")}("width","220px",["/lib/bootstrap-select/css/bootstrap-select.min.css"],"rel=\u0022stylesheet\u0022 ");
The EMD 645 family of diesel engines were designed and manufactured by the Electro-Motive Division of General Motors. The 645 series was an evolution of the earlier 567 series and a precursor to the later 710 series. The 645 series engines entered production in 1965. All 645 engines utilize forced induction, with either a Roots blower or a turbocharger. The 645 series has a maximum engine speed of between 900 and 950 revolutions per minute (rpm), an increase over the 800 to 900 rpm maximum speed for the 567 series.
Locomotives:
GP38, GP38AC, GP38-2, GP38-2L, GP38-2W, SD38, SD38-2, NSWGR 422 Class, Victorian Railways X Class, EMD G26
Recorded from a EMD GP38-2
This project has a notch based low idle. It has 2 exhaust stacks.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
2nd Generation Horn Pack 8
Horns (SoundCV9):
CV163=0 Leslie RS-5T-RRO Ed2
CV163=1 Leslie RSU-3L-LRO
CV163=2 Leslie RS-3K
CV163=3 Leslie RSL-3L-RO
CV163=4 Leslie S-5T-RRO Ed2
CV163=5 Leslie S-3L-R
CV163=6 IEC-Holden K-3L
CV163=7 IEC-Holden K-3L-R3
CV163=8 Nathan P-3 Ed2
CV163=9 Nathan P-5 Ed2
CV163=10 Nathan K-3HA-R2
CV163=11 Nathan K-3LA-R4
CV163=12 Nathan K-5LA Ed2
CV163=13 Nathan K-5LA-R23 Ed2
CV163=14 Nathan K-5LA-R24 Ed2
EMD 2nd Generation Bell Template Pack 3
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 057
CV164=1 EMD 8004156 Bronze Bell 005
CV164=2 EMD 8004156 Bronze Bell 039
CV164=3 EMD 8475495 Steel Bell 059
CV164=4 EMD 8004156 Bronze Bell 045
CV164=5 UKM B443 Steel Bell 004
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV165=1 Cast Iron Shoe
EMD 2nd Generation Air Dryer Template Pack 4
Air Dryer (SoundCV12)
CV166=0 GP38-2 Air Dryer 1
CV166=1 GP38-2 Air Dryer 2
CV166=2 GP38-2 Air Dryer 3
CV166=3 GP38-2 Air Dryer 4
S0853 - Release Notes
===================================================
V-1 R-1:
===================================================
- new project
V-2 R-2:
===================================================
- air compressor update Hide description more…
The EMD 645 family of diesel engines were designed and manufactured by the Electro-Motive Division of General Motors. The 645 series was an evolution of the earlier 567 series and a precursor to the later 710 series. The 645 series engines entered production in 1965. All 645 engines utilize forced induction, with either a Roots blower or a turbocharger. The 645 series has a maximum engine speed of between 900 and 950 revolutions per minute (rpm), an increase over the 800 to 900 rpm maximum speed for the 567 series.
