")}("width","220px",["/lib/bootstrap-select/css/bootstrap-select.min.css"],"rel=\u0022stylesheet\u0022 ");
The MPXpress line of locomotives were the first production passenger locomotives to meet EPA Tier 1 and Tier 2 emissions regulations, as well as FRA safety regulations regarding crashworthiness and fire safety. Numerous public transit agencies in Canada and the United States have ordered MPXpress locomotives for their commuter rail services. To date only GO Transit and Sounder Commuter Rail in Seattlehave MP40PH-3C in Service.
The prime mover used in the MP40PH-3C is a EMD 16-710GB. The Prototype has a seperate HEP unit for providing Power to the Passengers. This sound is also available in the in this file as a user dependant function that can turned on and off as needed. (Usually if 2 engines are used only the engine closest to the cars will have the HEP unit running)
These Locomotives are used Daily in "Push-Pull" service and are set up to do so as default in this decoder as well. Operating Front and rear red lights and Headlight/Ditchlights are set accordingly as default.
This project is an isolation switch based low idle version. It has a single turbo late (silenced) exhaust stack.
File also contains a "low Idle" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to go to "regular idle" and begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file has a Special feature providing the sounds and operation of the Head End Power unit. This is used on the prototype loco to provide electricity to the coaches as these locos are almost always used in passenger service.
To engage HEP you must be stopped in Idle. Pressing F7 (Shift 2) will engage the HEP unit and allow the prime mover to run at a higher RPM.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
The GO Transit MPI MP40PH-3C were delivered with Nathan K5LA airhorns. In Jan 2008 a Canadian Transport mandate required all passenger
locomotives (or any trains that go above 65mph) use a new horn type and pitches. Nathan Airchime created the K5-CA-LS - THREE CHIME SOFT (NORMAL) AND FIVE CHIME LOUD (EMERGENCY). This is a split manifold horn capable of playing only 3 lower pitched bells in normal use and all 5 for emergencies. These horns intentionally sound "bad" to alert people of the train. We have also included the Kockum Sonics Tyfon MKTH 75-5 Chime CA which sounds VERY MUCH like the emergency horn of the Nathan K5-CA-LS
3rd Gen Horn Pack 1
Horns (SoundCV9):
CV163=0 Nathan K-5LA AMTK ALC-42 Full Air *
CV163=1 Kockum Sonics Tyfon MKTH 75-5 Chime CA *
CV163=2 Nathan K-5LA AMTK ALC-42 Ed2 Full Air *
CV163=3 Kockum Sonics Tyfon MKTH 75-5 Chime CA *
CV163=4 Nathan K-5LA*
CV163=5 Nathan K-5LA-R24*
CV163=6 Nathan K-5L-LA *
CV163=7 Nathan K-5LA Amtrak*
CV163=8 Nathan K5-CA-LS Horn - GO Emergency *
CV163=9 Nathan K5-CA-LS Half Air Horn *
Cv163=10 Nathan K5-CA-LS Half Air Horn Ed2 *
EMD 3rd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 049
CV164=1 EMD 8475495 Steel Bell 066
CV164=2 EMD 8475495 Steel Bell 068
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4 Hide description more…
The EMD 710 is a line of diesel engines built by Electro-Motive Diesel (EMD). Introduced in 1985, the 710 series replaced the earlier EMD 645 series. Since its introduction, EMD has continually upgraded the 710G diesel engine. Power output has increased from 3,800 horsepower on 1985's 16-710G3A to 4,500 horsepower on 2012's 16-710G3C-T2. Over the production span of certain locomotive models, upgraded engine models have been fitted when these became available. For example, an early 1994-built SD70MAC had a 16-710G3B, whereas a later 2003-built SD70MAC would have a 16-710G3C-T1.
In 2005 EMD was released a Tier 2 710 prime mover for thier upcoming SD70M-2 and SD70ACe models. The SD70M-2 is a DC traction version of the SD70ACe, and the two models are nearly identical in every other respect. Like the SD70ACe, the SD70M-2 models are equipped with the 16-710G3C-T2 prime mover which is rated at 4,300 horsepower. One of the main differences in the SD70M-2/SD70ACes from previous SD70s is the addition of Air Start. This loud burst of air in the start sequence is not present on most earlier EMD locomotives. All SD70M-2s and SD70ACes, except for the ones bought by CITX, are equipped with the Airchime model K5LLA air horn and an electronic bell. Due to this Air Start these locomotives have a period of High Idle just after start up to recharge the air and warm up the locomotive.
