")}("width","220px",["/lib/bootstrap-select/css/bootstrap-select.min.css"],"rel=\u0022stylesheet\u0022 ");
The EMD 645 family of diesel engines were designed and manufactured by the Electro-Motive Division of General Motors. The 645 series was an evolution of the earlier 567 series and a precursor to the later 710 series. The 645 series engines entered production in 1965. All 645 engines utilize forced induction, with either a Roots blower or a turbocharger. The 645 series has a maximum engine speed of between 900 and 950 revolutions per minute (rpm), an increase over the 800 to 900 rpm maximum speed for the 567 series.
Our 12cyl 645E variation is appropriate for the following locomotives:
GP15-1, GP15AC, SW-1500, SW-1504, MP15AC, MP15DC
Recorded from a EMD MP15AC
This project is a normal idle version. It has switcher type exhaust with 2 exhaust stacks.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
2nd Generation Switcher Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie A-125
CV163=1 Leslie S-25
CV163=2 Leslie S-3K-R
CV163=3 Leslie S-3L-R
CV163=4 Leslie S-5T-R
CV163=5 Nathan K-3L
CV163=6 Nathan K-3LA
CV163=7 Nathan K-5LA
CV163=8 Nathan M-3H
CV163=9 Nathan P-3
CV163=10 Nathan P-5
CV163=11 Prime PM-920
CV163=12 Prime PM-990
EMD 2nd Generation Switcher Bell Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 008
CV164=1 EMD 8004156 Bronze Bell 006
CV164=2 EMD 8004156 Bronze Bell 033
CV164=3 EMD 8004156 Bronze Bell 036
CV164=4 Graham-White E-Bell 007
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
Switcher Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV166=1 Cast Iron Shoe
EMD 2nd Generation Switcher Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 SW1500 Air Dryer 1
CV166=1 SW1500 Air Dryer 2
CV166=2 SW1500 Air Dryer 3
CV166=3 MP15DC Air Dryer 4 Hide description more…
The EMD 645 family of diesel engines were designed and manufactured by the Electro-Motive Division of General Motors. The 645 series was an evolution of the earlier 567 series and a precursor to the later 710 series. The 645 series engines entered production in 1965. All 645 engines utilize forced induction, with either a Roots blower or a turbocharger. The 645 series has a maximum engine speed of between 900 and 950 revolutions per minute (rpm), an increase over the 800 to 900 rpm maximum speed for the 567 series.
Locomotives:
GP38, GP38AC, GP38-2, GP38-2L, GP38-2W, SD38, SD38-2, NSWGR 422 Class, Victorian Railways X Class, EMD G26
Recorded from a EMD GP38-2
This project is a normal idle version. It has 2 exhaust stacks.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
2nd Gen Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie S-3K-R
CV163=1 Leslie S-3L-R
CV163=2 Leslie S-5T-F
CV163=3 Leslie S-5T-R
CV163=4 Nathan K-3H
CV163=5 Nathan K-3L
CV163=6 Nathan K-3LA
CV163=7 Nathan K-5H
CV163=8 Nathan K-5LA
CV163=9 Nathan K-5LA-R24
CV163=10 Nathan M-3
CV163=11 Nathan M-3H
CV163=12 Nathan P-3
CV163=13 Nathan P-5-R24
EMD 2nd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 004
CV164=1 EMD 8004156 Bronze Bell 004
CV164=2 EMD 8475495 Steel Bell 005
CV164=3 EMD 8004156 Bronze Bell 010
CV164=4 EMD 8475495 Steel Bell 015
CV164=5 UKM B443 Steel Bell 002
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV166=1 Cast Iron Shoe
EMD 2nd Generation Air Dryer Template Pack 4
Air Dryer (SoundCV12)
CV166=0 GP38-2 Air Dryer 1
CV166=1 GP38-2 Air Dryer 2
CV166=2 GP38-2 Air Dryer 3
CV166=3 GP38-2 Air Dryer 4 Hide description more…
The EMD 645 family of diesel engines were designed and manufactured by the Electro-Motive Division of General Motors. The 645 series was an evolution of the earlier 567 series and a precursor to the later 710 series. The 645 series engines entered production in 1965. All 645 engines utilize forced induction, with either a Roots blower or a turbocharger. The 645 series has a maximum engine speed of between 900 and 950 revolutions per minute (rpm), an increase over the 800 to 900 rpm maximum speed for the 567 series.