Locomotives:
GP38, GP38AC, GP38-2, GP38-2L, GP38-2W, SD38, SD38-2, NSWGR 422 Class, Victorian Railways X Class, EMD G26
Recorded from a EMD SD20
This project is a normal idle version. It has 4 exhaust stacks.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
1st Generation Horn Pack 2
Horns (SoundCV9):
CV163=0 Leslie S-3E
CV163=1 Leslie S-3K-R
CV163=2 Leslie S-3L-R
CV163=3 Leslie S-5T-F
CV163=4 Leslie S-5T-R
CV163=5 Leslie S-5T-RRO
CV163=6 Leslie SL-4T
CV163=7 Nathan K-5LA
CV163=8 Nathan M-3-HR2 (Temp Nathan M-3-H)
CV163=9 Nathan M-3-R1
CV163=10 Nathan M3RT1
CV163=11 Nathan M-5-R24 (Temp Nathan M-5)
CV163=12 Wabco A2
EMD 2nd Generation Bell Template Pack 3
Bells (SoundCV10):
CV164=0 EMD 8475495 Bronze Bell 014
CV164=1 EMD 8004156 Steel Bell 013
CV164=2 EMD 8475495 Bronze Bell 015
CV164=3 EMD 8004156 Steel Bell 024
CV164=4 EMD 8475495 Steel Bell 028
CV164=5 Graham-White E-Bell 005
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
1st Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV166=1 Cast Iron Shoe
EMD 1st Generation Air Dryer Template Pack 4
Air Dryer (SoundCV12)
CV166=0 GP10 Air Dryer 1
CV166=1 GP10 Air Dryer 2
CV166=2 SD20 Air Dryer 1
CV166=3 SD20 Air Dryer 2 Hide description more…
The Uceta GP16s were the result of a Seaboard Coast Line rebuild program upgrading GP7, GP9 and GP18 EMD locomotives. Unlike the GP10 program which retained a 567 16cyl prime mover, GP16s recieved 645 power assemblies. A 4 stack exhaust was also applied in most cases. Most ex GP7's had a 16-645BC prime mover. While ex GP9's in many cases had a 16-645C. In some rare cases some GP16's had a new 16-645E prime mover. US Army GP16's had brand new 645E's in them. Check your prototype. Today, many smaller railroads still use GP16s and it was deemed a rather successful program.
Recorded from a EMD GP16
This project is a normal idle version. It has 4 exhaust stacks.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual nothing. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
1st Generation Horn Pack 3
Horns (SoundCV9):
CV163=0 Leslie S-3K-R
CV163=1 Leslie S-3L-R
CV163=2 Leslie S-5T-RRO-R
CV163=3 Leslie SU-3L-R (Temp Leslie S-3L-R)
CV163=4 Nathan K-3H
CV163=5 Nathan K-3L
CV163=6 Nathan K-3LA
CV163=7 Nathan K-5H
CV163=8 Nathan K-5LA-R23
CV163=9 Nathan K-5LA-R24
CV163=10 Nathan P-2 (Temp Nathan P-3)
CV163=11 Nathan P-3
CV163=12 Nathan P-5
CV163=13 Nathan P-5A
CV163=14 Nathan P-5-R24
EMD 1st Generation Bell Template Pack 3
Bells (SoundCV10):
CV164=0 EMD 8004156 Bronze Bell 014
CV164=1 EMD 8475495 Steel Bell 013
CV164=2 EMD 8004156 Bronze Bell 015
CV164=3 EMD 8475495 Steel Bell 024
CV164=4 EMD 8004156 Steel Bell 028
CV164=5 Graham-White E-Bell 005
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
1st Gereration Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV166=1 Cast Iron Shoe
EMD 1st Generation Air Dryer Template Pack 7
Air Dryer (SoundCV12)
CV166=0 GP16 Air Dryer 1
CV166=1 GP16 Air Dryer 2
CV166=1 GP16 Air Dryer 3
CV166=1 GP16 Air Dryer 4 Hide description more…
The EMD 645 series was an evolution of the earlier 567 series and a precursor to the later 710 series. When the 645 prime mover entered production in 1965, a large series of new locomotive models was introduced. The turbocharged version was used in EMD's 40 Series (GP40, SD40 and SD45) in 3,000 horsepower (2,200 kW), sixteen-cylinder form and in 3,600 horsepower (2,700 kW), twenty-cylinder form. EMD also introduced the Roots-blown 38 Series (GP38, SD38) and turbocharged, twelve-cylinder 39 Series (GP39, SD39). All of these locomotive models extensively share common components and subsystems, thereby significantly reducing cost and increasing interchangeability. The GP38-2 and SD40-2 became the most popular models of the series and among the most popular locomotive models ever built.
