B-B road switcher diesel-electric locomotive rebuilt by Electro-Motive Diesel and Norfolk Southern's Juniata Shops. Initially EMD built two GP22ECO demonstrators, one based on a GP9 and one based on a GP40,[1] but thus far all orders have been for conversions based on EMD GP40 and EMD GP40-2 series locomotives. The rebuild involves replacing the existing prime mover with an EPA Tier-II-compliant turbocharged V8 710G3A, with Electronic fuel injection. The prime mover is mated to an AR10 alternator for traction power, a CA6 alternator for control power, and a computerized control system. Applying this to a 6-axle locomotive results in a SD22ECO. Some 6-axle locomotives could alternately be converted into a SD32ECO, using a 3,150 hp (2,350 kW) V12 instead.
When applied to GP40 or GP40-2 series locomotives, this conversion does not alter the external appearance of the locomotive, although the conversion of the GP9-based demonstrator required extensive changes to the long hood. The GP22ECO offers customers a 'factory' upgrade of existing locomotives.
Norfolk Southern's units were rebuilt from GP38AC units. They also feature electrical, mechanical, and emissions improvements.
Recorded from a EMD GP22ECO
This project has a notch based low idle. It has a single turbo late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
3rd Generation Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie RS-3L
CV163=1 Leslie RS-5T-RRO
CV163=2 Nathan K-2H
CV163=3 Nathan K-3HL
CV163=4 Nathan K-3L
CV163=5 Nathan K-3LA
CV163=6 Nathan K-5HL-R2
CV163=7 Nathan K-5H-R24
CV163=8 Nathan K-5L
CV163=9 Nathan K-5LA
CV163=10 Nathan K-5LA-R24
CV163=11 Nathan K-5LLA-R1L
CV163=12 Nathan K-5L-R24
CV163=13 Nathan P-3
CV163=14 Nathan P-5-R24
EMD 3rd Generation Bell Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 037
CV164=1 EMD 8475495 Steel Bell 046
CV164=2 EMD 8475495 Steel Bell 056
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1 (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1 (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4
S0821 - Release Notes
===================================================
V-4 R-4:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- auto bell not working fix
V-5 R-5:
===================================================
- Prime mover volume selection mode
V-6 R-6:
===================================================
- Prime mover volume selection mode fix Hide description more…
The 567 prime mover is a line of medium-speed diesel engines manufactured by GM Electro-Motive Division. They were used in many EMD locomotives from 1938-1966 when it was replaced by the EMD 645. The 567 proved to be exceptionally successful in passenger, switching, freight, marine and stationary services. The 16 cylinder 567C variation could be found in the following locomotives:
FP7, FP9, FL9, FT, F2, F3, F7, F9, GP7, GP8, GP9, GP10, GP11, BL2, GP18, GP28, SD7, SD9, SD18
Recorded from a EMD GP9
This project is a normal idle version. It has 2 exhaust stacks.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
1st Generation Horn Pack 2
Horns (SoundCV9):
CV163=0 Leslie S-3J
CV163=1 Leslie S-3K-R
CV163=2 Leslie RS-3L
CV163=3 Leslie S-5T-F
CV163=4 Leslie S-5T-R
CV163=5 Leslie S-5T-RRO
CV163=6 Leslie SL-4T
CV163=7 Nathan K-5LA
CV163=8 Nathan M-3H-R2
CV163=9 Nathan M-3-R1
CV163=10 Nathan M-3-RT1
CV163=11 Nathan M-5-R24
CV163=12 Wabco A-2
EMD 1st Generation Bell Template Pack 3
Bells (SoundCV10):
CV164=0 EMD 8004156 Bronze Bell 014
CV164=1 EMD 8475495 Steel Bell 013
CV164=2 EMD 8004156 Bronze Bell 015
CV164=3 EMD 8475495 Steel Bell 024
CV164=4 EMD 8475495 Steel Bell 028
CV164=5 Graham-White E-Bell 005
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
1st Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV165=1 Cast Iron Shoe
EMD 1st Generation Air Dryer Template Pack 2
Air Dryer (SoundCV12)
CV166=0 GP9 Air Dryer 1
CV166=1 GP9 Air Dryer 2
CV166=1 GP8 Air Dryer 1
CV166=1 CF7 Air Dryer 1
S0768 - Release Notes
===================================================
V-4 R-4:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- updated prime mover comment
V-5 R-5:
===================================================
- prime mover volume selection mode Hide description more…
The 567 prime mover is a line of medium-speed diesel engines manufactured by GM Electro-Motive Division. They were used in many EMD locomotives from 1938-1966 when it was replaced by the EMD 645. The 567 proved to be exceptionally successful in passenger, switching, freight, marine and stationary services. The 16 cylinder 567D3 variation was used in the following...