Locomotives:
SD70M-2, SD70ACe
Recorded from a Tacoma Rail EMD SD70ACE
This project has a notch based low idle with automatic high idle. It has a single turbo late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 1 Minute Cycle Engine On & 1 Minute Cycle Engine Off
CV168=2 - 2 Minute Cylcle Engine On & 2 Minute Cycle Engine Off
CV168=3 - 3 Minute Cylcle Engine On & 3 Minute Cycle Engine Off
CV168=4 - 4 Minute Cylcle Engine On & 4 Minute Cycle Engine Off
Etc.....
CV168=255 - 255 Minute Cycle
SD70ACE-SD70M-2 Horn Pack 1
Horns (SoundCV9):
CV163=0 Nathan K-5LLA-R1L
CV163=1 Nathan K-5LLA-R1L (2nd Gen)
CV163=2 Nathan K-5LLA-R1L (3rd Gen)
CV163=3 Nathan K-5LLA-R1L Ed2
CV163=4 Nathan K-5LLA-R1L (2nd Gen) Ed2
CV163=5 Nathan K-5LLA-R1L (3rd Gen) Ed2
CV163=6 Nathan K-5LLA-R1L Ed3
CV163=7 Nathan K-5HL-R2 Ed2
CV163=8 Nathan K-5HL-R2 (3rd Gen)
CV163=9 Nathan K-5HL-R2 (2nd Gen)
CV163=10 Nathan K-5LA-R24
EMD 3rd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 049
CV164=1 EMD 8475495 Steel Bell 066
CV164=2 EMD 8475495 Steel Bell 068
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4
S0525 - Release Notes
===================================================
V-4 R-4:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- new horn pack "SD70ACE/SD70M-2 Horn Pack 1"
- new smart start timer update Hide description more…
The EMD 710 is a line of diesel engines built by Electro-Motive Diesel (EMD). Introduced in 1985, the 710 series replaced the earlier EMD 645 series. Since its introduction, EMD has continually upgraded the 710G diesel engine. Power output has increased from 3,800 horsepower on 1985's 16-710G3A to 4,500 horsepower on 2012's 16-710G3C-T2. Over the production span of certain locomotive models, upgraded engine models have been fitted when these became available. For example, an early 1994-built SD70MAC had a 16-710G3B, whereas a later 2003-built SD70MAC would have a 16-710G3C-T1.
In 2005 EMD was released a Tier 2 710 prime mover for thier upcoming SD70M-2 and SD70ACe models. The SD70M-2 is a DC traction version of the SD70ACe, and the two models are nearly identical in every other respect. Like the SD70ACe, the SD70M-2 models are equipped with the 16-710G3C-T2 prime mover which is rated at 4,300 horsepower. One of the main differences in the SD70M-2/SD70ACes from previous SD70s is the addition of Air Start. This loud burst of air in the start sequence is not present on most earlier EMD locomotives. All SD70M-2s and SD70ACes, except for the ones bought by CITX, are equipped with the Airchime model K5LLA air horn and an electronic bell. Due to this Air Start these locomotives have a period of High Idle just after start up to recharge the air and warm up the locomotive.
Locomotives:
SD70M-2, SD70ACe
Recorded from a Tacoma Rail EMD SD70ACE
This project has a notch based low idle with automatic high idle. It has a single turbo late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 1 Minute Cycle Engine On & 1 Minute Cycle Engine Off
CV168=2 - 2 Minute Cylcle Engine On & 2 Minute Cycle Engine Off
CV168=3 - 3 Minute Cylcle Engine On & 3 Minute Cycle Engine Off
CV168=4 - 4 Minute Cylcle Engine On & 4 Minute Cycle Engine Off
Etc.....