This 16cyl 645E3 with Turbo sound file would be appropriate for the following locomotives:
GP40, GP40P, GP40P-2, GP40-2, GP40X, SD40X, SD40A, SD45T-2, SD40-2, SD40-2W, SD40-2S, F40C, F40PH, F40PH-2, F40PH-2M, SDP40F, SD40-2F
Export locomotives:
GT26MC, GT26CW, GT26CW-1, GT26CW-2, GT26CU-2
Recorded from a EMD SD40-2
This project is a reverser based low idle version. It has a single turbo early exhaust stack.
File also contains a "low Idle" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to go to "regular idle" and begin moving.
Another "low Idle" Mode is reverser in center position. When pressing F24 while stopped, you can throttle through the notches like the prototype in neutral. F24 must be turned off to go to "regular idle" and begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
2nd Generation Horn Pack 1
Horns (SoundCV9):
CV163=0 Leslie S-3K-R
CV163=1 Leslie RS-3L-R
CV163=2 Leslie S-5T-F
CV163=3 Leslie S-5T-R
CV163=4 Nathan K-3H
CV163=5 Nathan K-3L
CV163=6 Nathan K-3LA
CV163=7 Nathan K-5H
CV163=8 Nathan K-5LA
CV163=9 Nathan K-5LA-R24
CV163=10 Nathan M-3
CV163=11 Nathan M-3H
CV163=12 Nathan P-3
CV163=13 Nathan P-5-R24
EMD 2nd Generation Bell Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 003
CV164=1 EMD 8004156 Bronze Bell 003
CV164=2 UKM B443 Steel Bell 001
CV164=3 Graham-White E-Bell 004
CV164=4 Transtronic E-Bell 001
CV164=5 WC Hayes 0333 M-Bell 001
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV165=1 Cast Iron Shoe
EMD 2nd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 SD40-2 Air Dryer 1
CV166=1 SD40-2 Air Dryer 2
CV166=2 SD40-2 Air Dryer 3
CV166=3 SD40-2 Air Dryer 4
S0710 - Release Notes
===================================================
V-14 R-12:
===================================================
- New Prime Mover Volume Mode Hide description more…
The EMD 645 series was an evolution of the earlier 567 series and a precursor to the later 710 series. When the 645 prime mover entered production in 1965, a large series of new locomotive models was introduced. The turbocharged version was used in EMD's 40 Series (GP40, SD40 and SD45) in 3,000 horsepower (2,200 kW), sixteen-cylinder form and in 3,600 horsepower (2,700 kW), twenty-cylinder form. EMD also introduced the Roots-blown 38 Series (GP38, SD38) and turbocharged, twelve-cylinder 39 Series (GP39, SD39). All of these locomotive models extensively share common components and subsystems, thereby significantly reducing cost and increasing interchangeability. The GP38-2 and SD40-2 became the most popular models of the series and among the most popular locomotive models ever built.