Locomotives:
GP30, SD24
Although the following locomotives do not have a 567D3, they are in the 567D family and this sound file would be very close for the following...
GP20, GP35, SD35, SDP35
Recorded from a EMD GP30
This project is a normal idle version. It has a single turbo early exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
1st Generation Horn Pack 6
Horns (SoundCV9):
CV163=0 Leslie SU-3L-LR
CV163=1 Leslie S-2M Ed2
CV163=2 Leslie S-25
CV163=3 Leslie S-2M-RB + Leslie S-25 Combo
CV163=4 Leslie S-2A
CV163=5 Leslie SU-3B-LF
CV163=6 Leslie SU-3B-LR + Leslie S-2A Combo
CV163=7 Leslie SU-3B-LRO + Leslie S-2A-O Combo
CV163=8 Leslie S-2A-R
CV163=9 Leslie S-2M-R
CV163=10 Leslie S-2M-RBO + Leslie S-2A-R Combo
CV163=11 Leslie SU-3L-LRO + Leslie S-2A-O Combo
CV163=12 Nathan P-3-OC Ed2
CV163=13 Nathan P-5-OC Ed2
CV163=14 IEC-Holden K-3L
EMD 1st Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8004156 Bronze Bell 011
CV164=1 EMD 8475495 Steel Bell 007
CV164=2 EMD 8004156 Bronze Bell 012
CV164=3 EMD 8475495 Steel Bell 009
CV164=4 EMD 8004156 Bronze Bell 013
CV164=5 EMD 8475495 Steel Bell 010
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
1st Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV165=1 Cast Iron Shoe
EMD 1st Generation Air Dryer Template Pack 2
Air Dryer (SoundCV12)
CV166=0 GP9 Air Dryer 1
CV166=1 GP9 Air Dryer 2
CV166=1 GP8 Air Dryer 1
CV166=1 CF7 Air Dryer 1
S0758 - Release Notes
===================================================
V-4 R-4:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- new horn pack "1st Generation Pack 6"
- updated prime mover comment
V-5 R-5:
===================================================
- prime mover volume selection mode Hide description more…
The EMD 567 is a line of large medium-speed diesel engines built by General Motors' Electro-Motive Division. The EMD 567 16cyl Prime Mover was one of the most widely used Prime Movers in the world and was used from 1938 until its replacement n 1966. From F-Units to Geeps this popular power house can still be found in many locomotives riding the rails today. Alle 567 engines are two-stroke V-engines with an angle of 45° between cylinder banks, a bore of 8,5 in (216mm) and a stroke of 10 in (254mm). The 567BC was roots blown and had a power output of 1500 hp (1119 kW).