CV168=255 - 255 Minute Cycle
SD70ACE-SD70M-2 Horn Pack 1
Horns (SoundCV9):
CV163=0 Nathan K-5LLA-R1L
CV163=1 Nathan K-5LLA-R1L (2nd Gen)
CV163=2 Nathan K-5LLA-R1L (3rd Gen)
CV163=3 Nathan K-5LLA-R1L Ed2
CV163=4 Nathan K-5LLA-R1L (2nd Gen) Ed2
CV163=5 Nathan K-5LLA-R1L (3rd Gen) Ed2
CV163=6 Nathan K-5LLA-R1L Ed3
CV163=7 Nathan K-5HL-R2 Ed2
CV163=8 Nathan K-5HL-R2 (3rd Gen)
CV163=9 Nathan K-5HL-R2 (2nd Gen)
CV163=10 Nathan K-5LA-R24
EMD 3rd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 049
CV164=1 EMD 8475495 Steel Bell 066
CV164=2 EMD 8475495 Steel Bell 068
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4
S0822 - Release Notes
===================================================
V-2 R-2:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- new horn pack "SD70ACE/SD70M-2 Horn Pack 1"
- new smart start timer update Hide description more…
The EMD SD90MAC is a model of 6,000 hp (4,470 kW)[1] C-C diesel-electric locomotive produced by General Motors Electro-Motive Division. It is, with the SD80MAC, one of the largest single-engined locomotives produced by EMD, surpassed only by the dual-engined DDA40X.
The SD9043MAC is the 4,300 hp (3,210 kW) variant, using a 16-cylinder 710G engine instead of the H-engine, which was originally intended as a temporary alternative while EMD tried to solve the H-engine's issues. However, the accompanying upgrade program was never utilized by its customers.
The SD90MAC's features include radial steering trucks with AC traction motors and an isolated safety cab which is mounted on shock absorbers to lessen vibrations in the cab. The SD90MAC, like the SD80MAC, SD70ACe, and SD70M-2, has a wide radiator section, nearly the entire width of the locomotive, which along with their size makes them easy to spot.
As of 2019, some SD90MACs are still in service on the Union Pacific. Norfolk Southern had rostered 110 SD90MAC locomotives purchased or traded from Union Pacific or the CIT Group respectively, that have now all been rebuilt as EMD SD70ACU locomotives. Canadian Pacific has also opted to convert their small fleet of long-stored SD90MACs into SD70ACUs as well.
This would be correct for the following locomotives:
SD70, SD70M, SD90/43MAC, SD70I,
Though recorded from an SD79043MAC it would be very close to the following locomotives:
SD50AF, GP60, GP60M, GP60B, SD60, SD60M, SD60I, SD60F, SD75M, SD75I, Austrailian National AN Class, SD70MAC, SD50X, GT46C, SD60E (upgraded to 710G3B from 710G3A)and others...
Recorded from a EMD SD9043MAC
This project is an isolation switch based low idle version. It has a single turbo late (silenced) exhaust stack.
File also contains a "low Idle" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to go to "regular idle" and begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
3rd Generation Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie RS-3L
CV163=1 Leslie RS-5T-RRO
CV163=2 Nathan K-2H
CV163=3 Nathan K-3HL
CV163=4 Nathan K-3L
CV163=5 Nathan K-3LA
CV163=6 Nathan K-5HL-R2
CV163=7 Nathan K-5H-R24
CV163=8 Nathan K-5L
CV163=9 Nathan K-5LA
CV163=10 Nathan K-5LA-R24
CV163=11 Nathan K-5LLA-R1L
CV163=12 Nathan K-5L-R24
CV163=13 Nathan P-3
CV163=14 Nathan P-5-R24
EMD 3rd Generation Bell Template Pack 3
Bells (SoundCV10):
CV164=0 Ekyrail E-Bell 001
CV164=1 UKM B443 Steel Bell 001
CV164=2 EMD 8475495 Steel Bell 068
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4
S0844 - Release Notes
===================================================
V-4 R-4:
===================================================
- New Prime Mover Volume Mode Hide description more…
The EMD 645 family of diesel engines were designed and manufactured by the Electro-Motive Division of General Motors. The 645 series was an evolution of the earlier 567 series and a precursor to the later 710 series. The 645 series engines entered production in 1965. All 645 engines utilize forced induction, with either a Roots blower or a turbocharger. The 645 series has a maximum engine speed of between 900 and 950 revolutions per minute (rpm), an increase over the 800 to 900 rpm maximum speed for the 567 series.