This 16cyl 645E3 with Turbo sound file would be appropriate for the following locomotives:
GP40, GP40P, GP40P-2, GP40-2, GP40X, SD40X, SD40A, SD45T-2, SD40-2, SD40-2W, SD40-2S, F40C, F40PH, F40PH-2, F40PH-2M, SDP40F, SD40-2F
Export locomotives:
GT26MC, GT26CW, GT26CW-1, GT26CW-2, GT26CU-2
Recorded from a EMD SD40-2
This project is a normal idle version. It has a single turbo early exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
2nd Generation Horn Pack 5
Horns (SoundCV9):
CV163=0 Leslie RS-3L-R
CV163=1 Leslie RS-3K-R
CV163=2 Leslie RS-5T-R
CV163=3 Leslie RS-5T-RF
CV163=4 Nathan K-3LA-R1
CV163=5 Nathan K-3HA-R1
CV163=6 Nathan K-3H-R1
CV163=7 Nathan P-3-R1
CV163=8 Nathan K-3L-R3
CV163=9 Nathan K-3LA-R4
CV163=10 Nathan K-3HA-R2
CV163=11 Nathan P-3-R4
CV163=12 Nathan K-3HA-R4
CV163=13 Nathan K-5LA-R35
CV163=14 Nathan K-5LA-R45
EMD 2nd Generation Bell Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 003
CV164=1 EMD 8004156 Bronze Bell 003
CV164=2 UKM B443 Steel Bell 001
CV164=3 Graham-White E-Bell 004
CV164=4 Transtronic E-Bell 001
CV164=5 WC Hayes 0333 M-Bell 001
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV165=1 Cast Iron Shoe
EMD 2nd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 SD40-2 Air Dryer 1
CV166=1 SD40-2 Air Dryer 2
CV166=2 SD40-2 Air Dryer 3
CV166=3 SD40-2 Air Dryer 4
S0845 - Release Notes
===================================================
V-2 R-2:
===================================================
- prime mover volume selection mode Hide description more…
The EMD 645 series was an evolution of the earlier 567 series and a precursor to the later 710 series. When the 645 prime mover entered production in 1965, a large series of new locomotive models was introduced. The turbocharged version was used in EMD's 40 Series (GP40, SD40 and SD45) in 3,000 horsepower (2,200 kW), sixteen-cylinder form and in 3,600 horsepower (2,700 kW), twenty-cylinder form. EMD also introduced the Roots-blown 38 Series (GP38, SD38) and turbocharged, twelve-cylinder 39 Series (GP39, SD39). All of these locomotive models extensively share common components and subsystems, thereby significantly reducing cost and increasing interchangeability. The GP38-2 and SD40-2 became the most popular models of the series and among the most popular locomotive models ever built.
This 16cyl 645E3 with Turbo sound file would be appropriate for the following locomotives:
GP40, GP40P, GP40P-2, GP40-2, GP40X, SD40X, SD40A, SD45T-2, SD40-2, SD40-2W, SD40-2S, F40C, F40PH, F40PH-2, F40PH-2M, SDP40F, SD40-2F
Export locomotives:
GT26MC, GT26CW, GT26CW-1, GT26CW-2, GT26CU-2
Recorded from a EMD SD40-2
This project has a notch based low idle. It has a single turbo early exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
2nd Generation Horn Pack 7
Horns (SoundCV9):
CV163=0 Leslie RSL-3L-RO
CV163=1 Leslie RSL-3L-R
CV163=2 Leslie RS-2M-O
CV163=3 Leslie SL-3L
CV163=4 Leslie S-3L-R
CV163=5 Leslie S-5T-R Ed2
CV163=6 IEC-Holden K-3L-R3
CV163=7 Nathan P-3-R4
CV163=8 Nathan P-5A
CV163=9 Nathan P-5 Ed2
CV163=10 Nathan K-3LA-R1
CV163=11 Nathan K-3L-R3
CV163=12 Nathan K-5H Ed2
CV163=13 Nathan K-5LA (NJT)
CV163=14 Nathan K-5LA-R25
EMD 2nd Generation Bell Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 003
CV164=1 EMD 8004156 Bronze Bell 003
CV164=2 UKM B443 Steel Bell 001
CV164=3 Graham-White E-Bell 004
CV164=4 Transtronic E-Bell 001
CV164=5 WC Hayes 0333 M-Bell 001
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV165=1 Cast Iron Shoe
EMD 2nd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 SD40-2 Air Dryer 1
CV166=1 SD40-2 Air Dryer 2
CV166=2 SD40-2 Air Dryer 3
CV166=3 SD40-2 Air Dryer 4
S0850 - Release Notes
===================================================
V-2 R-2:
===================================================
- prime mover volume selection mode Hide description more…
The EMD 645 series engine was an evolution of the earlier 567 series and a precursor to the later 710 series. When the 645 prime mover entered production in 1965, a large series of new locomotive models were introduced. The turbocharged version was used in EMD's 40 Series (GP40, SD40 and SD45) in 3,000 horsepower (2,200 kW), sixteen-cylinder form and in 3,600 horsepower (2,700 kW), twenty-cylinder form. EMD also introduced the Roots-blown 38 Series (GP38, SD38) and turbocharged, twelve-cylinder 39 Series (GP39, SD39). All of these locomotive models extensively share common components and subsystems, thereby significantly reducing cost and increasing interchangeability. The GP38-2 and SD40-2 became the most popular models of the series and among the most popular locomotive models ever built.