Locomotives:
GP38, GP38AC, GP38-2, GP38-2L, GP38-2W, SD38, SD38-2, NSWGR 422 Class, Victorian Railways X Class, EMD G26
Recorded from a EMD SD38-2
This project is a normal idle version. It has 2 exhaust stacks.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
2nd Gen Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie S-3K-R
CV163=1 Leslie S-3L-R
CV163=2 Leslie S-5T-F
CV163=3 Leslie S-5T-R
CV163=4 Nathan K-3H
CV163=5 Nathan K-3L
CV163=6 Nathan K-3LA
CV163=7 Nathan K-5H
CV163=8 Nathan K-5LA
CV163=9 Nathan K-5LA-R24
CV163=10 Nathan M-3
CV163=11 Nathan M-3H
CV163=12 Nathan P-3
CV163=13 Nathan P-5-R24
EMD 2nd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 004
CV164=1 EMD 8004156 Bronze Bell 004
CV164=2 EMD 8475495 Steel Bell 005
CV164=3 EMD 8004156 Bronze Bell 010
CV164=4 EMD 8475495 Steel Bell 015
CV164=5 UKM B443 Steel Bell 002
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV166=1 Cast Iron Shoe
EMD 2nd Generation Air Dryer Template Pack 4
Air Dryer (SoundCV12)
CV166=0 GP38-2 Air Dryer 1
CV166=1 GP38-2 Air Dryer 2
CV166=2 GP38-2 Air Dryer 3
CV166=3 GP38-2 Air Dryer 4 Hide description more…
The ALCO 539 engine was developed in response to the perceived drawback that ALCO's line of diesel switchers had a restricted field of vision because of the high hood. Both Baldwin and EMC were offering diesel switchers with a lower engine hood that the trainmen could see over.
The 539T was equipped with the Buchi turbocharger, being made under license by the Elliott Manufacturing Company of Jeannette, Pennsylvania. The first 539T engines were used in S-2 switchers and DL-105 passenger locomotives built in September 1940.
ALCO Locomotives:
S-2, S-4, RS-1, RSC-1, RSD-1, DL-105, DL-107, DL-108, DL-109, DL-110
MLW Locomotives:
S-2, S-4, S-7, S-12, RS-1, RSC-13
Recorded from a ALCO RS-1
This project is a normal idle version. It is an air throttle version. It has a single exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
1st Generation Switcher Horn Pack 1
Horns (SoundCV9):
CV163=0 Handcock 4700 Whistle
CV163=1 Leslie A-125
CV163=2 Leslie A-200
CV163=3 Leslie S-25
CV163=4 Leslie S-2M
CV163=5 Leslie S-3K
CV163=6 Leslie S-3L
CV163=7 Nathan M-3
CV163=8 Nathan M-5
CV163=9 Nathan P-2 (Temp Nathan P-3-OC)
CV163=10 Nathan P-3-OC
CV163=11 Nathan P-5-OC
CV163=12 Wabco A2
CV163=13 Wabco AA-2 (Temp Wabco A2)
CV163=14 Wabco E-2
ALCO Bell Template Pack 3
Bells (SoundCV10):
CV164=0 ALCO Bronze Bell 004
CV164=1 ALCO Bronze Bell 007
CV164=2 ALCO Bronze Bell 009
CV164=3 ALCO Bronze Bell 012
CV164=4 ALCO Bronze Bell 013
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
Switcher Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Cast Iron Shoe #1
ALCO Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 S-1 Air Dryer 1
CV166=1 C-425 Air Dryer 1
CV166=2 RS-18 Air Dryer 1
CV166=3 RS-18 Air Dryer 2 Hide description more…
Between 1981 and 1983 Chessie rebuilt 67 EMD GP30 locomotives.
These were B&O and C&O GP30 units that went through Chessie's rebuilding program at both the Huntington and Cumberland shops. After rebuilding Chessie did not renumber the units, but CSX decided to give them their own number series once they took ownership.
GP-30Ms were internally rewired with some modular components similar to Dash 2 units. They also recieved new IDAC wheel slip control, D77 traction motors, and cab heaters. The orginal 567D prime mover retained turbocharging, but also recieved 645 Power Assemblies.