This 16cyl 567BC sound file would be appropriate for the following locomotives:
FP7, FP9, FL9, FT, F2, F3, F7, F9, GP7, GP8, GP9, GP10, GP11, BL2, GP18, GP28, SD7, SD9, SD18, SD28
Recorded from a EMD FP7A
This project is a normal idle version. It has 2 exhaust stacks.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
1st Generation Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie A-125
CV163=1 Leslie A-200
CV163=2 Leslie S-2M
CV163=3 Leslie S-3K
CV163=4 Leslie S-3L
CV163=5 Leslie S-5T
CV163=6 Nathan M-3
CV163=7 Nathan M-3H
CV163=8 Nathan M-5
CV163=9 Nathan P-5-OC
CV163=10 Nathan P-5-R24-OC
CV163=11 Nathan P-3-OC
CV163=12 Nathan P-3-R4-OC
CV163=13 Nathan P-5A-OC
CV163=14 Wabco E-2
EMD 1st Generation Bell Template Pack 3
Bells (SoundCV10):
CV164=0 EMD 8004156 Bronze Bell 014
CV164=1 EMD 8475495 Steel Bell 013
CV164=2 EMD 8004156 Bronze Bell 015
CV164=3 EMD 8475495 Steel Bell 024
CV164=4 EMD 8475495 Steel Bell 028
CV164=5 Graham-White E-Bell 005
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
1st Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV165=1 Cast Iron Shoe
EMD 1st Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 F7A Air Dryer 1
CV166=1 GP7 Air Dryer 1
CV166=1 GP7U Air Dryer 1
CV166=1 GP7U Air Dryer 2
S0746 - Release Notes
===================================================
V-4 R-4:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- updated prime mover comment
V-5 R-5:
===================================================
- prime mover volume selection mode Hide description more…
In the Mid 1980s GE changed it's 16cyl FDL design to include a different exhaust silencer, a new electric compressor often known as the "Whoop compressor" and changed some of the electronics of their locomotives. These differences among a few other led to a distinct change in the sounds from the GE 16cyl FDL often found from the U25Bs on through the Dash-7 series of the Locomotives.
Keeping in tradition with GE's locomotive series nicknames beginning with the "Dash 7" of the 1970s, the C44-9W was dubbed the Dash 9 upon its debut in 1993.
The "Dash-9" GE 16-7FDL16Y2 Prime mover can be found in the following Locos:
Dash 9-40C, Dash 9-40CW, Dash 9-44CW, C44-9WL, C44-9WM
It is also very close to the following locos:
AC44C6M, AC44C4M, Dash 8-39B, Dash 8 40-B, Dash 8-40BW, Dash 8-39C, Dash 8-40C, Dash 8-40CM, Dash 8-40CW, Dash 8-41CW, Dash 8-44CW, C38EMi, C38AChe, AC4400CW
Some AC6000CW were built with 7FDL-16cyls and were later converted to 7HDL-16cyl. Some were never converted. Please refer to the prototype for reference.
Recorded from a GE CW40-9
This project has an automatic low & high idle. It has a single late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
3rd Generation Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie RS-3L
CV163=1 Leslie RS-5T-RRO
CV163=2 Nathan K-2H
CV163=3 Nathan K-3HL
CV163=4 Nathan K-3L
CV163=5 Nathan K-3LA
CV163=6 Nathan K-5HL-R2
CV163=7 Nathan K-5H-R24
CV163=8 Nathan K-5L
CV163=9 Nathan K-5LA
CV163=10 Nathan K-5LA-R24
CV163=11 Nathan K-5LLA-R1L
CV163=12 Nathan K-5L-R24
CV163=13 Nathan P-3
CV163=14 Nathan P-5-R24
GE Modern Bell Template Pack 1
Bells (SoundCV10):
CV164=0 GE M 6731022A Steel Bell 026
CV164=1 GE M 6731022A Steel Bell 028
CV164=2 GE M 6731022A Steel Bell 030
CV164=3 Graham-White E-Bell 001
CV164=4 Graham-White E-Bell 002
CV164=5 Graham-White E-Bell 008
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2
GE Modern Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 AC4400CW Air Dryer 1
CV166=1 AC4400CW Air Dryer 2
CV166=2 AC4400CW Air Dryer 3
CV166=3 E4C6T Air Dryer 1
S0772 - Release Notes
===================================================
V-9 R-6:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- New Prime Mover Volume Mode
- Correct Dynamic Brake Using Normal Idle Instead Of High Idle Hide description more…
The EMD 645 series engine was an evolution of the earlier 567 series and a precursor to the later 710 series. When the 645 prime mover entered production in 1965, a large series of new locomotive models were introduced. The turbocharged version was used in EMD's 40 Series (GP40, SD40 and SD45) in 3,000 horsepower (2,200 kW), sixteen-cylinder form and in 3,600 horsepower (2,700 kW), twenty-cylinder form. EMD also introduced the Roots-blown 38 Series (GP38, SD38) and turbocharged, twelve-cylinder 39 Series (GP39, SD39). All of these locomotive models extensively share common components and subsystems, thereby significantly reducing cost and increasing interchangeability. The GP38-2 and SD40-2 became the most popular models of the series and among the most popular locomotive models ever built.