This 16cyl 645E3B Turbo sound file would be appropriate for the following locomotives:
SD40-2W, GP40, GP40P, GP40P-2, SD40A, SD45T-2, GP40-2, GP40X, SD40X, SD40-2, F40C, F40PH, F40PH-2, F40PH-2M, SDP40F, SD40-2F
Export locomotives:
GT26MC, GT26CW, GT26CW-1, GT26CW-2, GT26CU-2
Recorded from a F40PHR
This project is a normal idle version. It has a single turbo late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
2nd Generation Horn Pack 8
Horns (SoundCV9):
CV163=0 Leslie RS-5T-RRO Ed2
CV163=1 Leslie RSU-3L-LRO
CV163=2 Leslie RS-3K
CV163=3 Leslie RSL-3L-RO
CV163=4 Leslie S-5T-RRO Ed2
CV163=5 Leslie S-3L-R
CV163=6 IEC-Holden K-3L
CV163=7 IEC-Holden K-3L-R3
CV163=8 Nathan P-3 Ed2
CV163=9 Nathan P-5 Ed2
CV163=10 Nathan K-3HA-R2
CV163=11 Nathan K-3LA-R4
CV163=12 Nathan K-5LA Ed2
CV163=13 Nathan K-5LA-R23 Ed2
CV163=14 Nathan K-5LA-R24 Ed2
EMD 2nd Generation Bell Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 003
CV164=1 EMD 8004156 Bronze Bell 003
CV164=2 UKM B443 Steel Bell 001
CV164=3 Graham-White E-Bell 004
CV164=4 Transtronic E-Bell 001
CV164=5 WC Hayes 0333 M-Bell 001
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV165=1 Cast Iron Shoe
EMD 2nd Generation Air Dryer Template Pack 5
Air Dryer (SoundCV12)
CV166=0 GP40-2 Air Dryer 1
CV166=1 GP40-2 Air Dryer 2
CV166=2 GP40 Air Dryer 1
CV166=3 GP40 Air Dryer 2
S0765 - Release Notes
===================================================
V-3 R-3:
===================================================
- description mispelling fix
- description brake squeal error fix
- soundslot brake squeal spelling mistake
- remastered prime mover
- new horn pack "2nd Generation Pack 8"
V-4 R-4:
===================================================
- Prime mover volume selection mode Hide description more…
The EMD 645 series engine was an evolution of the earlier 567 series and a precursor to the later 710 series. When the 645 prime mover entered production in 1965, a large series of new locomotive models were introduced. The turbocharged version was used in EMD's 40 Series (GP40, SD40 and SD45) in 3,000 horsepower (2,200 kW), sixteen-cylinder form and in 3,600 horsepower (2,700 kW), twenty-cylinder form. EMD also introduced the Roots-blown 38 Series (GP38, SD38) and turbocharged, twelve-cylinder 39 Series (GP39, SD39). All of these locomotive models extensively share common components and subsystems, thereby significantly reducing cost and increasing interchangeability. The GP38-2 and SD40-2 became the most popular models of the series and among the most popular locomotive models ever built.
This 16cyl 645E3B Turbo sound file would be appropriate for the following locomotives:
SD40-2W, GP40, GP40P, GP40P-2, SD40A, SD45T-2, GP40-2, GP40X, SD40X, SD40-2, F40C, F40PH, F40PH-2, F40PH-2M, SDP40F, SD40-2F
Export locomotives:
GT26MC, GT26CW, GT26CW-1, GT26CW-2, GT26CU-2
Recorded from a SD40-2
This project is a reverser based low idle version. It has a single turbo late (silenced) exhaust stack.