Recorded from a EMD GP30M
This project is a normal idle version. It has a single turbo early exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
1st Generation Horn Pack 3
Horns (SoundCV9):
CV163=0 Leslie S-3K-R
CV163=1 Leslie S-3L-R
CV163=2 Leslie S-5T-RRO-R
CV163=3 Leslie SU-3L-R (Temp Leslie S-3L-R)
CV163=4 Nathan K-3H
CV163=5 Nathan K-3L
CV163=6 Nathan K-3LA
CV163=7 Nathan K-5H
CV163=8 Nathan K-5LA-R23
CV163=9 Nathan K-5LA-R24
CV163=10 Nathan P-2 (Temp Nathan P-3)
CV163=11 Nathan P-3
CV163=12 Nathan P-5
CV163=13 Nathan P-5A
CV163=14 Nathan P-5-R24
EMD 1st Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8004156 Bronze Bell 011
CV164=1 EMD 8475495 Steel Bell 007
CV164=2 EMD 8004156 Bronze Bell 012
CV164=3 EMD 8475495 Steel Bell 009
CV164=4 EMD 8004156 Bronze Bell 013
CV164=5 EMD 8475495 Steel Bell 010
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
1st Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV166=1 Cast Iron Shoe
EMD 1st Generation Air Dryer Template Pack 2
Air Dryer (SoundCV12)
CV166=0 GP9 Air Dryer 1
CV166=1 GP9 Air Dryer 2
CV166=1 GP8 Air Dryer 1
CV166=1 CF7 Air Dryer 1 Hide description more…
ATSF had on going rebuild programs for U-boats. After the success of the SF30C, Cleburne took aim at U23B's for rebuilding next. The SF30B is a one of a kind rebuild, which now belongs to Minnesota Commercial. ATSF saw it more effective to purchase new locomotives. The SF30B had many upgrades, the unit's horsepower was increased from 2300 to 3000 hp, as the Cleburne Shops installed a General Electric 7FDL-12F30UX prime mover. The electric systems were modified to Dash 7 standards, and Sentry Wheel Slip capability was added. The original 3,250 gallon fuel tank was kept, however overall capacity was reduced to 2,900 gallons, as a section was used as a retention compartment/tank.
Recorded from THE GE SF30B
This project is a normal idle version. It has a single late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
1st Generation Horn Pack 2
Horns (SoundCV9):
CV163=0 Leslie S-3E
CV163=1 Leslie S-3K-R
CV163=2 Leslie S-3L-R
CV163=3 Leslie S-5T-F
CV163=4 Leslie S-5T-R
CV163=5 Leslie S-5T-RRO
CV163=6 Leslie SL-4T
CV163=7 Nathan K-5LA
CV163=8 Nathan M-3-HR2 (Temp Nathan M-3-H)
CV163=9 Nathan M-3-R1
CV163=10 Nathan M3RT1
CV163=11 Nathan M-5-R24 (Temp Nathan M-5)
CV163=12 Wabco A2
GE U-Boats Bell Template Pack 1
Bells (SoundCV10):
CV164=0 GE M 6731022A Steel Bell 004
CV164=1 GE M 6731022A Steel Bell 005
CV164=2 GE M 6731022A Steel Bell 009
CV164=3 GE M 6731022A Steel Bell 021
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
1st Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Cast Iron Shoe #1
GE U-Boats Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 U23B Air Dryer 1
CV166=1 U23B Air Dryer 2
CV166=2 U30C Air Dryer 1
CV166=3 U36B Air Dryer 1 Hide description more…
The EMD 710 is a line of diesel engines built by Electro-Motive Diesel (EMD). Introduced in 1985, the 710 series replaced the earlier EMD 645 series. Since its introduction, EMD has continually upgraded the 710G diesel engine. Power output has increased from 3,800 horsepower on 1985's 16-710G3A to 4,500 horsepower on 2012's 16-710G3C-T2. Over the production span of certain locomotive models, upgraded engine models have been fitted when these became available. For example, an early 1994-built SD70MAC had a 16-710G3B, whereas a later 2003-built SD70MAC would have a 16-710G3C-T1.