This 16cyl 645E3B Turbo sound file would be appropriate for the following locomotives:
SD40-2W, GP40, GP40P, GP40P-2, SD40A, SD45T-2, GP40-2, GP40X, SD40X, SD40-2, F40C, F40PH, F40PH-2, F40PH-2M, SDP40F, SD40-2F
Export locomotives:
GT26MC, GT26CW, GT26CW-1, GT26CW-2, GT26CU-2
Recorded from a F40PHR
This project is a normal idle version. It has a single turbo late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
2nd Generation Horn Pack 8
Horns (SoundCV9):
CV163=0 Leslie RS-5T-RRO Ed2
CV163=1 Leslie RSU-3L-LRO
CV163=2 Leslie RS-3K
CV163=3 Leslie RSL-3L-RO
CV163=4 Leslie S-5T-RRO Ed2
CV163=5 Leslie S-3L-R
CV163=6 IEC-Holden K-3L
CV163=7 IEC-Holden K-3L-R3
CV163=8 Nathan P-3 Ed2
CV163=9 Nathan P-5 Ed2
CV163=10 Nathan K-3HA-R2
CV163=11 Nathan K-3LA-R4
CV163=12 Nathan K-5LA Ed2
CV163=13 Nathan K-5LA-R23 Ed2
CV163=14 Nathan K-5LA-R24 Ed2
EMD 2nd Generation Bell Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 003
CV164=1 EMD 8004156 Bronze Bell 003
CV164=2 UKM B443 Steel Bell 001
CV164=3 Graham-White E-Bell 004
CV164=4 Transtronic E-Bell 001
CV164=5 WC Hayes 0333 M-Bell 001
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV165=1 Cast Iron Shoe
EMD 2nd Generation Air Dryer Template Pack 5
Air Dryer (SoundCV12)
CV166=0 GP40-2 Air Dryer 1
CV166=1 GP40-2 Air Dryer 2
CV166=2 GP40 Air Dryer 1
CV166=3 GP40 Air Dryer 2
S0765 - Release Notes
===================================================
V-3 R-3:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- new horn pack "2nd Generation Pack 8"
V-4 R-4:
===================================================
- Prime mover volume selection mode Hide description more…
The EMD GP59 is a 4-axle diesel road switcher locomotive model built by General Motors Electro-Motive Division between 1985 and 1989. Power was provided by a 12-cylinder EMD 710G3A diesel engine, which could produce 3,000 horsepower (2,200 kW). This locomotive shared the same common frame with the EMD GP60, giving it an overall length of 59 feet 9 inches (18.21 m). It featured a 3,700-US-gallon (14,000 l; 3,100 imp gal) fuel tank. 36 examples of this locomotive were built including three demonstrators. Norfolk Southern placed the only order for the GP59 and also acquired the three demonstrators which featured an aerodynamic cab.
In 2011 Norfolk Southern began a program to upgrade their fleet of GP59s, the only GP59s operating anywhere. The first one was not released until March 2013 as NS 4650 GP59E. The GP59E features a new EM2000 microprocessor, an all-new electrical cabinet with SmartStart auto start/stop, rebuilt 12-710G3C-BC prime-mover with EMDEC EUI system, NS-designed split cooling, the NS Admiral cab with cab signals, LSL, and CCB26 electronic brake valve. The GP59E is set up to operate with NS class RP-M4C road slugs.