File also contains a "low Idle" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to go to "regular idle" and begin moving.
Another "low Idle" Mode is reverser in center position. When pressing F24 while stopped, you can throttle through the notches like the prototype in neutral. F24 must be turned off to go to "regular idle" and begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Recorded from a EMD SD40-2
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
2nd Generation Horn Pack 3
Horns (SoundCV9):
CV163=0 Leslie RS-3L
CV163=1 Leslie S-3K-R
CV163=2 Leslie SL-4T
CV163=3 Nathan K-3L
CV163=4 Nathan K-3LA
CV163=5 Nathan K-5H
CV163=6 Nathan K-5H-R24
CV163=7 Nathan K-5L
CV163=8 Nathan K-5LA
CV163=9 Nathan K-5LA-R24
CV163=10 Nathan M-5
CV163=11 Nathan P-3
CV163=12 Nathan P-5
CV163=13 Nathan P-5A
CV163=14 Nathan P-5A-OC
EMD 2nd Generation Bell Template Pack 1
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 003
CV164=1 EMD 8004156 Bronze Bell 003
CV164=2 UKM B443 Steel Bell 001
CV164=3 Graham-White E-Bell 004
CV164=4 Transtronic E-Bell 001
CV164=5 WC Hayes 0333 M-Bell 001
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV165=1 Cast Iron Shoe
EMD 2nd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 SD40-2 Air Dryer 1
CV166=1 SD40-2 Air Dryer 2
CV166=2 SD40-2 Air Dryer 3
CV166=3 SD40-2 Air Dryer 4
S0775 - Release Notes
===================================================
V-6 R-6:
===================================================
- prime mover volume selection mode Hide description more…
The EMD 645 series engine was an evolution of the earlier 567 series and a precursor to the later 710 series. When the 645 prime mover entered production in 1965, a large series of new locomotive models were introduced. The turbocharged version was used in EMD's 40 Series (GP40, SD40 and SD45) in 3,000 horsepower (2,200 kW), sixteen-cylinder form and in 3,600 horsepower (2,700 kW), twenty-cylinder form. EMD also introduced the Roots-blown 38 Series (GP38, SD38) and turbocharged, twelve-cylinder 39 Series (GP39, SD39). All of these locomotive models extensively share common components and subsystems, thereby significantly reducing cost and increasing interchangeability. The GP38-2 and SD40-2 became the most popular models of the series and among the most popular locomotive models ever built.
This 16cyl 645E3B Turbo sound file would be appropriate for the following locomotives:
SD40-3, SD40-2W, GP40, GP40P, GP40P-2, SD40A, SD45T-2, GP40-2, GP40X, SD40X, SD40-2, F40C, F40PH, F40PH-2, F40PH-2M, SDP40F, SD40-2F
Export locomotives:
GT26MC, GT26CW, GT26CW-1, GT26CW-2, GT26CU-2
This file is made specifically for the use in the CSX SD40-3
These locos were rebuilt with 16cyl 645E3B Prime Movers, had Air Start added, Modern E-Bells, updated Air Dryers, Electric Handbrakes, Smart Start, and other components that made them unique from traditional SD40-2s.
This project has a notch based low idle with automatic high idle. It has a single turbo late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 1 Minute Cycle Engine On & 1 Minute Cycle Engine Off
CV168=2 - 2 Minute Cylcle Engine On & 2 Minute Cycle Engine Off
CV168=3 - 3 Minute Cylcle Engine On & 3 Minute Cycle Engine Off
CV168=4 - 4 Minute Cylcle Engine On & 4 Minute Cycle Engine Off
Etc.....