While only a few operating examples exist today, the 20cyl 645E3 was often found in the following locomotives:
SD45, F45, FP45, SD45X, SDP45, SD45T-2, SD45-2, and others
Recorded from a EMD SD45T-2
This project is a reverser based low idle version. It has a single turbo early exhaust stack.
File also contains a "low Idle" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to go to "regular idle" and begin moving.
Another "low Idle" Mode is reverser in center position. When pressing F24 while stopped, you can throttle through the notches like the prototype in neutral. F24 must be turned off to go to "regular idle" and begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
2nd Generation Horn Pack 2
Horns (SoundCV9):
CV163=0 Leslie S-3L
CV163=1 Nathan K-3HA
CV163=2 Nathan K-5H-R24
CV163=3 Nathan K-5L
CV163=4 Nathan K-5LA-R23
CV163=5 Nathan K-5LA-R24
CV163=6 Nathan M-5
CV163=7 Nathan P-2-R2
CV163=8 Nathan P-3 Ed2
CV163=9 Nathan P-3-OC
CV163=10 Nathan P-3-OC Ed2
CV163=11 Nathan P-5
CV163=12 Nathan P-5-OC
CV163=13 Nathan P-5-R24-OC
CV163=14 Prime PM-920
CV163=15 Prime PM-990
EMD 2nd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 004
CV164=1 EMD 8004156 Bronze Bell 004
CV164=2 EMD 8475495 Steel Bell 005
CV164=3 EMD 8004156 Bronze Bell 010
CV164=4 EMD 8475495 Steel Bell 015
CV164=5 UKM B443 Steel Bell 002
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV165=1 Cast Iron Shoe
EMD 2nd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 SD40-2 Air Dryer 1
CV166=1 SD40-2 Air Dryer 2
CV166=2 SD40-2 Air Dryer 3
CV166=3 SD40-2 Air Dryer 4
S0707 - Release Notes
===================================================
V-4 R-4:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- new prime mover Hide description more…
The EMD 645 family of diesel engines were designed and manufactured by the Electro-Motive Division of General Motors. The 645 series was an evolution of the earlier 567 series and a precursor to the later 710 series. The 645 series engines entered production in 1965. All 645 engines utilize forced induction, with either a Roots blower or a turbocharger. The 645 series has a maximum engine speed of between 900 and 950 revolutions per minute (rpm), an increase over the 800 to 900 rpm maximum speed for the 567 series.
While only a few operating examples exist today, the 20cyl 645E3 was often found in the following locomotives:
SD45, F45, FP45, SD45X, SDP45, SD45T-2, SD45-2, and others
Recorded from a EMD SD45T-2
This project has a notch based low idle. It has a single turbo late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
2nd Generation Horn Pack 3
Horns (SoundCV9):
CV163=0 Leslie RS-3L
CV163=1 Leslie S-3K-R
CV163=2 Leslie SL-4T
CV163=3 Nathan K-3L
CV163=4 Nathan K-3LA
CV163=5 Nathan K-5H
CV163=6 Nathan K-5H-R24
CV163=7 Nathan K-5L
CV163=8 Nathan K-5LA
CV163=9 Nathan K-5LA-R24
CV163=10 Nathan M-5
CV163=11 Nathan P-3
CV163=12 Nathan P-5
CV163=13 Nathan P-5A
CV163=14 Nathan P-5A-OC
EMD 2nd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 004
CV164=1 EMD 8004156 Bronze Bell 004
CV164=2 EMD 8475495 Steel Bell 005
CV164=3 EMD 8004156 Bronze Bell 010
CV164=4 EMD 8475495 Steel Bell 015
CV164=5 UKM B443 Steel Bell 002
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV165=1 Cast Iron Shoe
EMD 2nd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 SD40-2 Air Dryer 1
CV166=1 SD40-2 Air Dryer 2
CV166=2 SD40-2 Air Dryer 3
CV166=3 SD40-2 Air Dryer 4
S0851 - Release Notes
===================================================
V-1 R-1:
===================================================
- notch based low idle version of S0707 project Hide description more…
The SD80MAC is a 5000 horsepower C-C diesel-electric locomotive. The SD80MAC uses a 20 cylinder version of EMD's 710G prime mover,formally known as the V-20 710G3B-ES and is the first diesel locomotive to use a 20-cylinder engine since the SD45/SD45-2. The SD80MAC introduced a wide radiator housing similar to GE locomotives and the placement of dynamic brakes at the rear of the locomotive. Key spotting difference between the SD80MAC and SD90MAC include: no external rear sandbox on the 90MAC, rear number boards, and the placement of the front numberboards (above the cab windows on the SD80MAC, on the nose on most SD90MACs). The SD80MAC also has recessed red marker lights in the nose, an identifying feature unique to Conrail locomotives, although NS has removed the lights on most of their former Conrail engines.