In 2005 EMD was released a Tier 2 710 prime mover for thier upcoming SD70M-2 and SD70ACe models. The SD70M-2 is a DC traction version of the SD70ACe, and the two models are nearly identical in every other respect. Like the SD70ACe, the SD70M-2 models are equipped with the 16-710G3C-T2 prime mover which is rated at 4,300 horsepower. One of the main differences in the SD70M-2/SD70ACes from previous SD70s is the addition of Air Start. This loud burst of air in the start sequence is not present on most earlier EMD locomotives. All SD70M-2s and SD70ACes, except for the ones bought by CITX, are equipped with the Airchime model K5LLA air horn and an electronic bell. Due to this Air Start these locomotives have a period of High Idle just after start up to recharge the air and warm up the locomotive.
Locomotives:
SD70M-2, SD70ACe
Recorded from a Tacoma Rail EMD SD70ACE
This project has a notch based low idle with automatic high idle. It has a single turbo late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
SD70ACE/SD70M-2 Horn Pack 1
Horns (SoundCV9):
CV163=0 Nathan P5
CV163=1 Nathan K5LA
CV163=2 Nathan M3H
CV163=3 Leslie RS-2M
CV163=4 Nathan K3HA
CV163=5 Nathan K3L
CV163=6 Nathan K3H
CV163=7 Nathan K5H
CV163=8 Nathan P5A
CV163=9 Nathan P5 (Old Cast)
CV163=10 Nathan M3RT1
CV163=11 Leslie S3L
CV163=12 Leslie S5T
CV163=13 Nathan K5LR24
CV163=14 Leslie S5TRF
CV163=15 Nathan K5LLA #1
CV163=15 Nathan K5LLA #2
CV163=15 Nathan K5LLA #3
CV163=15 Nathan K5LLA #4
CV163=15 Nathan K5LLA #5
CV163=15 Nathan K5LLA #6 - Default
EMD 3rd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 049
CV164=1 EMD 8475495 Steel Bell 066
CV164=2 EMD 8475495 Steel Bell 068
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4 Hide description more…
The GE FDL-16 prime mover was first used in 1959 in the General Electric U25B locomotive. Over the years little changed in terms of sound until the "Dash-8" series of GE locomotives was introduced. Known for their throaty chug and shaft driven compressor (rather than the more modern “Whoop” electric compressor). There was an interim period following the "U Boats" that began the era in GE called the "Dash-7s". During this time many locos started receiving exhaust silencers and the shape of the exhaust changed to the "Bathtub" type. This created a subtle change in sound. The following GE locomotives used the 16cyl FDL prime mover with this type of configuration.
Locomotives:
B30-7, B36-7, C30-7, C36-7, and others.
The following locomotives would use early 16cyl FDL configurations, but this file would work for them as it is very close. Check your prototype as some of the later “U boats” were upgraded with more modern exhausts. You could also use our 73445/74445 GE 16cyl FDL Early file:
U25B, U28B, U30B, U33B, U36B, U25C, U28C, U28CG, U30C, U30CG, P30CH, U34CH, U33C, U36C
Recorded from a GE B36-7
This project is a normal idle version. It has a single late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
2nd Gen Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie S-3K-R
CV163=1 Leslie S-3L-R
CV163=2 Leslie S-5T-F
CV163=3 Leslie S-5T-R
CV163=4 Nathan K-3H
CV163=5 Nathan K-3L
CV163=6 Nathan K-3LA
CV163=7 Nathan K-5H
CV163=8 Nathan K-5LA
CV163=9 Nathan K-5LA-R24
CV163=10 Nathan M-3
CV163=11 Nathan M-3H
CV163=12 Nathan P-3
CV163=13 Nathan P-5-R24
GE Dash 7 Bell Template Pack 1
Bells (SoundCV10):
CV164=0 GE M 6731022A Steel Bell 001
CV164=1 GE M 6731022A Steel Bell 002
CV164=2 GE M 6731022A Steel Bell 012
CV164=3 GE M 6731022A Steel Bell 013
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV166=1 Cast Iron Shoe
GE Dash 7 Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 B36-7 Air Dryer 1
CV166=1 B30-7 Air Dryer 1
CV166=2 C30-7 Air Dryer 1
CV166=3 C30-7 Air Dryer 2 Hide description more…
The GE U18B was introduced by GE as a branch line roadswitcher in 1973. Easy to spot due to its relatively short length — 54 ft 8 in (16.66 m) — it was the only North American locomotive powered by the 8-cylinder FDL engine.
