In 1958 Belgian State Railway NMBS ordered 55 samples of four-axle diesel electric loco from manufacturer Cockerill-Sambre. The locos had been numbered for 201.001-055 (later 5901-5955). The BLW 8-608A motor is an American design and develops 1750 hp. The locos reached a maximum speed of 120 km/h and were used in passenger and freight service till 1988.


Different starting processes can be selected with F1: 1x press button = warm start / press button 2x = false start / press button 3x = cold start

F5 enables the heavy load mode: The diesel notch is always one up compared with normal operation. If you want to jump two notches, simply set CV 104 to 170 (instead of 150).

F27 turns on the manual ntoching. Once F28 is on, you can use F28 to notch up and F29 to notch down. F27, F28, and F29 must be turned off to return to normal mode. If F27 is off and you press F28, the prime mover will run to full speed.

F17 will bring the locomotive to full stop.

KeyFunctionsSound slotsVolume CVsVolume values
F0front light
F1sound on/off1, 22259, 427180, 30
F2air horn (high)3275210
F3air horn (low)4283170
F4radiator fan529190
F5heavy load32507110
F6acceleration/brake time, shunting mode/shunting speed2141950
F7curve squeal1537195
F8AUX#1
F9compressed air let off932370
F10conductor's signal1033195
F11coupler clank831570
F12coasting
F13apply locomotive brake/locomotive brake release (automaticly)1335570
F14announcement #17307235
F15esu smoke generator
F16open/close cab door1234780
F17brake function 125451120
F18announcement #214363235
F19dead-man's vigilance device29483130
F20announcement #320411235
F21switch flange19403125
F22radio communication #1 (shunting distance)26459120
F23radio communication #230491120
F24compressor6299160
F25sanding valve1133945
F26sound fader
F27manual notching logic on/off274670
F28manual notching up
F29manual notching down
F30disable brake squeal sound
F31apply train brake/train brake release (automaticly)3149950

Make sure that index CV31 is set to 16 and index CV32 is set to 1 before changing a volume CV.