While the only Road Switcher in the US to use the 12cyl EMD 710 prime mover, other locomotives did use it around the world.
This 12cyl 710 with Turbo sound file would be appropriate for the following locomotives:
GP59, F59PH - HEP Equipped - Use ESU file Number S0573, F59PHI - HEP Equipped - Use ESU file Number S0573, Australian National DL class, New South Wales 82 Class, SD32ECO, British Rail Class 66 , British Rail Class 67, Irish Rail 201 Class, RENFE Class 334, EMD DE/DM30AC, Euro 3000, WAGR S class (diesel) , Downer EDI Rail GT42CU AC, Downer EDI Rail JT42C-D
Recorded from a EMD GP59
This project is a normal idle version. It has a single turbo late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
3rd Generation Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie RS-3L
CV163=1 Leslie RS-5T-RRO
CV163=2 Nathan K-2H
CV163=3 Nathan K-3HL
CV163=4 Nathan K-3L
CV163=5 Nathan K-3LA
CV163=6 Nathan K-5HL-R2
CV163=7 Nathan K-5H-R24
CV163=8 Nathan K-5L
CV163=9 Nathan K-5LA
CV163=10 Nathan K-5LA-R24
CV163=11 Nathan K-5LLA-R1L
CV163=12 Nathan K-5L-R24
CV163=13 Nathan P-3
CV163=14 Nathan P-5-R24
EMD 3rd Generation Bell Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 037
CV164=1 EMD 8475495 Steel Bell 046
CV164=2 EMD 8475495 Steel Bell 056
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4
S0572 - Release Notes
===================================================
V-8 R-7:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- updated prime mover comment
V-9 R-8:
===================================================
- Prime mover volume selection mode
Hide description more…
The GE FDL-16 prime mover was first used in 1959 in the General Electric U25B locomotive. Over the years little changed in terms of sound until the "Dash-8" series of GE locomotives was introduced. Known for their throaty chug and shaft driven compressor (rather than the more modern “Whoop” electric compressor) , the following GE locomotives used the early 16cyl FDL prime mover:
U25B, U28B, U30B, U33B, U36B, U25C, U28C, U28CG, U30C, U30CG, P30CH, U34CH, U33C, U36C, B30-7, B36-7, C30-7, C36-7
Recorded from a GE U25B
This project is a normal idle version. It has a single early exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
1st Generation Horn Pack 2
Horns (SoundCV9):
CV163=0 Leslie S-3J
CV163=1 Leslie S-3K-R
CV163=2 Leslie RS-3L
CV163=3 Leslie S-5T-F
CV163=4 Leslie S-5T-R
CV163=5 Leslie S-5T-RRO
CV163=6 Leslie SL-4T
CV163=7 Nathan K-5LA
CV163=8 Nathan M-3H-R2
CV163=9 Nathan M-3-R1
CV163=10 Nathan M-3-RT1
CV163=11 Nathan M-5-R24
CV163=12 Wabco A-2
GE U-Boats Bell Template Pack 1
Bells (SoundCV10):
CV164=0 GE M 6731022A Steel Bell 004
CV164=1 GE M 6731022A Steel Bell 005
CV164=2 GE M 6731022A Steel Bell 009
CV164=3 GE M 6731022A Steel Bell 021
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
1st Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Cast Iron Shoe #1
GE U-Boats Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 U23B Air Dryer 1
CV166=1 U23B Air Dryer 2
CV166=2 U30C Air Dryer 1
CV166=3 U36B Air Dryer 1
S0545 - Release Notes
===================================================
V-3 R-3:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- updated prime mover comment
V-4 R-4:
===================================================
- Prime mover volume selection mode
Hide description more…
If you download the designated file, you agree to be legally bound by the license given above.