There were some export locomotives built with this prime mover:
SG10B, U15C, U17C, U20C, and the C18-7i
The U18B was not well recieved as only 5 railroads bought the locomotive, with one railroad only purchasing 1 unit, for total of 163 units produced. The Seaboard Coast Line Railroad (SCL) bought 105 U18Bs, far more than the second-best U.S. customer, the Maine Central Railroad (MEC), which ordered 10. Most of the SCL and MEC U18Bs rode on refurbished Blomberg trucks, recycled from old EMD locomotives, making the U18B even more visually distinct from other GE locomotives.
Recorded from a U18B
This project is a normal idle version. It has a single early exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
1st Generation Horn Pack 2
Horns (SoundCV9):
CV163=0 Leslie S-3E
CV163=1 Leslie S-3K-R
CV163=2 Leslie S-3L-R
CV163=3 Leslie S-5T-F
CV163=4 Leslie S-5T-R
CV163=5 Leslie S-5T-RRO
CV163=6 Leslie SL-4T
CV163=7 Nathan K-5LA
CV163=8 Nathan M-3-HR2 (Temp Nathan M-3-H)
CV163=9 Nathan M-3-R1
CV163=10 Nathan M3RT1
CV163=11 Nathan M-5-R24 (Temp Nathan M-5)
CV163=12 Wabco A2
GE U-Boats Bell Template Pack 2
Bells (SoundCV10):
CV164=0 GE M 6731022A Steel Bell 006
CV164=1 GE M 6731022A Steel Bell 007
CV164=2 GE M 6731022A Steel Bell 010
CV164=3 GE M 6731022A Steel Bell 018
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
1st Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Cast Iron Shoe #1
GE U-Boats Air Dryer Template Pack 2
Air Dryer (SoundCV12)
CV166=0 U18B Air Dryer 1
CV166=1 U18B Air Dryer 2
CV166=2 U18B Air Dryer 3
CV166=3 U18B Air Dryer 4 Hide description more…
The SD80MAC is a 5000 horsepower C-C diesel-electric locomotive. The SD80MAC uses a 20 cylinder version of EMD's 710G prime mover,formally known as the V-20 710G3B-ES and is the first diesel locomotive to use a 20-cylinder engine since the SD45/SD45-2. The SD80MAC introduced a wide radiator housing similar to GE locomotives and the placement of dynamic brakes at the rear of the locomotive. Key spotting difference between the SD80MAC and SD90MAC include: no external rear sandbox on the 90MAC, rear number boards, and the placement of the front numberboards (above the cab windows on the SD80MAC, on the nose on most SD90MACs). The SD80MAC also has recessed red marker lights in the nose, an identifying feature unique to Conrail locomotives, although NS has removed the lights on most of their former Conrail engines.
We've tried to be as prototypical as possible with this iconic locomotive. Because of this, the notching on this SD80MAC file may be slightly different from what you are used to. Like many modern EMDs there is a warm-up cycle when you initially turn on the prime mover. This will cause the prime mover to rise and hold for a short period of time. There is also a high and low idle dictated by the isolation switch. If the isolation switch is not activated Notch 1 and Notch 2 are the same as this is high idle. Activating the islolation switch will drop the sounds to low idle.
Recorded from a EMD SD80MAC
This project is an isolation switch based low idle version. It has a single turbo late (silenced) exhaust stack.
File also contains a "low Idle" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to go to "regular idle" and begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
3rd Gen Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie S-3L-R
CV163=1 Leslie S-5T-RRO-R
CV163=2 Nathan K-2H
CV163=3 Nathan K-3H-L
CV163=4 Nathan K-3L
CV163=5 Nathan K-3LA
CV163=6 Nathan K-5HL
CV163=7 Nathan K-5H-R24
CV163=8 Nathan K-5L
CV163=9 Nathan K-5LA
CV163=10 Nathan K-5LA-R24
CV163=11 Nathan K-5L-LA
CV163=12 Nathan K-5L-R24
CV163=13 Nathan P-3
CV163=14 Nathan P-5-R24
CV163=15 Leslie RS-3L-RO
EMD 3rd Generation Bell Template Pack 2
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 049
CV164=1 EMD 8475495 Steel Bell 066
CV164=2 EMD 8475495 Steel Bell 068
CV164=3 Graham-White E-Bell 006
CV164=4 Graham-White E-Bell 009
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
3rd Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe #1
CV166=1 Composition Shoe #2
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4 Hide description more…
If you download the designated file, you agree to be legally bound by the license given above.