CV168=255 - 255 Minute Cycle
SD40-3 Horn Pack 1
Horns (SoundCV9):
CV163=0 Nathan K-5LA-R24
CV163=1 Nathan K-5LA (AMTK ALC-42)
CV163=2 Nathan K-5LA-R23
CV163=3 Nathan K-5LA (NJT)
CV163=4 Nathan K-5LA-R35
CV163=5 Nathan K-5LA
CV163=6 Nathan K-5LA (Metra)
CV163=7 Nathan K-5LA-R25
CV163=8 Nathan K-5LA (AMTK ALC-42) Ed2
CV163=9 Nathan K-5LA (MARC)
CV163=10 Nathan K-5LA-R45
SD40-3 Bell Template Pack 1
Bells (SoundCV10):
CV164=0 Graham-White E-Bell 006
CV164=1 Graham-White E-Bell 009
CV164=2 Graham-White E-Bell 001
CV164=3 Graham-White E-Bell 004
CV164=4 Transtronic E-Bell 001
CV164=5 Ekyrail E-Bell 001
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV165=1 Cast Iron Shoe
EMD 3rd Generation Air Dryer Template Pack 1
Air Dryer (SoundCV12)
CV166=0 GP60 Air Dryer 1
CV166=1 SD60E Air Dryer 2
CV166=2 SD70M-2 Air Dryer 3
CV166=3 SD70MAC Air Dryer 4
S0846 - Release Notes
===================================================
V-3 R-3:
===================================================
- Prime mover volume selection mode
V-4 R-4:
===================================================
- Smart start ms fix
- Smart start timer fix Hide description more…
The EMD 645 series engine was an evolution of the earlier 567 series and a precursor to the later 710 series. When the 645 prime mover entered production in 1965, a large series of new locomotive models were introduced. The turbocharged version was used in EMD's 40 Series (GP40, SD40 and SD45) in 3,000 horsepower (2,200 kW), sixteen-cylinder form and in 3,600 horsepower (2,700 kW), twenty-cylinder form. EMD also introduced the Roots-blown 38 Series (GP38, SD38) and turbocharged, twelve-cylinder 39 Series (GP39, SD39). All of these locomotive models extensively share common components and subsystems, thereby significantly reducing cost and increasing interchangeability. The GP38-2 and SD40-2 became the most popular models of the series and among the most popular locomotive models ever built.
This 16cyl 645E3B Turbo sound file would be appropriate for the following locomotives:
SD40-3, SD40-2W, GP40, GP40P, GP40P-2, SD40A, SD45T-2, GP40-2, GP40X, SD40X, SD40-2, F40C, F40PH, F40PH-2, F40PH-2M, SDP40F, SD40-2F
Export locomotives:
GT26MC, GT26CW, GT26CW-1, GT26CW-2, GT26CU-2
This project has a notch based low idle. It has a single turbo late (silenced) exhaust stack.
File also contains an "Isolation Switch" Mode on F15 when Standing Still.
Pressing F15 while not moving will lower the prime mover and lock the motor. F15 must be turned off to begin moving.
Another Mode is "Reverser In Center Position". When pressing F24 while stopped, the motor will lock so you can throttle through the notches like the prototype in neutral. F24 must be turned off to begin moving.
This project has "Run 8" mode. When turning on F26 with F28 off, the prime mover goes to run 8. Turning off F26 returns the prime mover sounds back to normal mode.
This project has "Coast" mode. When turning on F27 with F28 off, the prime mover goes to idle for coasting purposes. Turning off F27 returns the prime mover sounds back to normal mode.
You can still use F26 and F27 for manual notching. You have to keep both F26 and F27 off before pressing F28 to turn on manual notching. Once F28 is on, you can use F26 to notch up and F27 to notch down. F26, F27, and F28 must be turned off to return to normal mode.
This project has "Load" mode. When turning on F29 with F15, F24, F26, F27, F28 off, the prime mover goes into load mode. While you are using load mode, the prime mover will notch up 1 or more notches based on primary load settings(CV104). The throttle notches up using speed instead of requested speed while using the load feature. F29 must be turned off to return to normal mode.
Prime mover volume selection mode. By default the prime mover has volume dynamics. Meaning idle is soft while notch 8 is loud. This is very prototypical. The next option is volume maxed out. Meaning idle and notch 8 are the same volume. This is more suitable for people who like it loud.
