Manufacturer: Sudexpress, Item number: 13447, Version: V3-R4
Instead of equipping electric locomotives with just a diesel power pack (last mile package), which enables them to be used independently of the driving current, for example on sidings, Stadler developed the EuroDual, which carries a full-fledged diesel engine. The EuroDual, run as the 159 series, runs purely electrically under the 15 kV-16 2/3 Hz system as well as in the AC and DC networks commonly used in France. Depending on the operating mode, traction power between 6150 kW and 7000 kW is available under catenary, the 16-cylinder Caterpillar CAT C175-16 diesel engine has an output of 2800 kW and generates the energy for the six electric traction motors. Depending on the reduction selected by the customer, the locomotive can reach 120 to 160 km/h. In Germany, the HVLE and the leasing company European Loc Pool each procure ten, ITL / Captrain four EuroDual.
Different starting processes can be selected with F1: 1x press button = warm start / press button 2x = false start / press button 3x = cold start
F5 enables the heavy load mode: The diesel notch is always one up compared with normal operation. If you want to jump two notches, simply set CV 104 to 170 (instead of 150).
F27 turns on the manual ntoching. Once F28 is on, you can use F28 to notch up and F29 to notch down. F27, F28, and F29 must be turned off to return to normal mode. If F27 is off and you press F28, the prime mover will run to full speed.
F17 will bring the locomotive to full stop.
Key | Functions | Sound slots | Volume CVs | Volume values |
---|---|---|---|---|
F0 | front light | |||
F1 | Driving noise on/off (diesel mode), fan motor on as required with F7 | 1, 2, 28 | 259, 267, 475 | 255, 255, 140 |
F2 | air horn (high) | 3 | 275 | 255 |
F3 | air horn (low) | 4 | 283 | 255 |
F4 | sound on/off (electric locomotive mode) please press F9 or F 10 first | 23, 28 | 435, 475 | 100, 140 |
F5 | heavy load | 32 | 507 | 110 |
F6 | acceleration/brake time, shunting mode/shunting speed | |||
F7 | Diesel engine fan /delayed switch-off - not in e-mode | |||
F8 | High beam (depending on direction of travel) | |||
F9 | Panto front | 20, 23, 28 | 411, 435, 475 | 100, 100, 140 |
F10 | Panto rear | 21, 23, 28 | 419, 435, 475 | 100, 100, 140 |
F11 | Activate driver's cab (during commissioning or when changing) | 30 | 491 | 30 |
F12 | coupler clank | 8 | 315 | 90 |
F13 | Cab light (directional) | |||
F14 | apply locomotive brake/locomotive brake release (automaticly) | 13 | 355 | 100 |
F15 | Radio communication #1 | 26 | 459 | 200 |
F16 | curve squeal | 15 | 371 | 115 |
F17 | brake function 1 (Train is slowly braked to a standstill.) | 25 | 451 | 125 |
F18 | horn high/ low | 3, 4 | 275, 283 | 255, 255 |
F19 | Drive Hold - here, driving noise (engine speed) and speed are decoupled from each other. | |||
F20 | Turn off Red Head lights (directional) | |||
F21 | Rail clank | 17 | 387 | 95 |
F22 | sanding | 11 | 339 | 65 |
F23 | release/set train brake | 16 | 379 | 108 |
F24 | compressor | 6 | 299 | 80 |
F25 | compressed air let off | 18 | 395 | 65 |
F26 | sound fader | |||
F27 | manual notching logic on/off | 27 | 467 | 0 |
F28 | manual notching up | |||
F29 | manual notching down | |||
F30 | disable brake squeal sound | |||
F31 | Driver's cab door open/closed | 12 | 347 | 85 |
Make sure that index CV31 is set to 16 and index CV32 is set to 1 before changing a volume CV.