The dieselhydraulic V100 (1968 BR 110 – 115, ab 1992 BR 201 – 204, 293) had been developed by VEB Lokomotivbau „Karl Marx“ for GDR state railway DR for multi purpose service on main and branch lines. The traction motors delivered 1000 HP at 1500 rpm and enabled the loco to reach a maximum speed of 100 km/h. The turbocharged engine 12 KVD 21 SVW is similar to the motor of V180/V100.
.
Different starting processes can be selected with F1:
1x press button = warm start / press button 2x = false start / press button 3x = cold start
Heavy load operation:
F5 - Activates heavy load operation. The acceleration now takes noticeably longer and the diesel engine work harder.
Additional sound selectable via CV169:
F9 - Sanding valve = 0 / Wheel flange lubrication = 1 / Windshield wipers = 2 / Safety valve (Auxiliary brake) = 3 / Safety drive circuit (Indusi) = 4
Coast/Idle operation:
F12 - Activates Coast/idle operation. The engine speed goes to Coast/idle. This simulates, for example, a downhill ride or rolling without a trailer load.
Braking functions:
F17 - Brake function 1. The locomotive slowly brakes to a standstill with the sound of the brake valve.
Deactivate braking Sound:
F27 - Deactivates brake squeal Sound when the train stops. (4 different brake squeal sounds with CV162 value 0-3 selectable)
Key | Functions | Sound slots | Volume CVs | Volume values |
---|---|---|---|---|
F0 | front light | |||
F1 | sound on/off | 1, 2, 5, 22 | 259, 267, 291, 427 | 170, 130, 128, 100 |
F2 | air horn | 3 | 275 | 255 |
F3 | bell | 24 | 443 | 128 |
F4 | radiator fan | 4 | 283 | 125 |
F5 | heavy load | |||
F6 | acceleration/brake time, shunting mode/shunting speed | 21 | 419 | 50 |
F7 | radio communication #1 (shunting distance) | 27 | 467 | 160 |
F8 | AUX 1 | |||
F9 | additional sounds CV169: sanding valve = 0 / wheel flange lubrication = 1 / windshield wipers = 2 / safety valve (auxiliary brake) = 3 / safety drive circuit (indusi) = 4 | 11 | 339 | 65 |
F10 | conductor's signal | 10 | 331 | 115 |
F11 | coupler clank | 8 | 315 | 90 |
F12 | coasting | |||
F13 | apply/release locomotive brake (automatically) | 13 | 355 | 90 |
F14 | radio communication #2 | 28 | 475 | 130 |
F15 | ESU smoke generator | |||
F16 | open/close cab door | 12 | 347 | 150 |
F17 | brake function 1 (with brake valve sound) | 25 | 451 | 75 |
F18 | station announcement #1 | 14 | 363 | 150 |
F19 | handbrake | 18 | 395 | 80 |
F20 | radio communication #3 | 23 | 435 | 160 |
F21 | transformer/converter | 32 | 507 | 35 |
F22 | radio communication #4 | 26 | 459 | 160 |
F23 | train heating system (steam heating boiler) | 30 | 491 | 80 |
F24 | compressor #1 | 6 | 299 | 110 |
F25 | station announcement #2 | 20 | 411 | 180 |
F26 | sound fader | |||
F27 | disable brake squeal sound | |||
F28 | apply/release train brake (automatically) | 31 | 499 | 90 |
F29 | compressor #2 | 7 | 307 | 140 |
F30 | compressed air let off | 9 | 323 | 100 |
F31 | switch flange | 19 | 403 | 135 |
Make sure that index CV31 is set to 16 and index CV32 is set to 1 before changing a volume CV.