Change the sound configuration of the prime mover sound slot 1
CV31 = 16, CV32 = 1
----------------------
CV263 = 0 Prime Mover Dynamic Volume Control
CV263 = 1 Prime Mover Max Volume
This file is also equipped with a Smart Start feature that cycles the prime mover on and off at intervals of your choice if the throttle is left at Idle and the loco is stopped.
Smart Start (Sound CV14):
CV168=0 No Smart Start Cycle - Default
CV168=1 - 3 Minute Cycle
CV168=2 - 6 Minute Cylcle
CV168=3 - 9 Minute Cylcle
CV168=4 - 12 Minute Cylcle
Etc.....
CV168=255 - 765 Minute Cycle
2nd Generation Horn Pack 5
Horns (SoundCV9):
CV163=0 Leslie RS-3L-R
CV163=1 Leslie RS-3K-R
CV163=2 Leslie RS-5T-R
CV163=3 Leslie RS-5T-RF
CV163=4 Nathan K-3LA-R1
CV163=5 Nathan K-3HA-R1
CV163=6 Nathan K-3H-R1
CV163=7 Nathan P-3-R1
CV163=8 Nathan K-3L-R3
CV163=9 Nathan K-3LA-R4
CV163=10 Nathan K-3HA-R2
CV163=11 Nathan P-3-R4
CV163=12 Nathan K-3HA-R4
CV163=13 Nathan K-5LA-R35
CV163=14 Nathan K-5LA-R45
EMD 2nd Generation Template Pack 3
Bells (SoundCV10):
CV164=0 EMD 8475495 Steel Bell 057
CV164=1 EMD 8004156 Bronze Bell 005
CV164=2 EMD 8004156 Bronze Bell 039
CV164=3 EMD 8475495 Steel Bell 059
CV164=4 EMD 8004156 Bronze Bell 045
CV164=5 UKM B443 Steel Bell 004
Auto Bell:
Many Second and Third Generation locomotives have been fitted with an Automatic Bell that is triggered when the horn is blown. In MANY cases this cannot even be bypassed on modern locos. Before the FRA mandated this feature on new locomotives the bell was of course turned on and off separately. Some locomotives were delivered with a manual bell and have been converted to an automatic bell. This creates a challenge in sound file creation.
We realize that not every loco with a particular prime mover had this feature. As such we have built in an option to turn the feature on and off. We will set the default in the file to be what is most appropriate for the particular file.
To turn the feature OFF - Auto Bell OFF:
1. Remove the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 4
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 0
To turn the feature ON - Auto Bell ON:
1. ADD the Auto bell sound slot from the function mapping chart
CV31 = 16, CV32 = 8
----------------------
CV311 = 12
2. Change the sound configuration of the Auto bell sound slot
CV31 = 16, CV32 = 1
----------------------
CV287 = 1
Auto Bell Timer:
The Bell timer is amount of time the bell will play after the horn if the auto timer is active. The timer is broken down into 1/4 of a second increments.
CV169=4 - 1 Second
CV169=8 - 2 Seconds
CV169=12 - 3 Seconds
CV169=16 - 4 Seconds
CV169=20 - 5 Seconds - Default
Etc...
2nd Generation Brake Squeal Template Pack 1
Brake Squeal (SoundCV11)
CV165=0 Composition Shoe
CV165=1 Cast Iron Shoe
EMD 2nd Generation Air Dryer Template Pack 2
Air Dryer (SoundCV12)
CV166=0 SD40-2 Air Dryer 5
CV166=1 SD40-2 Air Dryer 6
CV166=2 SD40-2 Air Dryer 7
CV166=3 SD40-2 Air Dryer 8
S0848 - Release Notes
===================================================
V-3 R-3:
===================================================
- prime mover volume selection mode Hide description more…
If you download the designated file, you agree to be legally bound by the license given above.