We've tried to be as prototypical as possible with this iconic locomotive. Because of this, the notching on this SD80MAC file may be slightly different from what you are used to. Like many modern EMDs there is a warm-up cycle when you initially turn on the prime mover. This will cause the prime mover to rise and hold for a short period of time. There is also a high and low idle dictated by the isolation switch. If the isolation switch is not activated Notch 1 and Notch 2 are the same as this is high idle. Activating the islolation switch will drop the sounds to low idle.
Recorded from a EMD SD80MAC
This project is an isolation switch based low idle version. It has a single turbo late (silenced) exhaust stack.
File also contains a "low Idle" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to go to "regular idle" and begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
3rd Generation Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie RS-3L
CV163=1 Leslie RS-5T-RRO
CV163=2 Nathan K-2H
CV163=3 Nathan K-3HL
CV163=4 Nathan K-3L
CV163=5 Nathan K-3LA
CV163=6 Nathan K-5HL-R2
CV163=7 Nathan K-5H-R24
CV163=8 Nathan K-5L
CV163=9 Nathan K-5LA
CV163=10 Nathan K-5LA-R24
CV163=11 Nathan K-5LLA-R1L
CV163=12 Nathan K-5L-R24
CV163=13 Nathan P-3
CV163=14 Nathan P-5-R24
EMD 3rd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 049
CV164=1 EMD 8475495 Steel Bell 066
CV164=2 EMD 8475495 Steel Bell 068
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV165=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4
S0596 - Release Notes
===================================================
V-4 R-4:
===================================================
- remastered prime mover
- new prime mover volume mode
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- updated prime mover comment Hide description more…
The SD80MAC is a 5000 horsepower C-C diesel-electric locomotive. The SD80MAC uses a 20 cylinder version of EMD's 710G prime mover,formally known as the V-20 710G3B-ES and is the first diesel locomotive to use a 20-cylinder engine since the SD45/SD45-2. The SD80MAC introduced a wide radiator housing similar to GE locomotives and the placement of dynamic brakes at the rear of the locomotive. Key spotting difference between the SD80MAC and SD90MAC include: no external rear sandbox on the 90MAC, rear number boards, and the placement of the front numberboards (above the cab windows on the SD80MAC, on the nose on most SD90MACs). The SD80MAC also has recessed red marker lights in the nose, an identifying feature unique to Conrail locomotives, although NS has removed the lights on most of their former Conrail engines.
We've tried to be as prototypical as possible with this iconic locomotive. Because of this, the notching on this SD80MAC file may be slightly different from what you are used to. Like many modern EMDs there is a warm-up cycle when you initially turn on the prime mover. This will cause the prime mover to rise and hold for a short period of time. There is also a high and low idle dictated by the isolation switch. If the isolation switch is not activated Notch 1 and Notch 2 are the same as this is high idle. Activating the islolation switch will drop the sounds to low idle.
Recorded from a EMD SD80MAC
This project is an isolation switch based low idle version. It has a single turbo late (silenced) exhaust stack.
File also contains a "low Idle" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to go to "regular idle" and begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
3rd Gen Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie S-3L-R
CV163=1 Leslie S-5T-RRO-R
CV163=2 Nathan K-2H
CV163=3 Nathan K-3H-L
CV163=4 Nathan K-3L
CV163=5 Nathan K-3LA
CV163=6 Nathan K-5HL
CV163=7 Nathan K-5H-R24
CV163=8 Nathan K-5L
CV163=9 Nathan K-5LA
CV163=10 Nathan K-5LA-R24
CV163=11 Nathan K-5L-LA
CV163=12 Nathan K-5L-R24
CV163=13 Nathan P-3
CV163=14 Nathan P-5-R24
CV163=15 Leslie RS-3L-RO
EMD 3rd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 049
CV164=1 EMD 8475495 Steel Bell 066
CV164=2 EMD 8475495 Steel Bell 068
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4 Hide description more…
The EMD 567 family of Prime Mover was one of the most widely used in the world! From F-Units to Geeps this popular power house can still be found in many locomotives riding the rails today. Our EMD 6cyl version of the 567A would be appropriate for the following locomotives:
SW-1
Although the following locomotives used a slightly different variation of the EMD 6cyl 567, our sound file would be acceptable in the following as well:
SW-600
Recorded from a EMD SW1
This project is a normal idle version. It is an air throttle version. It has switcher type exhaust with a single exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
1st Generation Switcher Horn Pack 1
Horns (SoundCV9):
CV163=0 Handcock 4700 Whistle (Temp No Loop)
CV163=1 Leslie A-125
CV163=2 Leslie A-200
CV163=3 Leslie S-25 (Temp Leslie S-2M)
CV163=4 Leslie S-2M
CV163=5 Leslie S-3K
CV163=6 Leslie S-3L
CV163=7 Nathan M-3
CV163=8 Nathan M-5
CV163=9 Nathan P-2 (Temp Nathan P-3-OC)
CV163=10 Nathan P-3-OC
CV163=11 Nathan P-5-OC
CV163=12 Wabco A2
CV163=13 Wabco AA-2 (Temp Wabco A2)
CV163=14 Wabco E-2
EMD 1st Generation Switcher Bell Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8004156 Bronze Bell 007
CV164=1 EMD 8475495 Steel Bell 011
CV164=2 EMD 8004156 Bronze Bell 008
CV164=3 EMD 8475495 Steel Bell 034
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
Switcher Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Cast Iron Shoe #1
EMD 1st Generation Switcher Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 NW2 Air Dryer 1
CV166=1 NW5 Air Dryer 1
CV166=2 SW7 Air Dryer 1
CV166=3 SW10 Air Dryer 1 Hide description more…
The EMD 567 family of Prime Mover was one of the most widely used in the world! From F-Units to Geeps this popular power house can still be found in many locomotives riding the rails today. Our EMD 8cyl version of the 567 would be appropriate for the following locomotives:
SW8, SW900, G8, GA8, GL8, JL8, And others.....
Recorded from a EMD SW8
This project is a normal idle version. It is an air throttle version. It has switcher type exhaust with a single exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
1st Generation Switcher Horn Pack 1
Horns (SoundCV9):
CV163=0 Handcock 4700 Whistle (Temp No Loop)
CV163=1 Leslie A-125
CV163=2 Leslie A-200
CV163=3 Leslie S-25 (Temp Leslie S-2M)
CV163=4 Leslie S-2M
CV163=5 Leslie S-3K
CV163=6 Leslie S-3L
CV163=7 Nathan M-3
CV163=8 Nathan M-5
CV163=9 Nathan P-2 (Temp Nathan P-3-OC)
CV163=10 Nathan P-3-OC
CV163=11 Nathan P-5-OC
CV163=12 Wabco A2
CV163=13 Wabco AA-2 (Temp Wabco A2)
CV163=14 Wabco E-2
EMD 1st Generation Switcher Bell Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8004156 Bronze Bell 007
CV164=1 EMD 8475495 Steel Bell 011
CV164=2 EMD 8004156 Bronze Bell 008
CV164=3 EMD 8475495 Steel Bell 034
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
Switcher Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Cast Iron Shoe #1
EMD 1st Generation Switcher Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 NW2 Air Dryer 1
CV166=1 NW5 Air Dryer 1
CV166=2 SW7 Air Dryer 1
CV166=3 SW10 Air Dryer 1 Hide description more…
If you download the designated file, you agree to be legally bound by the license given above.